The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi

The purposed of this research is to focus on the interface shear strength between geotextiles and soil with different percentage of sodium bentonite. Firstly, the physical properties of the soil sample must be identified in orderr to determine the soil classification. The laboratory test includes at...

Full description

Saved in:
Bibliographic Details
Main Author: Che Azmi, Nor Azizah
Format: Thesis
Language:English
Published: 2013
Online Access:https://ir.uitm.edu.my/id/eprint/16370/1/TM_NOR%20AZIZAH%20CHE%20AZMI%20EC%2013_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.16370
record_format uketd_dc
spelling my-uitm-ir.163702022-04-13T01:00:40Z The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi 2013-06 Che Azmi, Nor Azizah The purposed of this research is to focus on the interface shear strength between geotextiles and soil with different percentage of sodium bentonite. Firstly, the physical properties of the soil sample must be identified in orderr to determine the soil classification. The laboratory test includes atterberg limit test, shrinkage limit test, specific gravity test, pH test, sieve analysis test and hydrometer test. The soil samples which are natural soil sample, soil added with 0% of sodium bentonite, soil added with 2.5% of sodium bentonite, soil added with 5.0% of sodium bentonite, soil added with 7.5% of sodium bentonite and soil added with 10% of sodium bentonite. Based on the result, the percentage of sodium bentonite did not give good relationship to the soil samples such liquid limit test, plastic limit test, plasticity index and specific gravity as the value that obtained quite similar and did not increased when increasing percentage of sodium bentonite. After the soil is classified, the next test was compaction test. The puipose of the compaction test is to get the value of optimum moisture content that need to be applied during direct shear box test. However, the value for compaction and direct shear test also did not give good result as the value for optimum moisture content, cohesion and friction angle also quite similar to each other thus, it can be clearly said that the percentage of sodium bentonite did not give effect to the soil samples and not suitable to be use in this type of soil. 2013-06 Thesis https://ir.uitm.edu.my/id/eprint/16370/ https://ir.uitm.edu.my/id/eprint/16370/1/TM_NOR%20AZIZAH%20CHE%20AZMI%20EC%2013_5.pdf text en public mphil masters Universiti Teknologi MARA Faculty of Civil Engineering Mukri, Mazidah (Dr)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Mukri, Mazidah (Dr)
description The purposed of this research is to focus on the interface shear strength between geotextiles and soil with different percentage of sodium bentonite. Firstly, the physical properties of the soil sample must be identified in orderr to determine the soil classification. The laboratory test includes atterberg limit test, shrinkage limit test, specific gravity test, pH test, sieve analysis test and hydrometer test. The soil samples which are natural soil sample, soil added with 0% of sodium bentonite, soil added with 2.5% of sodium bentonite, soil added with 5.0% of sodium bentonite, soil added with 7.5% of sodium bentonite and soil added with 10% of sodium bentonite. Based on the result, the percentage of sodium bentonite did not give good relationship to the soil samples such liquid limit test, plastic limit test, plasticity index and specific gravity as the value that obtained quite similar and did not increased when increasing percentage of sodium bentonite. After the soil is classified, the next test was compaction test. The puipose of the compaction test is to get the value of optimum moisture content that need to be applied during direct shear box test. However, the value for compaction and direct shear test also did not give good result as the value for optimum moisture content, cohesion and friction angle also quite similar to each other thus, it can be clearly said that the percentage of sodium bentonite did not give effect to the soil samples and not suitable to be use in this type of soil.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Che Azmi, Nor Azizah
spellingShingle Che Azmi, Nor Azizah
The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
author_facet Che Azmi, Nor Azizah
author_sort Che Azmi, Nor Azizah
title The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
title_short The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
title_full The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
title_fullStr The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
title_full_unstemmed The study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / Nor Azizah Che Azmi
title_sort study of interface shear strength between geotextile and soil liner containing with different percentage of sodium bentonite / nor azizah che azmi
granting_institution Universiti Teknologi MARA
granting_department Faculty of Civil Engineering
publishDate 2013
url https://ir.uitm.edu.my/id/eprint/16370/1/TM_NOR%20AZIZAH%20CHE%20AZMI%20EC%2013_5.pdf
_version_ 1783733514179444736