Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff
Today, SCADA (Supervisory Control and Data Acquisition) system has been widely used in various organizations for the purpose of monitoring and controlling various systems. Telekom Malaysia is one of the organizations that use such system to monitor the condition of pressure level in telephone cables...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
1992
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/104574/1/104574.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uitm-ir.104574 |
---|---|
record_format |
uketd_dc |
spelling |
my-uitm-ir.1045742024-10-10T09:20:17Z Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff 1992 Nik Yusoff, Nik Azleen Apparatus and materials Today, SCADA (Supervisory Control and Data Acquisition) system has been widely used in various organizations for the purpose of monitoring and controlling various systems. Telekom Malaysia is one of the organizations that use such system to monitor the condition of pressure level in telephone cables which is referred to as CGPA (Computer-Based Gas Pressurization Alarm) monitoring system. The system is capable of monitoring and reporting various types of alarm such as pressure and system errors. An of the alarm will be automatically transmitted to the nearest exchange and the headquarter for analysis and rectification. The system is also capable of reporting the pressure level at any point of the cable depending on where me transducers were installed and identity the fault location. The objective of this project is to enhance the existing system software. The software enhancement must be able to eliminate some of the alarms sent to the printer. The alarm to be isolated is the low pressure alarm. Only this critical alarm will be printed out and other alarms will be stored into the hard disk. The software will also be able to page the Telekom personnel via public switched telephone network. This software only need to be active at certain period of the day. 1992 Thesis https://ir.uitm.edu.my/id/eprint/104574/ https://ir.uitm.edu.my/id/eprint/104574/1/104574.pdf text en public advanced_diploma Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Md Zan, Md. Mahfudz |
institution |
Universiti Teknologi MARA |
collection |
UiTM Institutional Repository |
language |
English |
advisor |
Md Zan, Md. Mahfudz |
topic |
Apparatus and materials |
spellingShingle |
Apparatus and materials Nik Yusoff, Nik Azleen Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
description |
Today, SCADA (Supervisory Control and Data Acquisition) system has been widely used in various organizations for the purpose of monitoring and controlling various systems. Telekom Malaysia is one of the organizations that use such system to monitor the condition of pressure level in telephone cables which is referred to as CGPA (Computer-Based Gas Pressurization Alarm) monitoring system. The system is capable of monitoring and reporting various types of alarm such as pressure and system errors. An of the alarm will be automatically transmitted to the nearest exchange and the headquarter for analysis and rectification. The system is also capable of reporting the pressure level at any point of the cable depending on where me transducers were installed and identity the fault location. The objective of this project is to enhance the existing system software. The software enhancement must be able to eliminate some of the alarms sent to the printer. The alarm to be isolated is the low pressure alarm. Only this critical alarm will be printed out and other alarms will be stored into the hard disk. The software will also be able to page the Telekom personnel via public switched telephone network. This software only need to be active at certain period of the day. |
format |
Thesis |
qualification_level |
advanced_diploma |
author |
Nik Yusoff, Nik Azleen |
author_facet |
Nik Yusoff, Nik Azleen |
author_sort |
Nik Yusoff, Nik Azleen |
title |
Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
title_short |
Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
title_full |
Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
title_fullStr |
Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
title_full_unstemmed |
Alarm isolation for Telekom Malaysia CGPA system / Nik Azleen Nik Yusoff |
title_sort |
alarm isolation for telekom malaysia cgpa system / nik azleen nik yusoff |
granting_institution |
Universiti Teknologi MARA (UiTM) |
granting_department |
Faculty of Electrical Engineering |
publishDate |
1992 |
url |
https://ir.uitm.edu.my/id/eprint/104574/1/104574.pdf |
_version_ |
1818588112312336384 |