Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman

Purpose: Cosmetic contact lens wearer had increased over the years. The increasing numbers of unlicensed practitioner promoting and selling the cosmetic contact lenses had become a concern. This was because the contact lens was not fitted properly to the patient’s eye. The materials of the contact l...

Full description

Saved in:
Bibliographic Details
Main Author: Abd Rahman, Nur Aisyah
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/22381/1/TD_NUR%20AISYAH%20ABD%20RAHMAN%20HS%20B%2016_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.22381
record_format uketd_dc
spelling my-uitm-ir.223812018-12-14T02:49:19Z Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman 2016 Abd Rahman, Nur Aisyah Optometry. Opticians. Eyeglasses Eyeglasses. Lenses Purpose: Cosmetic contact lens wearer had increased over the years. The increasing numbers of unlicensed practitioner promoting and selling the cosmetic contact lenses had become a concern. This was because the contact lens was not fitted properly to the patient’s eye. The materials of the contact lenses were sometimes not known and therefore were dangerous. The aim of this research was to find out if there were any differences of contrast sensitivity between the two tested groups. The two groups were those who bought the cosmetic contact lenses from unlicensed practitioner and those who bought cosmetic contact lenses from licensed practitioners. Results: The study method used in this study was purposive sampling. The tools and instruments used were the slit lamp bio-microscopy, the CSV 1000E chart and the Snellen chart. To compare the means between the two groups, Mann-Whitney U Test was used because the data was not normal. By using the CSV 1000E chart, there were no significant differences in contrast sensitivity function in both tested groups. For each spatial frequency tested, the p values for 3 cpd was 0.918, 6 cpd = 0.382, 12 cpd = 0.318 and for 18 cpd = 0.187. Conclusion: This study has failed to show that cosmetic contact lens bought from unlicensed practitioner caused contrast sensitivity reduction. Future study should be done with larger sample size, various cosmetic contact lens brands, colors and designs, measuring the contact lens thickness, noting the water contents of the contact lenses and taking account of the corneal edema. The implication of this study was to find out if there were any effects in contrast sensitivity if the contact lens were bought from different sources. 2016 Thesis https://ir.uitm.edu.my/id/eprint/22381/ https://ir.uitm.edu.my/id/eprint/22381/1/TD_NUR%20AISYAH%20ABD%20RAHMAN%20HS%20B%2016_5.pdf text en public degree Universiti Teknologi MARA, Selangor, Puncak Alam Campus Faculty of Health Science
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Optometry
Opticians
Eyeglasses
Optometry
Opticians
Eyeglasses
spellingShingle Optometry
Opticians
Eyeglasses
Optometry
Opticians
Eyeglasses
Abd Rahman, Nur Aisyah
Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
description Purpose: Cosmetic contact lens wearer had increased over the years. The increasing numbers of unlicensed practitioner promoting and selling the cosmetic contact lenses had become a concern. This was because the contact lens was not fitted properly to the patient’s eye. The materials of the contact lenses were sometimes not known and therefore were dangerous. The aim of this research was to find out if there were any differences of contrast sensitivity between the two tested groups. The two groups were those who bought the cosmetic contact lenses from unlicensed practitioner and those who bought cosmetic contact lenses from licensed practitioners. Results: The study method used in this study was purposive sampling. The tools and instruments used were the slit lamp bio-microscopy, the CSV 1000E chart and the Snellen chart. To compare the means between the two groups, Mann-Whitney U Test was used because the data was not normal. By using the CSV 1000E chart, there were no significant differences in contrast sensitivity function in both tested groups. For each spatial frequency tested, the p values for 3 cpd was 0.918, 6 cpd = 0.382, 12 cpd = 0.318 and for 18 cpd = 0.187. Conclusion: This study has failed to show that cosmetic contact lens bought from unlicensed practitioner caused contrast sensitivity reduction. Future study should be done with larger sample size, various cosmetic contact lens brands, colors and designs, measuring the contact lens thickness, noting the water contents of the contact lenses and taking account of the corneal edema. The implication of this study was to find out if there were any effects in contrast sensitivity if the contact lens were bought from different sources.
format Thesis
qualification_level Bachelor degree
author Abd Rahman, Nur Aisyah
author_facet Abd Rahman, Nur Aisyah
author_sort Abd Rahman, Nur Aisyah
title Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
title_short Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
title_full Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
title_fullStr Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
title_full_unstemmed Contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / Nur Aisyah Abd Rahman
title_sort contrast sensitivity function in cosmetic contact lens wearers from licensed and unlicensed practitioner / nur aisyah abd rahman
granting_institution Universiti Teknologi MARA, Selangor, Puncak Alam Campus
granting_department Faculty of Health Science
publishDate 2016
url https://ir.uitm.edu.my/id/eprint/22381/1/TD_NUR%20AISYAH%20ABD%20RAHMAN%20HS%20B%2016_5.pdf
_version_ 1783733810088640512