Design and development of a phase synchronous inverter for microgrid system based on electrostatic generator /

The demand for energy sources of the world is exponentially increasing, which is in turn giving rise to a threatening insufficiency of fossil fuels and gases to be used as energy sources. Beyond this traditional and momentary solution to the energy crisis, the renewable energy-driven electrostatic g...

Full description

Saved in:
Bibliographic Details
Main Author: Tawfikur Rahman (Author)
Format: Thesis
Language:English
Subjects:
Online Access:http://studentrepo.iium.edu.my/handle/123456789/9455
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 046850000a22003850004500
008 190403s2019 my a f m 000 0 eng d
040 |a UIAM  |b eng  |e rda 
041 |a eng 
043 |a a-my--- 
050 1 0 |a TK3105 
100 1 |a Tawfikur Rahman,  |e author  |9 24543 
245 1 |a Design and development of a phase synchronous inverter for microgrid system based on electrostatic generator /  |c by Tawfikur Rahman 
264 1 |a Kuala Lumpur :  |b Kulliyyah of Engineering, International Islamic University Malaysia,  |c 2019 
300 |a xviii, 192 leaves :  |b colour illustrations ;  |c 30cm. 
336 |2 rdacontent  |a text 
337 |2 rdamedia  |a unmediated 
337 |2 rdamedia  |a computer 
338 |2 rdacarrier  |a volume 
338 |2 rdacarrier  |a online resource 
347 |2 rdaft  |a text file  |b PDF 
500 |a Abstracts in English and Arabic. 
501 |a "A thesis submitted in fulfilment of the requirement for the degree of Doctor of Philosophy (Engineering)." --On title page. 
502 |a Thesis (Ph.D)--International Islamic University Malaysia, 2019. 
504 |a Includes bibliographical references (leaves 143-158). 
520 |a The demand for energy sources of the world is exponentially increasing, which is in turn giving rise to a threatening insufficiency of fossil fuels and gases to be used as energy sources. Beyond this traditional and momentary solution to the energy crisis, the renewable energy-driven electrostatic generators provide the scope of a long-term solution. However, the electrostatic generator (ESG) with renewable energy should convert to supply AC for microgrid, but an inversion of the high voltage static DC has suffered many problems, such as inferior quality of waveform, stabilization of the input voltage, high switching loss due to phase synchronize and power quality as well as high unexpected voltage. Furthermore, an electrostatic generator produces high voltage DC and low current which is milliamperes (mA). Therefore, to overcome those issues, a new zero-crossing based voltage source phase synchronous inverter (PSI) circuit has been proposed in the microgrid system, which especially makes the AC waveform, free from higher harmonic distortion, low switching loss, and increased efficiency. A zero-crossing pulse width signal is generated to precisely synchronize with a microgrid line frequency that is done by switching and logic networks. A zero-crossing circuit is utilized to detect the phase with frequency, to make a zero-crossing signal and synchronize the phase angle between inverter and microgrid system. In this study, the unique inverter switching parameters are optimized, such as input source voltage of 10k������������, the duty cycle of 95%, switching frequency 2kHz and a microgrid load of 1000Ω, whereas the other parameters are considered. In addition, an LCL lowpass filter is used to couple between inverter and microgrid system, to convert square wave to pure sinusoidal wave and to reduce the higher harmonic distortion. Both the new proposed design and existing design are simulated by MatLab16.a/Simulink, Or CAD Capture 16.6, Proteus 8 professional and Keysight BenchVue. From this analysis, without the filtering condition and with the filtering condition of total harmonic distortion (THD) is 47.9% to 2.1%, which is approximately a 45% reduction in the higher harmonic distortion. The phase analysis showed that the error of an inverter side phase angle and microgrid side phase angle are 26.34° and 2.54°, respectively. The theoretical, simulated and experimental results have shown that the newly designed inverter has performed better in terms of the overall system conversion efficiency of 96.6%, the phase angle of 2.54, and THD of about 2.1%. The proposed PSI is appropriate for microgrid applications that could contribute to the economic improvement of the country and globally as a whole. 
650 0 |a Microgrids (Smart power grids)   |9 24544 
655 7 |a Theses, IIUM local 
690 |a Dissertations, Academic  |x Kulliyyah of Engineering  |z IIUM 
710 2 |a International Islamic University Malaysia.  |b Kulliyyah of Engineering  |9 4827 
856 4 |u http://studentrepo.iium.edu.my/handle/123456789/9455 
900 |a sz-aaz-nbm 
942 |2 lcc  |c THESIS 
999 |c 439689  |d 473448 
952 |0 0  |1 0  |2 lcc  |4 0  |6 T T K3105 T00234D 02019  |7 3  |8 IIUMTHESIS  |9 762173  |a IIUM  |b IIUM  |c THESIS  |d 2022-11-24  |g 0.00  |o t TK 3105 T234D 2019  |p 11100417967  |r 1900-01-02  |t 1  |v 0.00  |y THESIS 
952 |0 0  |1 0  |2 lcc  |4 0  |6 TS C D F TK 03105 T00234D 02019  |7 3  |8 THESISSOFTCOPY  |9 858155  |a IIUM  |b IIUM  |c THESIS  |d 2022-11-24  |g 0.00  |o ts cdf TK 3105 T234D 2019  |p 11100417968  |r 1900-01-02  |t 1  |v 0.00  |y THESISDIG