The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah

The idea of natural lighting is to provide daylighting to the building area. Daylight is determined by the local climate and is influenced by factors, such as orientation, building surroundings, and location, during the first stage of building construction. Implementing natural light design to a...

Full description

Saved in:
Bibliographic Details
Main Author: Wan Abdullah, Wan Nur Hanani
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/60378/1/60378.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.60378
record_format uketd_dc
spelling my-uitm-ir.603782022-05-26T03:34:58Z The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah 2021-07 Wan Abdullah, Wan Nur Hanani Daylighting. Illumination of buildings The idea of natural lighting is to provide daylighting to the building area. Daylight is determined by the local climate and is influenced by factors, such as orientation, building surroundings, and location, during the first stage of building construction. Implementing natural light design to a building is challenging, and educational buildings involve optimal lighting conditions. There is a significant expense pressure as most educational buildings use high lighting energy due to occupants’ daily working hours usage. This research investigates the daylighting design failures in existing educational buildings at UiTM Perak. Daylighting design failure occurs when it wastes the capability to achieve its intended function. Therefore, this research aims to determine the actual illuminance level in the studied classrooms to ensure that existing classrooms have insufficient indoor daylight and identify different classroom characteristics contributing to daylighting design failures. At the end of this research, it focuses on recommending the best daylighting design solutions for classroom spaces. This research employed a quantitative method, a fieldwork measurement and classroom characterisation observation as the research methodology. Thus, a series of fieldwork measurements were performed in the studied classrooms for five (5) days to determine the classroom’s actual illuminance level. This research measured indoor and outdoor lighting levels to evaluate the classrooms’ daylighting levels in different building forms. Hence, the Systematic Literature Review (SLR) method was used to identify factors contributing to inefficient daylighting design in studied classrooms. Six (6) factors affect daylighting performance, and those factors were used to conduct an observation. Fieldwork evaluation revealed that two out of three studied classrooms did not achieve the indoor illuminance level as stated in MS1525:2019. It was noticed that, overall, one of the studied classrooms achieved an acceptable range of Daylight Factor (DF). However, the other two classrooms were below the recommendations. The results found that the illuminance levels were not within the standard due to several factors contributing to the classroom design characteristics. Based on the observation analysis, the main factors contributing to design failures are poor classrooms orientation, double-loaded building with single-sided windows, small glazing area, low window placement, inappropriate glazing properties, and low light reflectance value. The classroom characteristics provide an advantage to achieve an optimum value of daylighting. This research contributes to the best practices of daylighting design for classrooms by providing recommendations to solve daylighting design failures in the existing classrooms. Finally, it is hoped this research will contribute to the discovery of problems impacting poor daylight efficiency in educational buildings, which can be used to foster a greater understanding of the benefits of daylighting for occupants. 2021-07 Thesis https://ir.uitm.edu.my/id/eprint/60378/ https://ir.uitm.edu.my/id/eprint/60378/1/60378.pdf text en public masters Universiti Teknologi MARA Faculty of Architecture, Planning and Surveying Abdul Tharim, Asniza Hamimi (Dr.)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Abdul Tharim, Asniza Hamimi (Dr.)
topic Daylighting
Illumination of buildings
spellingShingle Daylighting
Illumination of buildings
Wan Abdullah, Wan Nur Hanani
The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
description The idea of natural lighting is to provide daylighting to the building area. Daylight is determined by the local climate and is influenced by factors, such as orientation, building surroundings, and location, during the first stage of building construction. Implementing natural light design to a building is challenging, and educational buildings involve optimal lighting conditions. There is a significant expense pressure as most educational buildings use high lighting energy due to occupants’ daily working hours usage. This research investigates the daylighting design failures in existing educational buildings at UiTM Perak. Daylighting design failure occurs when it wastes the capability to achieve its intended function. Therefore, this research aims to determine the actual illuminance level in the studied classrooms to ensure that existing classrooms have insufficient indoor daylight and identify different classroom characteristics contributing to daylighting design failures. At the end of this research, it focuses on recommending the best daylighting design solutions for classroom spaces. This research employed a quantitative method, a fieldwork measurement and classroom characterisation observation as the research methodology. Thus, a series of fieldwork measurements were performed in the studied classrooms for five (5) days to determine the classroom’s actual illuminance level. This research measured indoor and outdoor lighting levels to evaluate the classrooms’ daylighting levels in different building forms. Hence, the Systematic Literature Review (SLR) method was used to identify factors contributing to inefficient daylighting design in studied classrooms. Six (6) factors affect daylighting performance, and those factors were used to conduct an observation. Fieldwork evaluation revealed that two out of three studied classrooms did not achieve the indoor illuminance level as stated in MS1525:2019. It was noticed that, overall, one of the studied classrooms achieved an acceptable range of Daylight Factor (DF). However, the other two classrooms were below the recommendations. The results found that the illuminance levels were not within the standard due to several factors contributing to the classroom design characteristics. Based on the observation analysis, the main factors contributing to design failures are poor classrooms orientation, double-loaded building with single-sided windows, small glazing area, low window placement, inappropriate glazing properties, and low light reflectance value. The classroom characteristics provide an advantage to achieve an optimum value of daylighting. This research contributes to the best practices of daylighting design for classrooms by providing recommendations to solve daylighting design failures in the existing classrooms. Finally, it is hoped this research will contribute to the discovery of problems impacting poor daylight efficiency in educational buildings, which can be used to foster a greater understanding of the benefits of daylighting for occupants.
format Thesis
qualification_level Master's degree
author Wan Abdullah, Wan Nur Hanani
author_facet Wan Abdullah, Wan Nur Hanani
author_sort Wan Abdullah, Wan Nur Hanani
title The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
title_short The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
title_full The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
title_fullStr The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
title_full_unstemmed The determination of daylighting design failure factors in educational buildings / Wan Nur Hanani Wan Abdullah
title_sort determination of daylighting design failure factors in educational buildings / wan nur hanani wan abdullah
granting_institution Universiti Teknologi MARA
granting_department Faculty of Architecture, Planning and Surveying
publishDate 2021
url https://ir.uitm.edu.my/id/eprint/60378/1/60378.pdf
_version_ 1783735121041424384