Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relativel...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Halim, Muhamad Hazwan
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.14074
record_format uketd_dc
spelling my-uitm-ir.140742022-04-18T04:43:01Z Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim 2015-01 Abdul Halim, Muhamad Hazwan Image processing Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relatively low-cost advantages. The improvement in ultrasound method for fat measurement is not only on the advancement of the ultrasound equipment but also the accuracy of data analysis. Two current issues that have arisen are the influence of protective layer on the accuracy of ultrasonic velocity measurement using A-mode analysis and the B-mode image positioning accuracy due to the application of the predetermined ultrasonic velocity in B-mode imaging. This research implemented new approach in performing the measurement of ultrasonic velocity and ultrasound B-mode analysis. To increase the accuracy of ultrasonic velocity measurement, the thickness of the protective layer was first determined used in ultrasonic velocity measurement. To increase the positioning accuracy of B-mode image, the actual determined velocity was used rather than the predetermined velocity. The improvements made were successful in increasing the accuracy of the ultrasonic velocity measurement and the positioning of the B - mode image. Subsequently, this method was then used to measure intramuscular fat content in chicken fillet. Better correlations between the ultrasound properties (velocity, image histogram mean and percentages of fat pixel) and percentage of fat content measured by Soxhlet Method were observed in the improved method. In the conclusion, the accuracy of ultrasound fat measurement improved with the improvement made on ultrasonic velocity measurement used in adapted B-mode imaging. 2015-01 Thesis https://ir.uitm.edu.my/id/eprint/14074/ https://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf text en public mphil masters Universiti Teknologi MARA Faculty of Electrical Engineering Buniyamin, Norlida (Assoc. Prof. Ir. Dr.)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Buniyamin, Norlida (Assoc. Prof. Ir. Dr.)
topic Image processing
spellingShingle Image processing
Abdul Halim, Muhamad Hazwan
Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
description Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relatively low-cost advantages. The improvement in ultrasound method for fat measurement is not only on the advancement of the ultrasound equipment but also the accuracy of data analysis. Two current issues that have arisen are the influence of protective layer on the accuracy of ultrasonic velocity measurement using A-mode analysis and the B-mode image positioning accuracy due to the application of the predetermined ultrasonic velocity in B-mode imaging. This research implemented new approach in performing the measurement of ultrasonic velocity and ultrasound B-mode analysis. To increase the accuracy of ultrasonic velocity measurement, the thickness of the protective layer was first determined used in ultrasonic velocity measurement. To increase the positioning accuracy of B-mode image, the actual determined velocity was used rather than the predetermined velocity. The improvements made were successful in increasing the accuracy of the ultrasonic velocity measurement and the positioning of the B - mode image. Subsequently, this method was then used to measure intramuscular fat content in chicken fillet. Better correlations between the ultrasound properties (velocity, image histogram mean and percentages of fat pixel) and percentage of fat content measured by Soxhlet Method were observed in the improved method. In the conclusion, the accuracy of ultrasound fat measurement improved with the improvement made on ultrasonic velocity measurement used in adapted B-mode imaging.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Abdul Halim, Muhamad Hazwan
author_facet Abdul Halim, Muhamad Hazwan
author_sort Abdul Halim, Muhamad Hazwan
title Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_short Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_full Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_fullStr Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_full_unstemmed Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_sort improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / muhamad hazwan abdul halim
granting_institution Universiti Teknologi MARA
granting_department Faculty of Electrical Engineering
publishDate 2015
url https://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf
_version_ 1783733207689068544