Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin

Resurfacing Hip Arthroplasty (RHA) is a hip replacement method that is widely known nowadays. This method usually applied to the hip disease patients who are in the late stage condition. RHA method is most recommended to the young and active patients since high successful rate was recorded to these...

Full description

Saved in:
Bibliographic Details
Main Author: Nor Izmin, Nor Aiman
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/59594/1/59594.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.59594
record_format uketd_dc
spelling my-uitm-ir.595942022-05-13T08:39:38Z Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin 2020-03 Nor Izmin, Nor Aiman Medical technology Resurfacing Hip Arthroplasty (RHA) is a hip replacement method that is widely known nowadays. This method usually applied to the hip disease patients who are in the late stage condition. RHA method is most recommended to the young and active patients since high successful rate was recorded to these group of candidates. However, the complication of femoral bone fracture often happens in this hip replacement method which associated with the implant positioning. The objective of this study is to quantify the effects of RHA implant placement towards the bone adaptation for prediction of femoral bone fracture risk by using finite element analysis. Finite element analysis was conducted to predict the damage formation of the bone model based on the computed tomography (CT) image of a patient. A 3D inhomogeneous bone model was developed from computed tomography (CT) image of a 47 years old patient with a hip osteoarthritis disease by using a biomechanical modelling software, Mechanical Finder. The material properties used for the RHA implant model was based on the properties of cobalt-chromium (CoCr). Straight implant placement was firstly developed by referring to the natural shaft-neck axis of the femoral bone, before generating several implant placement in varus and valgus. 13 implanted femur models with implant angle +3°, +6°, +9°, +12°, +15°, +18° in varus placement and -3°, -6°, -9°, -12°, -15°, -18° in valgus placement has been developed in this study. The study has simulated two loading & boundary conditions namely, normal walking condition and sideway fall condition. The effect of different RHA implant placements on the Drucker-Prager stress distribution and femoral bone strain was observed. The risk of femoral bone fracture associated with the implant placement was then predicted using element failure criterion. The results obtained show that the femoral bone models within the valgus implant placement were produced a high fracture strength as compared to the straight implant and varus implant placements. For the case of normal walking, the fracture strength of the femur bone was decreasing as the implant being oriented more towards varus placement with the lowest fracture strength obtained at the femur implanted with varus +18° placement. The fracture formation occurred at the neck area of the femur. For the case of sideway fall, femoral bone that implanted in varus placement category shows a higher risk towards bone fracture. The fracture formation is predicted to occur at the neck and trochanteric area of the femur. The findings in this study suggest that the RHA implant should be placed slightly in valgus placement or as much valgus as possible during the intra-operative session according to the patient’s bone conditions. 2020-03 Thesis https://ir.uitm.edu.my/id/eprint/59594/ https://ir.uitm.edu.my/id/eprint/59594/1/59594.pdf text en public masters Universiti Teknologi MARA Faculty of Mechanical Engineering Abdullah, Abdul Halim (Ts. Dr.) Mitsugu, Todo (Associate Professor Dr.)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Abdullah, Abdul Halim (Ts. Dr.)
Mitsugu, Todo (Associate Professor Dr.)
topic Medical technology
spellingShingle Medical technology
Nor Izmin, Nor Aiman
Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
description Resurfacing Hip Arthroplasty (RHA) is a hip replacement method that is widely known nowadays. This method usually applied to the hip disease patients who are in the late stage condition. RHA method is most recommended to the young and active patients since high successful rate was recorded to these group of candidates. However, the complication of femoral bone fracture often happens in this hip replacement method which associated with the implant positioning. The objective of this study is to quantify the effects of RHA implant placement towards the bone adaptation for prediction of femoral bone fracture risk by using finite element analysis. Finite element analysis was conducted to predict the damage formation of the bone model based on the computed tomography (CT) image of a patient. A 3D inhomogeneous bone model was developed from computed tomography (CT) image of a 47 years old patient with a hip osteoarthritis disease by using a biomechanical modelling software, Mechanical Finder. The material properties used for the RHA implant model was based on the properties of cobalt-chromium (CoCr). Straight implant placement was firstly developed by referring to the natural shaft-neck axis of the femoral bone, before generating several implant placement in varus and valgus. 13 implanted femur models with implant angle +3°, +6°, +9°, +12°, +15°, +18° in varus placement and -3°, -6°, -9°, -12°, -15°, -18° in valgus placement has been developed in this study. The study has simulated two loading & boundary conditions namely, normal walking condition and sideway fall condition. The effect of different RHA implant placements on the Drucker-Prager stress distribution and femoral bone strain was observed. The risk of femoral bone fracture associated with the implant placement was then predicted using element failure criterion. The results obtained show that the femoral bone models within the valgus implant placement were produced a high fracture strength as compared to the straight implant and varus implant placements. For the case of normal walking, the fracture strength of the femur bone was decreasing as the implant being oriented more towards varus placement with the lowest fracture strength obtained at the femur implanted with varus +18° placement. The fracture formation occurred at the neck area of the femur. For the case of sideway fall, femoral bone that implanted in varus placement category shows a higher risk towards bone fracture. The fracture formation is predicted to occur at the neck and trochanteric area of the femur. The findings in this study suggest that the RHA implant should be placed slightly in valgus placement or as much valgus as possible during the intra-operative session according to the patient’s bone conditions.
format Thesis
qualification_level Master's degree
author Nor Izmin, Nor Aiman
author_facet Nor Izmin, Nor Aiman
author_sort Nor Izmin, Nor Aiman
title Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
title_short Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
title_full Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
title_fullStr Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
title_full_unstemmed Effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / Nor Aiman Nor Izmin
title_sort effects of the implant placement to the risk of femoral bone fracture in resurfacing hip arthroplasty / nor aiman nor izmin
granting_institution Universiti Teknologi MARA
granting_department Faculty of Mechanical Engineering
publishDate 2020
url https://ir.uitm.edu.my/id/eprint/59594/1/59594.pdf
_version_ 1783735042649882624