Development of ionizing radiation mapping robot /
Radiation mapping can be used to give information regarding the intensity of radiation at a particular location. Mapping of radiation autonomously using robot as agent will help to prevent harm to human especially when radiation related disaster occur. In this project radiation mapping system consi...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
Kuala Lumpur :
Kulliyyah of Engineering, International Islamic University Malaysia,
2017
|
Subjects: | |
Online Access: | Click here to view 1st 24 pages of the thesis. Members can view fulltext at the specified PCs in the library. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
LEADER | 033090000a22003010004500 | ||
---|---|---|---|
008 | 170920s2017 my a f m 000 0 eng d | ||
040 | |a UIAM |b eng |e rda | ||
041 | |a eng | ||
043 | |a a-my--- | ||
050 | 0 | 0 | |a QC795.42 |
100 | 0 | |a Abdul Hafiz bin Zakaria, |e author | |
245 | 1 | |a Development of ionizing radiation mapping robot / |c by Abdul Hafiz bin Zakaria | |
264 | 1 | |a Kuala Lumpur : |b Kulliyyah of Engineering, International Islamic University Malaysia, |c 2017 | |
300 | |a xvii, 120 leaves : |b illustrations ; |c 30cm. | ||
336 | |2 rdacontent |a text | ||
347 | |2 rdaft |a text file |b PDF | ||
502 | |a Thesis (MSMCT)--International Islamic University Malaysia, 2017. | ||
504 | |a Includes bibliographical references (leaves 101-106). | ||
520 | |a Radiation mapping can be used to give information regarding the intensity of radiation at a particular location. Mapping of radiation autonomously using robot as agent will help to prevent harm to human especially when radiation related disaster occur. In this project radiation mapping system consisting of autonomous mobile robot that is equipped with Geiger Muller sensor was developed. A 3D ionizing radiation map is built from the data of the encoder sensor which indicate the location of the mobile robot as well as the radiation data by the Geiger Muller sensor. A grid based algorithm was develop to build the radiation map. The system was tested under several conditions using Cobalt-60 ionizing radiation sources at Malaysia Nuclear Agency indoor radiation facilities. The results shows that the system manage to produce consistent mapping results for repeating experiments with a maximum standard deviation value of 0.9369 µSv/h. This project also evaluated the performance of the Atmel Atmega328 microcontroller under exposure of ionizing radiation Cobalt-60 source. Geant4 software is used to simulate the passage of radiation beams through the Atmel Atmega328 microcontroller model and calculated the estimated absorbed dose rate using Monte Carlo Methods. Microprocessor that is in operation also was tested under the actual ionizing radiation from Cobalt-60 source of with a radiation activity of 0.09 mCi, 0.45 mCi and 2.31 mCi at a distance starting at 20cm and increasing by 20cm until 100cm from the Cobalt-60 source. The test result show that the microcontroller work flawlessly when operating close to source under radiation absorbed dose rate of 28.257 µGy/h. Keywords: Radiation mapping, Autonomous mobile robot, Atmel Atmega328, Geant4, | ||
596 | |a 1 | ||
655 | 7 | |a Theses, IIUM local | |
690 | |a Dissertations, Academic |x Department of Mechatronics Engineering |z IIUM | ||
710 | 2 | |a International Islamic University Malaysia. |b Department of Mechatronics Engineering | |
856 | 4 | |u http://studentrepo.iium.edu.my/handle/123456789/4647 |z Click here to view 1st 24 pages of the thesis. Members can view fulltext at the specified PCs in the library. | |
900 | |a sbh-aaz-ls-naw | ||
999 | |c 439610 |d 470996 | ||
952 | |0 0 |6 T QC 000795.42 A1352D 2017 |7 0 |8 THESES |9 763456 |a IIUM |b IIUM |c MULTIMEDIA |g 0.00 |o t QC 795.42 A1352D 2017 |p 11100380464 |r 2018-10-02 |t 1 |v 0.00 |y THESIS | ||
952 | |0 0 |6 TS CDF QC 795.42 A1352D 2017 |7 0 |8 THESES |9 856360 |a IIUM |b IIUM |c MULTIMEDIA |g 0.00 |o ts cdf QC 795.42 A1352D 2017 |p 11100380463 |r 2018-10-02 |t 1 |v 0.00 |y THESISDIG |