Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.

The lighting systems consume 12% amount of energy supplied in a commercial building in Malaysia16. In UiTM Shah Alam, most of the fluorescent lamps are always turned on 24 hours per day especially at the corridor site which contribute to significant energy wastage. Some areas also use excessive numb...

全面介绍

Saved in:
书目详细资料
主要作者: Mohd Aliambran, Mohd Fared
格式: Thesis
语言:English
出版: 2009
主题:
在线阅读:https://ir.uitm.edu.my/id/eprint/31572/1/31572.pdf
标签: 添加标签
没有标签, 成为第一个标记此记录!
id my-uitm-ir.31572
record_format uketd_dc
spelling my-uitm-ir.315722024-04-18T08:12:26Z Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran. 2009 Mohd Aliambran, Mohd Fared Energy audits The lighting systems consume 12% amount of energy supplied in a commercial building in Malaysia16. In UiTM Shah Alam, most of the fluorescent lamps are always turned on 24 hours per day especially at the corridor site which contribute to significant energy wastage. Some areas also use excessive number of fluorescent lamps which the space becomes too bright and this will also contribute energy wastage. Various electrical energy saving measures are reviewed and proposed to be implemented to reduce energy wastage. There are two proposed methods which may reduce the electrical energy wastage from the lighting system. First is by calculating the optimum number of fluorescent lamps which fulfil the minimum requirement of lighting in the area or building. Second is by using a system that can control the lighting system while maintaining a comfort and safe environment in the building. This paper presents a study on the lighting system which focuses on fluorescent lamps at Science and Technology Mara Towers in UiTM Shah Alam especially along the lecturer's room corridor where the most of power wastage occurs. ECS time-based control system is the proposed system that can control the lighting system in the focused area which is expected to contribute a significant reduction in electrical energy consumption in the building is also presented. 2009 Thesis https://ir.uitm.edu.my/id/eprint/31572/ https://ir.uitm.edu.my/id/eprint/31572/1/31572.pdf text en public degree Universiti Teknologi MARA Shah Alam Faculty of Mechanical Engineering, Universiti Teknologi MARA Shah Alam Zailani, Ramlan (Prof. Madya Dr)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Zailani, Ramlan (Prof. Madya Dr)
topic Energy audits
spellingShingle Energy audits
Mohd Aliambran, Mohd Fared
Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
description The lighting systems consume 12% amount of energy supplied in a commercial building in Malaysia16. In UiTM Shah Alam, most of the fluorescent lamps are always turned on 24 hours per day especially at the corridor site which contribute to significant energy wastage. Some areas also use excessive number of fluorescent lamps which the space becomes too bright and this will also contribute energy wastage. Various electrical energy saving measures are reviewed and proposed to be implemented to reduce energy wastage. There are two proposed methods which may reduce the electrical energy wastage from the lighting system. First is by calculating the optimum number of fluorescent lamps which fulfil the minimum requirement of lighting in the area or building. Second is by using a system that can control the lighting system while maintaining a comfort and safe environment in the building. This paper presents a study on the lighting system which focuses on fluorescent lamps at Science and Technology Mara Towers in UiTM Shah Alam especially along the lecturer's room corridor where the most of power wastage occurs. ECS time-based control system is the proposed system that can control the lighting system in the focused area which is expected to contribute a significant reduction in electrical energy consumption in the building is also presented.
format Thesis
qualification_level Bachelor degree
author Mohd Aliambran, Mohd Fared
author_facet Mohd Aliambran, Mohd Fared
author_sort Mohd Aliambran, Mohd Fared
title Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
title_short Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
title_full Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
title_fullStr Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
title_full_unstemmed Energy auditing and energy saving measure of the lighting systems in the UiTM engineering tower blocks / Mohd Fared Mohd Ali Ambran.
title_sort energy auditing and energy saving measure of the lighting systems in the uitm engineering tower blocks / mohd fared mohd ali ambran.
granting_institution Universiti Teknologi MARA Shah Alam
granting_department Faculty of Mechanical Engineering, Universiti Teknologi MARA Shah Alam
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/31572/1/31572.pdf
_version_ 1804889626493583360