Detection of glove defects and development of electrically conducting former

NBR gloves are considered to be one of the most extensively used safety goods worldwide Disposable gloves can be broadly divided into two many areas namely medical-health and non-medical. The gloves provide the necessary barrier protection against bacteria, viruses and chemical penetration. In the m...

Full description

Saved in:
Bibliographic Details
Main Author: Antiring, Andy O'Brien N
Format: Thesis
Published: 2022
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-mmu-ep.12034
record_format uketd_dc
spelling my-mmu-ep.120342024-01-10T09:12:37Z Detection of glove defects and development of electrically conducting former 2022-06 Antiring, Andy O'Brien N TS Manufactures NBR gloves are considered to be one of the most extensively used safety goods worldwide Disposable gloves can be broadly divided into two many areas namely medical-health and non-medical. The gloves provide the necessary barrier protection against bacteria, viruses and chemical penetration. In the midst of the Covid-19 pandemic, it is even more important to wear appropriate gloves to increase protection for frontlines working to control the spread of the Covid-19 virus and resulting diseases. NBR gloves are required in places such as workshops, scientific laboratories, hospitals, farms and factories, gardens and electrical installations. In the current work, three different test methods for the detection of defects namely pinhole, thin spot and thin area in gloves are studied and compared. The test methods are tensile test, water-leak test, and electrical insulation test. Mechanical and dielectric integrities of 4-gram (0.07 mm thickness) nitrile-examination gloves with defects such as sub-mm pinhole and a thin spot in the obscured finger region, as well as a relatively large thin area, are measured and compared. Mechanical test methods were the water-leak test in accordance with the ASTM standard and the tensile test accordance to EN455 standard, normal glove is required to pass the force-at-break of 6 N in the tensile test, but this was significantly reduced (100 V was required to detect glove pinhole defects while in motion. 2022-06 Thesis http://shdl.mmu.edu.my/12034/ http://erep.mmu.edu.my/ masters Multimedia University Faculty of Engineering (FOE) EREP ID: 11738
institution Multimedia University
collection MMU Institutional Repository
topic TS Manufactures
spellingShingle TS Manufactures
Antiring, Andy O'Brien N
Detection of glove defects and development of electrically conducting former
description NBR gloves are considered to be one of the most extensively used safety goods worldwide Disposable gloves can be broadly divided into two many areas namely medical-health and non-medical. The gloves provide the necessary barrier protection against bacteria, viruses and chemical penetration. In the midst of the Covid-19 pandemic, it is even more important to wear appropriate gloves to increase protection for frontlines working to control the spread of the Covid-19 virus and resulting diseases. NBR gloves are required in places such as workshops, scientific laboratories, hospitals, farms and factories, gardens and electrical installations. In the current work, three different test methods for the detection of defects namely pinhole, thin spot and thin area in gloves are studied and compared. The test methods are tensile test, water-leak test, and electrical insulation test. Mechanical and dielectric integrities of 4-gram (0.07 mm thickness) nitrile-examination gloves with defects such as sub-mm pinhole and a thin spot in the obscured finger region, as well as a relatively large thin area, are measured and compared. Mechanical test methods were the water-leak test in accordance with the ASTM standard and the tensile test accordance to EN455 standard, normal glove is required to pass the force-at-break of 6 N in the tensile test, but this was significantly reduced (100 V was required to detect glove pinhole defects while in motion.
format Thesis
qualification_level Master's degree
author Antiring, Andy O'Brien N
author_facet Antiring, Andy O'Brien N
author_sort Antiring, Andy O'Brien N
title Detection of glove defects and development of electrically conducting former
title_short Detection of glove defects and development of electrically conducting former
title_full Detection of glove defects and development of electrically conducting former
title_fullStr Detection of glove defects and development of electrically conducting former
title_full_unstemmed Detection of glove defects and development of electrically conducting former
title_sort detection of glove defects and development of electrically conducting former
granting_institution Multimedia University
granting_department Faculty of Engineering (FOE)
publishDate 2022
_version_ 1794019131575500800