Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin
The human heart produces tiny amount electrical current during each beat. This tiny current is spread through out the human body and is detectable on the human skin. It is possible to record the heart activity by placing electrode on certain parts of the body. The recording of the heart activity is...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2005
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/102688/1/102688.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uitm-ir.102688 |
---|---|
record_format |
uketd_dc |
spelling |
my-uitm-ir.1026882024-12-02T03:38:01Z Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin 2005 Husin, Hafiezf Izzuddin Electric power distribution. Electric power transmission The human heart produces tiny amount electrical current during each beat. This tiny current is spread through out the human body and is detectable on the human skin. It is possible to record the heart activity by placing electrode on certain parts of the body. The recording of the heart activity is called electrocardiogram (ECG) and is represented in graph as voltage over time. In this thesis, the heart activity is extracted from the skin and displayed on the oscilloscope. Hardware is developed to acquire bio-signal on the human skin according to the Einthoven 3 lead method. Einthoven 3 lead method uses to 2 electrodes placed on three combination of location on the human body. The developed hardware consists of amplifier and filters. In contrast to the American Heart Association (AHA) which recommends a cutoff frequency of 100Hz for the low-pass filter; this project utilizes a 40Hz cutoff frequency low-pass filter for noise removal. The ECG signal extracted is compared, calculated its R-R interval for verification. The development of a 3 lead hardware produces an ECG signal that can be used for monitoring purpose. In general, the results ECG displayed from the developed hardware is similar to the ECG signal obtain when using the KENZ ECG machine. 2005 Thesis https://ir.uitm.edu.my/id/eprint/102688/ https://ir.uitm.edu.my/id/eprint/102688/1/102688.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering |
institution |
Universiti Teknologi MARA |
collection |
UiTM Institutional Repository |
language |
English |
topic |
Electric power distribution Electric power transmission |
spellingShingle |
Electric power distribution Electric power transmission Husin, Hafiezf Izzuddin Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
description |
The human heart produces tiny amount electrical current during each beat. This tiny current is spread through out the human body and is detectable on the human skin. It is possible to record the heart activity by placing electrode on certain parts of the body. The recording of the heart activity is called electrocardiogram (ECG) and is represented in graph as voltage over time. In this thesis, the heart activity is extracted from the skin and displayed on the oscilloscope. Hardware is developed to acquire bio-signal on the human skin according to the Einthoven 3 lead method. Einthoven 3 lead method uses to 2 electrodes placed on three combination of location on the human body. The developed hardware consists of amplifier and filters. In contrast to the American Heart Association (AHA) which recommends a cutoff frequency of 100Hz for the low-pass filter; this project utilizes a 40Hz cutoff frequency low-pass filter for noise removal. The ECG signal extracted is compared, calculated its R-R interval for verification. The development of a 3 lead hardware produces an ECG signal that can be used for monitoring purpose. In general, the results ECG displayed from the developed hardware is similar to the ECG signal obtain when using the KENZ ECG machine. |
format |
Thesis |
qualification_level |
Bachelor degree |
author |
Husin, Hafiezf Izzuddin |
author_facet |
Husin, Hafiezf Izzuddin |
author_sort |
Husin, Hafiezf Izzuddin |
title |
Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
title_short |
Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
title_full |
Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
title_fullStr |
Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
title_full_unstemmed |
Development of three lead hardware system for ECG extraction / Hafiezf Izzuddin Husin |
title_sort |
development of three lead hardware system for ecg extraction / hafiezf izzuddin husin |
granting_institution |
Universiti Teknologi MARA (UiTM) |
granting_department |
Faculty of Electrical Engineering |
publishDate |
2005 |
url |
https://ir.uitm.edu.my/id/eprint/102688/1/102688.pdf |
_version_ |
1818588045698400256 |