Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid

This thesis proposes a new power tracing technique using computational intelligence approach for non discriminatory losses charge allocation and voltage stability improvement. Contrary to conventional techniques which mainly rely on matrix operation, the proposed algorithm implements optimization te...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Hamid, Zulkiffli
Format: Thesis
Language:English
Published: 2013
Online Access:https://ir.uitm.edu.my/id/eprint/18335/2/TP_ZULKIFLI%20ABDUL%20HAMID%20EE%2013_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.18335
record_format uketd_dc
spelling my-uitm-ir.183352023-03-08T02:13:14Z Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid 2013-08 Abdul Hamid, Zulkiffli This thesis proposes a new power tracing technique using computational intelligence approach for non discriminatory losses charge allocation and voltage stability improvement. Contrary to conventional techniques which mainly rely on matrix operation, the proposed algorithm implements optimization technique as an alternative for performing the tracing process. At first, in producing a good optimization algorithm, a hybridization technique was proposed for adopting the finest features of two different algorithms; namely the Genetic Algorithm (GA) and continuous domain Ant Colony Optimization (ACOr). The hybrid algorithm is termed as the Blended Crossover Continuous Ant Colony Optimization (BX-CACO). It was found that performing power tracing via BX-CACO produced reliable tracing results as it is free from assumption like proportional sharing principle (PSP). Without treating the power system to be lossless, the tracing results are based on actual system condition; which means that they are consistent. Despite BX-CACO required computation time during optimization process, it is still within tolerable range. In addition, the proposed technique was able to promote fair losses charge allocation by involving imaginary consumers other than generation companies (GENCOs) and distribution companies (DISCOs); where, not all conventional tracing techniques include such consideration in their pricing scheme. Subsequently, the developed tracing algorithm was modified in the context of stability index tracing. At this stage, the limited application of power tracing in the field of power system economics was enhanced for the purpose of voltage stability improvement. By utilizing the Fast Voltage Stability Index (FVSI) as the index to be traced, the proposed stability index tracing is called FFSZ-Tracing (FVSI-T); which consists of two schemes namely /•’KSY-Gcneration Tracing (FVSI-GT) and F VS I-Load Tracing (FVSFLT). From both schemes of FVSI-T, a ranking list indicating the priority of buses to be performed any countermeasures against voltage instability was derived. Contrary to conventional techniques such as sensitivity analysis and stability index approach, the derived ranking list consists of two types of locations ranked based on their priority; which are bus and line. In addition, the ranking list derived from BX-CACO-based-/*TS/-T is available at any system conditions and includes all possible sources and sinks that also participate in the system. This highlights its merit over conventional ranking techniques. After experiment and comparative studies, it was justified that the derived ranking list gave reliable signal for satisfactory and consistent voltage stability improvement in the problem of generation power dispatch, placement of compensating devices, and load shedding. Regardless of the change in system condition, the derived ranking list from FVSI-T resulted in steady trend of voltage magnitude and consistent losses reduction as compared to convetional methods. Eventually, in providing an effective load shedding scheme with reliable amount of load power to be shed, an intuitive Fuzzy Inference System (FIS) was designed using FVSI as the criterion when designing its membership functions and rules. Through experiment, the proposed method resulted in the most consistent voltage stability improvement over other methods as both FIS and the derived ranking list are based on FVSI. 2013-08 Thesis https://ir.uitm.edu.my/id/eprint/18335/ https://ir.uitm.edu.my/id/eprint/18335/2/TP_ZULKIFLI%20ABDUL%20HAMID%20EE%2013_5.pdf text en public phd doctoral Universiti Teknologi MARA Faculty of Electrical Engineering
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
description This thesis proposes a new power tracing technique using computational intelligence approach for non discriminatory losses charge allocation and voltage stability improvement. Contrary to conventional techniques which mainly rely on matrix operation, the proposed algorithm implements optimization technique as an alternative for performing the tracing process. At first, in producing a good optimization algorithm, a hybridization technique was proposed for adopting the finest features of two different algorithms; namely the Genetic Algorithm (GA) and continuous domain Ant Colony Optimization (ACOr). The hybrid algorithm is termed as the Blended Crossover Continuous Ant Colony Optimization (BX-CACO). It was found that performing power tracing via BX-CACO produced reliable tracing results as it is free from assumption like proportional sharing principle (PSP). Without treating the power system to be lossless, the tracing results are based on actual system condition; which means that they are consistent. Despite BX-CACO required computation time during optimization process, it is still within tolerable range. In addition, the proposed technique was able to promote fair losses charge allocation by involving imaginary consumers other than generation companies (GENCOs) and distribution companies (DISCOs); where, not all conventional tracing techniques include such consideration in their pricing scheme. Subsequently, the developed tracing algorithm was modified in the context of stability index tracing. At this stage, the limited application of power tracing in the field of power system economics was enhanced for the purpose of voltage stability improvement. By utilizing the Fast Voltage Stability Index (FVSI) as the index to be traced, the proposed stability index tracing is called FFSZ-Tracing (FVSI-T); which consists of two schemes namely /•’KSY-Gcneration Tracing (FVSI-GT) and F VS I-Load Tracing (FVSFLT). From both schemes of FVSI-T, a ranking list indicating the priority of buses to be performed any countermeasures against voltage instability was derived. Contrary to conventional techniques such as sensitivity analysis and stability index approach, the derived ranking list consists of two types of locations ranked based on their priority; which are bus and line. In addition, the ranking list derived from BX-CACO-based-/*TS/-T is available at any system conditions and includes all possible sources and sinks that also participate in the system. This highlights its merit over conventional ranking techniques. After experiment and comparative studies, it was justified that the derived ranking list gave reliable signal for satisfactory and consistent voltage stability improvement in the problem of generation power dispatch, placement of compensating devices, and load shedding. Regardless of the change in system condition, the derived ranking list from FVSI-T resulted in steady trend of voltage magnitude and consistent losses reduction as compared to convetional methods. Eventually, in providing an effective load shedding scheme with reliable amount of load power to be shed, an intuitive Fuzzy Inference System (FIS) was designed using FVSI as the criterion when designing its membership functions and rules. Through experiment, the proposed method resulted in the most consistent voltage stability improvement over other methods as both FIS and the derived ranking list are based on FVSI.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Abdul Hamid, Zulkiffli
spellingShingle Abdul Hamid, Zulkiffli
Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
author_facet Abdul Hamid, Zulkiffli
author_sort Abdul Hamid, Zulkiffli
title Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
title_short Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
title_full Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
title_fullStr Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
title_full_unstemmed Computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / Zulkiffli Abdul Hamid
title_sort computational intelligence based power tracing for non discriminatory losses charge allocation and voltage stability improvement / zulkiffli abdul hamid
granting_institution Universiti Teknologi MARA
granting_department Faculty of Electrical Engineering
publishDate 2013
url https://ir.uitm.edu.my/id/eprint/18335/2/TP_ZULKIFLI%20ABDUL%20HAMID%20EE%2013_5.pdf
_version_ 1783733664199213056