Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor

Polymorphonuclear neutrophils (PMNs) are white blood cells that play an important role as the first line of immune defence against pathogens. Neutrophils activation will trigger production of oxidative burst which is mediated by NADPH oxidase. The product of oxidative burst is a part of the powerful...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Noor, Nurain Zulaika
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/28090/1/TD_NURAIN%20ZULAIKHA%20MOHD%20NOOR%20HS%2015_5.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.28090
record_format uketd_dc
spelling my-uitm-ir.280902020-02-03T04:11:11Z Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor 2015 Mohd Noor, Nurain Zulaika Clinical pathology. Laboratory technique Polymorphonuclear neutrophils (PMNs) are white blood cells that play an important role as the first line of immune defence against pathogens. Neutrophils activation will trigger production of oxidative burst which is mediated by NADPH oxidase. The product of oxidative burst is a part of the powerful bacteria killing system in PMNs. Neutrophils function is evaluated based on its ability to produce oxidative burst. The conventional nitroblue tetrazolium (NBT) assay is the gold standard method to evaluate neutrophils function. The NBT test is however laborious, complicated and skill-dependent. An alternative method called direct NBT assay was recently introduced. Thus, in the present study, the performance between conventional and direct NBT assays were compared. A total of 20 heparinized venous blood samples from normal individuals and one sample from chronic myeloid leukaemia (CML) patient were evaluated for neutrophil function by using both methods. There was a good correlation between conventional and direct NBT assays for percentage ofNBT positive cell with PMA stimulated cells (rs=0.97, P<O.OI) and unstimulated cells (rs=0.93, P<O.OI). Hence, the results from direct NBT assay is as comparable as that of conventional NBT assay. The direct NBT assay is quicker and simpler than the conventional NBT assay because whole blood is used thus it eliminates the preparation ofPMNs cell. In addition, sample volume of as small as 0.1 ml blood can be used which makes the direct NBT assay ideal for evaluation of neutrophil function in children and neonates. Therefore, the direct NBT assay may be a better choice or an alternative approach to evaluate neutrophil function as it is quicker, simpler, easier and less skill needed. 2015 Thesis https://ir.uitm.edu.my/id/eprint/28090/ https://ir.uitm.edu.my/id/eprint/28090/1/TD_NURAIN%20ZULAIKHA%20MOHD%20NOOR%20HS%2015_5.pdf text en public degree Universiti Teknologi MARA Faculty of Health Sciences
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
topic Clinical pathology
Laboratory technique
spellingShingle Clinical pathology
Laboratory technique
Mohd Noor, Nurain Zulaika
Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
description Polymorphonuclear neutrophils (PMNs) are white blood cells that play an important role as the first line of immune defence against pathogens. Neutrophils activation will trigger production of oxidative burst which is mediated by NADPH oxidase. The product of oxidative burst is a part of the powerful bacteria killing system in PMNs. Neutrophils function is evaluated based on its ability to produce oxidative burst. The conventional nitroblue tetrazolium (NBT) assay is the gold standard method to evaluate neutrophils function. The NBT test is however laborious, complicated and skill-dependent. An alternative method called direct NBT assay was recently introduced. Thus, in the present study, the performance between conventional and direct NBT assays were compared. A total of 20 heparinized venous blood samples from normal individuals and one sample from chronic myeloid leukaemia (CML) patient were evaluated for neutrophil function by using both methods. There was a good correlation between conventional and direct NBT assays for percentage ofNBT positive cell with PMA stimulated cells (rs=0.97, P<O.OI) and unstimulated cells (rs=0.93, P<O.OI). Hence, the results from direct NBT assay is as comparable as that of conventional NBT assay. The direct NBT assay is quicker and simpler than the conventional NBT assay because whole blood is used thus it eliminates the preparation ofPMNs cell. In addition, sample volume of as small as 0.1 ml blood can be used which makes the direct NBT assay ideal for evaluation of neutrophil function in children and neonates. Therefore, the direct NBT assay may be a better choice or an alternative approach to evaluate neutrophil function as it is quicker, simpler, easier and less skill needed.
format Thesis
qualification_level Bachelor degree
author Mohd Noor, Nurain Zulaika
author_facet Mohd Noor, Nurain Zulaika
author_sort Mohd Noor, Nurain Zulaika
title Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
title_short Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
title_full Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
title_fullStr Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
title_full_unstemmed Neutrophil function test: comparison between Conventional Nitroblue Tetrazolium (NBT) and direct NBT assays / Nurain Zulaika Mohd Noor
title_sort neutrophil function test: comparison between conventional nitroblue tetrazolium (nbt) and direct nbt assays / nurain zulaika mohd noor
granting_institution Universiti Teknologi MARA
granting_department Faculty of Health Sciences
publishDate 2015
url https://ir.uitm.edu.my/id/eprint/28090/1/TD_NURAIN%20ZULAIKHA%20MOHD%20NOOR%20HS%2015_5.pdf
_version_ 1783734050750464000