Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad

Fluorine (F) is known as a reactive species that capable to form a variety of complex defects. It beneficial effect as well as the detrimental effect to the electrical and physical characterization of devices have been studied by many researchers. The effect of F to the electrical results such as re...

Full description

Saved in:
Bibliographic Details
Main Author: Md Saad, Siti Zubaidah
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/12039/1/TM_SITI%20ZUBAIDAH%20MD%20SAAD%20EE%2014_5%201.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.12039
record_format uketd_dc
spelling my-uitm-ir.120392016-05-14T07:22:49Z Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad 2014 Md Saad, Siti Zubaidah Fluorine Metal oxide semiconductors Fluorine (F) is known as a reactive species that capable to form a variety of complex defects. It beneficial effect as well as the detrimental effect to the electrical and physical characterization of devices have been studied by many researchers. The effect of F to the electrical results such as resistance and leakage current has created controversy discussions among researchers. F used as the co-implantation of boron (B) was found to reduce the resistance and leakage current but some researchers revealed an opposite findings. Due to this, it is crucial to understand the phenomenon behind these controversies. This study was done on BiCMOS product. BiCMOS is the Integration of CMOS and Bipolar devices. In this work, we study the effect of F coimplant with BF2 as well as F with B by varying the dose and implant energy in the /?+-region of /?+/n-junction Schottky diode and PMOS as these are the basic and important devices in the BiCMOS technology. Besides that, the most important condition in this experiment was the implant sequence of boron fluoride (BF2) and F co-implant. Instead of implanting F followed by BF2 (F-BF2 sequence), we have reversed the implant sequence to BF2 followed by F (BF2-F sequence). We found that for the same dose and implant energy of F co-implant and BF2, the leakage current of /?+/w-junction was improved by one decade in BF2-F sequence. Further Variation of dose and implant energy had shown that implant sequence affected the electrical characterization such as leakage current, breakdown voltage and resistance in p+/njunction. As implant sequence changes, the pre-amorphization layer will be different according to the dopant, dose and implant energy. These will significantly affect the subsequent implant profile and depth. By implanting B and F as close as possible helps to reduce the leakage current as F acts as a sinker for the defects from End-of- Range (EOR) region to get into the B doped region. While in PMOS, very minor effect of BF2 dose and implant energy Variation upon implant sequence to the SiÜ2 electrical thickness and capacitance were seen as well as to the Negative Bias Temperature Instability (NBTI) degradation except for F Variation effect. With these understandings, integrated circuit (IC) design engineer is able to define the Optimum implant conditions in order to get the desired electrical results such as low leakage current, high breakdown voltage and low NBTI degradation. 2014 Thesis https://ir.uitm.edu.my/id/eprint/12039/ https://ir.uitm.edu.my/id/eprint/12039/1/TM_SITI%20ZUBAIDAH%20MD%20SAAD%20EE%2014_5%201.pdf text en public mphil masters Universiti Teknologi MARA Perpustakaan Tun Abdul Razak
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Fluorine
Metal oxide semiconductors
spellingShingle Fluorine
Metal oxide semiconductors
Md Saad, Siti Zubaidah
Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
description Fluorine (F) is known as a reactive species that capable to form a variety of complex defects. It beneficial effect as well as the detrimental effect to the electrical and physical characterization of devices have been studied by many researchers. The effect of F to the electrical results such as resistance and leakage current has created controversy discussions among researchers. F used as the co-implantation of boron (B) was found to reduce the resistance and leakage current but some researchers revealed an opposite findings. Due to this, it is crucial to understand the phenomenon behind these controversies. This study was done on BiCMOS product. BiCMOS is the Integration of CMOS and Bipolar devices. In this work, we study the effect of F coimplant with BF2 as well as F with B by varying the dose and implant energy in the /?+-region of /?+/n-junction Schottky diode and PMOS as these are the basic and important devices in the BiCMOS technology. Besides that, the most important condition in this experiment was the implant sequence of boron fluoride (BF2) and F co-implant. Instead of implanting F followed by BF2 (F-BF2 sequence), we have reversed the implant sequence to BF2 followed by F (BF2-F sequence). We found that for the same dose and implant energy of F co-implant and BF2, the leakage current of /?+/w-junction was improved by one decade in BF2-F sequence. Further Variation of dose and implant energy had shown that implant sequence affected the electrical characterization such as leakage current, breakdown voltage and resistance in p+/njunction. As implant sequence changes, the pre-amorphization layer will be different according to the dopant, dose and implant energy. These will significantly affect the subsequent implant profile and depth. By implanting B and F as close as possible helps to reduce the leakage current as F acts as a sinker for the defects from End-of- Range (EOR) region to get into the B doped region. While in PMOS, very minor effect of BF2 dose and implant energy Variation upon implant sequence to the SiÜ2 electrical thickness and capacitance were seen as well as to the Negative Bias Temperature Instability (NBTI) degradation except for F Variation effect. With these understandings, integrated circuit (IC) design engineer is able to define the Optimum implant conditions in order to get the desired electrical results such as low leakage current, high breakdown voltage and low NBTI degradation.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Md Saad, Siti Zubaidah
author_facet Md Saad, Siti Zubaidah
author_sort Md Saad, Siti Zubaidah
title Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
title_short Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
title_full Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
title_fullStr Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
title_full_unstemmed Characterization of fluorine upon implant sequence on p-metal oxide semiconductor (PMOS) and P+/N-Junction schottky diode in BiCMOS technology / Siti Zubaidah Md Saad
title_sort characterization of fluorine upon implant sequence on p-metal oxide semiconductor (pmos) and p+/n-junction schottky diode in bicmos technology / siti zubaidah md saad
granting_institution Universiti Teknologi MARA
granting_department Perpustakaan Tun Abdul Razak
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/12039/1/TM_SITI%20ZUBAIDAH%20MD%20SAAD%20EE%2014_5%201.pdf
_version_ 1783733163854397440