Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar

This project looks into the water cooling system of a Hydro Power Plant in Stesen Janaelektrik Sultan Mahmud, Kenyir. The plant is currently using an open circuit water cooling system. The water for the cooling system is taken from the ne!3rest river. With the existing system, the water produces a l...

Full description

Saved in:
Bibliographic Details
Main Author: Kushiar, Khairul Faizal
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/31171/1/31171.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.31171
record_format uketd_dc
spelling my-uitm-ir.311712024-04-22T08:46:22Z Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar 2009 Kushiar, Khairul Faizal Power plants This project looks into the water cooling system of a Hydro Power Plant in Stesen Janaelektrik Sultan Mahmud, Kenyir. The plant is currently using an open circuit water cooling system. The water for the cooling system is taken from the ne!3rest river. With the existing system, the water produces a lot of sludge that has blocked the delivery tube line in the cooler. This problem has slightly reduced the heat transfer from the generator to the cooling system and the efficiency of the cooler. The main objective of this project is to address this issue. The project has been carried out in two parts. The first part of the project is to study, assess, and properly document the current water cooling system and the major problems reported. In the second part of the project, different water cooling systems are discussed from which the most practical system has been selected and presented as solution for the current problem faced in the hydro power plant. Some of the design criteria of the proposed cooling system are to reduce maintenance cost and work for the cooler. The outcome of this project is a detailed proposal of a new cooling system that will eliminate the present problem face by the Hydro Power Plant in Stesen Janaelektrik Sultan Mahmud, Kenyir. 2009 Thesis https://ir.uitm.edu.my/id/eprint/31171/ https://ir.uitm.edu.my/id/eprint/31171/1/31171.pdf text en public degree Universiti Teknologi MARA Shah Alam Faculty of Mechanical Engineering Kasolang @ Kasalung, Salmiah
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Kasolang @ Kasalung, Salmiah
topic Power plants
spellingShingle Power plants
Kushiar, Khairul Faizal
Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
description This project looks into the water cooling system of a Hydro Power Plant in Stesen Janaelektrik Sultan Mahmud, Kenyir. The plant is currently using an open circuit water cooling system. The water for the cooling system is taken from the ne!3rest river. With the existing system, the water produces a lot of sludge that has blocked the delivery tube line in the cooler. This problem has slightly reduced the heat transfer from the generator to the cooling system and the efficiency of the cooler. The main objective of this project is to address this issue. The project has been carried out in two parts. The first part of the project is to study, assess, and properly document the current water cooling system and the major problems reported. In the second part of the project, different water cooling systems are discussed from which the most practical system has been selected and presented as solution for the current problem faced in the hydro power plant. Some of the design criteria of the proposed cooling system are to reduce maintenance cost and work for the cooler. The outcome of this project is a detailed proposal of a new cooling system that will eliminate the present problem face by the Hydro Power Plant in Stesen Janaelektrik Sultan Mahmud, Kenyir.
format Thesis
qualification_level Bachelor degree
author Kushiar, Khairul Faizal
author_facet Kushiar, Khairul Faizal
author_sort Kushiar, Khairul Faizal
title Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
title_short Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
title_full Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
title_fullStr Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
title_full_unstemmed Cooling water system of hydro power plant: A case study / Khairul Faizal Kushiar
title_sort cooling water system of hydro power plant: a case study / khairul faizal kushiar
granting_institution Universiti Teknologi MARA Shah Alam
granting_department Faculty of Mechanical Engineering
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/31171/1/31171.pdf