Super High Rise building has emerged in Malaysia due to its rapid requirement of office space by commercial corporation. Typically, all high rise buildings require state of the art air-conditioning system to maintain a comfort and conductive working environment in a high temperature and humidity con...

Full description

Saved in:
Bibliographic Details
Main Author: Bakri, Rudy Irawan
Format: Thesis
Language:English
Published: 2003
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/24607/1/TD_RUDY%20IRAWAN%20BAKRI%20AP%2003_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.24607
record_format uketd_dc
spelling my-uitm-ir.246072019-07-25T08:32:37Z Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri 2003 Bakri, Rudy Irawan Contractors Management of the construction site. Superintendence of building construction Production management. Operations management Super High Rise building has emerged in Malaysia due to its rapid requirement of office space by commercial corporation. Typically, all high rise buildings require state of the art air-conditioning system to maintain a comfort and conductive working environment in a high temperature and humidity condition in Malaysia. Most of the building owners have opted to subscribe chilled water provided by District Cooling developer. Rather than producing themselves. This has also lead to the development of large scale privately owned District Cooling System, Ice Storage and Cogeneration Plant in Malaysia. District Cooling System is defined as production and supplying of chilled water for air-conditioning form central location to various buildings within the development using the underground chilled water preinsulated piping network. Large scale District Cooling with cogeneration has been built to cater growing needs of chilled water for air-conditioning. Cogeneration is used to provide electricity for the DCS and simultaneously producing chilled water using steam boiler and absorption chiller. In addition, Ice Thermal Storage is a demand management technology whereby it has an ability to shift air-conditioning load from daytime peak hours to night time off-peak hours using a special off-peak electricity tariff offered by Power Company. 2003 Thesis https://ir.uitm.edu.my/id/eprint/24607/ https://ir.uitm.edu.my/id/eprint/24607/1/TD_RUDY%20IRAWAN%20BAKRI%20AP%2003_5.pdf text en public degree Universiti Teknologi MARA Faculty of Architecture, Planning and Surveying
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Contractors
Contractors
Contractors
spellingShingle Contractors
Contractors
Contractors
Bakri, Rudy Irawan
Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
description Super High Rise building has emerged in Malaysia due to its rapid requirement of office space by commercial corporation. Typically, all high rise buildings require state of the art air-conditioning system to maintain a comfort and conductive working environment in a high temperature and humidity condition in Malaysia. Most of the building owners have opted to subscribe chilled water provided by District Cooling developer. Rather than producing themselves. This has also lead to the development of large scale privately owned District Cooling System, Ice Storage and Cogeneration Plant in Malaysia. District Cooling System is defined as production and supplying of chilled water for air-conditioning form central location to various buildings within the development using the underground chilled water preinsulated piping network. Large scale District Cooling with cogeneration has been built to cater growing needs of chilled water for air-conditioning. Cogeneration is used to provide electricity for the DCS and simultaneously producing chilled water using steam boiler and absorption chiller. In addition, Ice Thermal Storage is a demand management technology whereby it has an ability to shift air-conditioning load from daytime peak hours to night time off-peak hours using a special off-peak electricity tariff offered by Power Company.
format Thesis
qualification_level Bachelor degree
author Bakri, Rudy Irawan
author_facet Bakri, Rudy Irawan
author_sort Bakri, Rudy Irawan
title Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
title_short Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
title_full Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
title_fullStr Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
title_full_unstemmed Effectiveness of operational on ice thermal energy storage system / Rudy Irawan Bakri
title_sort effectiveness of operational on ice thermal energy storage system / rudy irawan bakri
granting_institution Universiti Teknologi MARA
granting_department Faculty of Architecture, Planning and Surveying
publishDate 2003
url https://ir.uitm.edu.my/id/eprint/24607/1/TD_RUDY%20IRAWAN%20BAKRI%20AP%2003_5.pdf
_version_ 1783733851581841408