The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli

In this study, the effects of kilovoltages (kVp) and tube currents (mAs) on Computed Tomography Angiography (CTA) head phantom images were investigated quantitavely using ImageJ software due to insufficient understanding on the relationship between these parameters on CT image quality and doses. The...

Full description

Saved in:
Bibliographic Details
Main Author: Dzulkafli, Sity Noor Ayseah
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/17806/1/TM_SITY%20NOOR%20AYSEAH%20DZULKAFLI%20HS%2015_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.17806
record_format uketd_dc
spelling my-uitm-ir.178062018-10-18T06:25:33Z The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli 2015 Dzulkafli, Sity Noor Ayseah Neural Networks (Computer). Artificial intelligence In this study, the effects of kilovoltages (kVp) and tube currents (mAs) on Computed Tomography Angiography (CTA) head phantom images were investigated quantitavely using ImageJ software due to insufficient understanding on the relationship between these parameters on CT image quality and doses. The objective of this study is to investigate the effect of kilovoltages (kVp) and tube current (mAs) parameters quantitatively on several parameters namely; 1) image quality 2) dose 3) Signal to Noise Ratio (SNR) and 4) contrast. The parameters have been varied during the CT scan examination and the results have been compared for each kilovoltages (kVp) and tube currents (mAs) using ImageJ software. In brief, varying the kilovoltages (kVp) and tube current (mAs) will enhance the image quality but will also increase the dose exposure to the patient. Higher doses are one of the problems that researchers have to overcome in patient diagnosis in order to have an optimum image quality with lower doses. The results include the relationship between the parameters and image quality and also dose in selected type or arteries; Anterior Cerebral Artery (ACA), Middle Cerebral Artery (MCA) and Internal Carotid Artery (ICA) in CTA. Decreasing kVp do increase image contrasts while increasing mAs play roles in reducing the noise of the image. Finally, the suggested parameters used for brain examination is 100 kVp with 360 mAs in line with the recommended CTDIvol dose value as in Computed Tomography European Guidelines. 2015 Thesis https://ir.uitm.edu.my/id/eprint/17806/ https://ir.uitm.edu.my/id/eprint/17806/1/TM_SITY%20NOOR%20AYSEAH%20DZULKAFLI%20HS%2015_5.pdf text en public mphil masters Universiti Teknologi MARA Faculty of Health Sciences
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Neural Networks (Computer)
Artificial intelligence
spellingShingle Neural Networks (Computer)
Artificial intelligence
Dzulkafli, Sity Noor Ayseah
The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
description In this study, the effects of kilovoltages (kVp) and tube currents (mAs) on Computed Tomography Angiography (CTA) head phantom images were investigated quantitavely using ImageJ software due to insufficient understanding on the relationship between these parameters on CT image quality and doses. The objective of this study is to investigate the effect of kilovoltages (kVp) and tube current (mAs) parameters quantitatively on several parameters namely; 1) image quality 2) dose 3) Signal to Noise Ratio (SNR) and 4) contrast. The parameters have been varied during the CT scan examination and the results have been compared for each kilovoltages (kVp) and tube currents (mAs) using ImageJ software. In brief, varying the kilovoltages (kVp) and tube current (mAs) will enhance the image quality but will also increase the dose exposure to the patient. Higher doses are one of the problems that researchers have to overcome in patient diagnosis in order to have an optimum image quality with lower doses. The results include the relationship between the parameters and image quality and also dose in selected type or arteries; Anterior Cerebral Artery (ACA), Middle Cerebral Artery (MCA) and Internal Carotid Artery (ICA) in CTA. Decreasing kVp do increase image contrasts while increasing mAs play roles in reducing the noise of the image. Finally, the suggested parameters used for brain examination is 100 kVp with 360 mAs in line with the recommended CTDIvol dose value as in Computed Tomography European Guidelines.
format Thesis
qualification_name Master of Philosophy (M.Phil.)
qualification_level Master's degree
author Dzulkafli, Sity Noor Ayseah
author_facet Dzulkafli, Sity Noor Ayseah
author_sort Dzulkafli, Sity Noor Ayseah
title The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
title_short The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
title_full The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
title_fullStr The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
title_full_unstemmed The effect of varying kilovoltage (kVp) and tube current (mAs) on the image quality and dose of CTA head phantom / Sity Noor Ayseah Dzulkafli
title_sort effect of varying kilovoltage (kvp) and tube current (mas) on the image quality and dose of cta head phantom / sity noor ayseah dzulkafli
granting_institution Universiti Teknologi MARA
granting_department Faculty of Health Sciences
publishDate 2015
url https://ir.uitm.edu.my/id/eprint/17806/1/TM_SITY%20NOOR%20AYSEAH%20DZULKAFLI%20HS%2015_5.pdf
_version_ 1783733603591520256