Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim

Thermal Energy Storage (TES) system has being established for quite some time and already being used in many places throughout the world. In Malaysia, several places had applied this system as an air-conditioning system in the building. Generally, TES is good for a country because it will normally r...

Full description

Saved in:
Bibliographic Details
Main Author: Kassim, Abdul Hafiz
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/13815/1/13815.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.13815
record_format uketd_dc
spelling my-uitm-ir.138152022-03-30T04:58:16Z Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim 2014-07 Kassim, Abdul Hafiz Universiti Teknologi MARA Production of electric energy or power. Powerplants. Central stations Production of electricity by direct energy conversion Thermal Energy Storage (TES) system has being established for quite some time and already being used in many places throughout the world. In Malaysia, several places had applied this system as an air-conditioning system in the building. Generally, TES is good for a country because it will normally reduce the overall maximum demand by distributing the load but the electricity tariff should be attractive so that the user will get the benefit. In order to make the C2 tariff more attractive, the off-peak energy (kWh) rate must be low enough and maximum demand (kW) rate should be the same with the Cl maximum demand tariff. The purpose of modeling is to be able to simulate the phenomenon between electrical energy (kWh) as the input and refrigerant ton hour (RTh) as the output. With the model, it enables the phenomenon to be predicted. The purpose of optimization is to minimize the input with certain design output or to maximize RTh output with certain energy (kWh) input. The methodology of this study is by calculating the overall cost, using Cl tariff as a benchmark to compare with the C2 tariff. The TES system in Engineering Complex UiTM is being used as the case study. The total costs that involved could be calculated. From this study, it was found that TES system uses more energy and electricity tariff play a very important role to determine its feasibility. The maximum cooling load required is 35,000 RTh with the maximum cooling load demand is 3,500 RT. Considering the optimal usage of 80%, the maximum designed need is 2,880 RT. The study shows that the present tariff set by power utility leads to a conclusion that if the cooling load storage is less than 60% of the total cooling need of a building, it is not feasible to operate TES system. Original TES design was 10,800 RTh, which is 30% which is then not feasible. 2014-07 Thesis https://ir.uitm.edu.my/id/eprint/13815/ https://ir.uitm.edu.my/id/eprint/13815/1/13815.pdf text en public mphil masters Universiti Teknologi MARA Faculty of Electrical Engineering Md. Zain, Zainazlan (Dr. Hj.)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Md. Zain, Zainazlan (Dr. Hj.)
topic Universiti Teknologi MARA
Universiti Teknologi MARA
Production of electricity by direct energy conversion
spellingShingle Universiti Teknologi MARA
Universiti Teknologi MARA
Production of electricity by direct energy conversion
Kassim, Abdul Hafiz
Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
description Thermal Energy Storage (TES) system has being established for quite some time and already being used in many places throughout the world. In Malaysia, several places had applied this system as an air-conditioning system in the building. Generally, TES is good for a country because it will normally reduce the overall maximum demand by distributing the load but the electricity tariff should be attractive so that the user will get the benefit. In order to make the C2 tariff more attractive, the off-peak energy (kWh) rate must be low enough and maximum demand (kW) rate should be the same with the Cl maximum demand tariff. The purpose of modeling is to be able to simulate the phenomenon between electrical energy (kWh) as the input and refrigerant ton hour (RTh) as the output. With the model, it enables the phenomenon to be predicted. The purpose of optimization is to minimize the input with certain design output or to maximize RTh output with certain energy (kWh) input. The methodology of this study is by calculating the overall cost, using Cl tariff as a benchmark to compare with the C2 tariff. The TES system in Engineering Complex UiTM is being used as the case study. The total costs that involved could be calculated. From this study, it was found that TES system uses more energy and electricity tariff play a very important role to determine its feasibility. The maximum cooling load required is 35,000 RTh with the maximum cooling load demand is 3,500 RT. Considering the optimal usage of 80%, the maximum designed need is 2,880 RT. The study shows that the present tariff set by power utility leads to a conclusion that if the cooling load storage is less than 60% of the total cooling need of a building, it is not feasible to operate TES system. Original TES design was 10,800 RTh, which is 30% which is then not feasible.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Kassim, Abdul Hafiz
author_facet Kassim, Abdul Hafiz
author_sort Kassim, Abdul Hafiz
title Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
title_short Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
title_full Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
title_fullStr Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
title_full_unstemmed Modeling and optimization of thermal energy storage system in Engineering Complex, UiTM Shah Alam / Abdul Hafiz Kassim
title_sort modeling and optimization of thermal energy storage system in engineering complex, uitm shah alam / abdul hafiz kassim
granting_institution Universiti Teknologi MARA
granting_department Faculty of Electrical Engineering
publishDate 2014
url https://ir.uitm.edu.my/id/eprint/13815/1/13815.pdf
_version_ 1783733181178970112