Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali

Orthodontic treatment generally emphasises heavily on anchorage reinforcement and the success of its treatment highly relies on sufficient anchorage. Orthodontic Mini Implants (MIs) are an example of Temporary Anchorage Devices (TADs) that are often used in orthodontics, due to their benefits. Howev...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Ali, Nor Dayana
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/60877/1/60877.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.60877
record_format uketd_dc
spelling my-uitm-ir.608772022-06-02T08:27:12Z Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali 2020-10 Mohd Ali, Nor Dayana Orthodontics Orthodontic treatment generally emphasises heavily on anchorage reinforcement and the success of its treatment highly relies on sufficient anchorage. Orthodontic Mini Implants (MIs) are an example of Temporary Anchorage Devices (TADs) that are often used in orthodontics, due to their benefits. However, there are some disadvantages associated with their use such as pain and ulceration due to the constant impingement of the MI head on the buccal mucosa. Several methods and materials have been proposed and marketed that claimed to help reduce the pain or eliminate trauma, however, none has proven its claims clinically. Thus, our objectives were to evaluate and compare pain levels and the oral health related quality of life (OHRQoL) between subjects using the Soft Flow (SF) covers, Composite (CR) covers and Control (no cover). Another objective was to compare the cost effectiveness of the two cover types. Methodology: The study design is a prospective parallel randomised clinical trial. Thirty-nine patients were recruited and randomised into three groups: Control – Ctrl (13 subjects); Soft Flow – SF (13 subjects) and Composite – CR (13 subject). Subjects were given a booklet (Pain diary) that includes the demographic details, Numeric Pain Rating Scale (NRS) and a modified Short Oral Health Impact Profile (S-OHIP14) questionnaire. The NRS consists of an 11-points scale from 0 (No pain) to 10 (Severe pain). The post-operative pain was measured using NRS at various time points starting from T0 (Immediately after insertion) until TD30 (30 days after insertion). The modified S-OHIP-14 questionnaire was used to evaluate patients’ quality of life and was administered prior to the MI insertion (Baseline, B0) and at TD30. Results: There was a statistically significant difference in the pain scores between the Ctrl and SF groups (P=0.002) where by the Ctrl group showed higher pain levels when compared with SF. However, there were no significant difference between SF and CR groups as well as Ctrl and CR groups. With regards to the OHRQoL, Ctrl group showed statistically significant increase in the functional limitation and physical pain domain (P=0.012, P= 0.022) and CR group in the functional limitation domain (P=0.02). Conclusion: Pain levels of those with MI cover were generally lower than those without a cover. There was also a significant reduction in the OHRQoL for the Ctrl group in the functional limitation and physical pain domain and CR group in the functional limitation domain. 2020-10 Thesis https://ir.uitm.edu.my/id/eprint/60877/ https://ir.uitm.edu.my/id/eprint/60877/1/60877.pdf text en public phd doctoral Universiti Teknologi MARA Faculty of Dentistry Hafizan Norman, Noraina (Dr.)
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Hafizan Norman, Noraina (Dr.)
topic Orthodontics
spellingShingle Orthodontics
Mohd Ali, Nor Dayana
Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
description Orthodontic treatment generally emphasises heavily on anchorage reinforcement and the success of its treatment highly relies on sufficient anchorage. Orthodontic Mini Implants (MIs) are an example of Temporary Anchorage Devices (TADs) that are often used in orthodontics, due to their benefits. However, there are some disadvantages associated with their use such as pain and ulceration due to the constant impingement of the MI head on the buccal mucosa. Several methods and materials have been proposed and marketed that claimed to help reduce the pain or eliminate trauma, however, none has proven its claims clinically. Thus, our objectives were to evaluate and compare pain levels and the oral health related quality of life (OHRQoL) between subjects using the Soft Flow (SF) covers, Composite (CR) covers and Control (no cover). Another objective was to compare the cost effectiveness of the two cover types. Methodology: The study design is a prospective parallel randomised clinical trial. Thirty-nine patients were recruited and randomised into three groups: Control – Ctrl (13 subjects); Soft Flow – SF (13 subjects) and Composite – CR (13 subject). Subjects were given a booklet (Pain diary) that includes the demographic details, Numeric Pain Rating Scale (NRS) and a modified Short Oral Health Impact Profile (S-OHIP14) questionnaire. The NRS consists of an 11-points scale from 0 (No pain) to 10 (Severe pain). The post-operative pain was measured using NRS at various time points starting from T0 (Immediately after insertion) until TD30 (30 days after insertion). The modified S-OHIP-14 questionnaire was used to evaluate patients’ quality of life and was administered prior to the MI insertion (Baseline, B0) and at TD30. Results: There was a statistically significant difference in the pain scores between the Ctrl and SF groups (P=0.002) where by the Ctrl group showed higher pain levels when compared with SF. However, there were no significant difference between SF and CR groups as well as Ctrl and CR groups. With regards to the OHRQoL, Ctrl group showed statistically significant increase in the functional limitation and physical pain domain (P=0.012, P= 0.022) and CR group in the functional limitation domain (P=0.02). Conclusion: Pain levels of those with MI cover were generally lower than those without a cover. There was also a significant reduction in the OHRQoL for the Ctrl group in the functional limitation and physical pain domain and CR group in the functional limitation domain.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Mohd Ali, Nor Dayana
author_facet Mohd Ali, Nor Dayana
author_sort Mohd Ali, Nor Dayana
title Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
title_short Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
title_full Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
title_fullStr Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
title_full_unstemmed Clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / Nor Dayana Mohd Ali
title_sort clinical assessment of orthodontic mini implant covers and their effect on the oral health quality of life: a randomised controlled trial / nor dayana mohd ali
granting_institution Universiti Teknologi MARA
granting_department Faculty of Dentistry
publishDate 2020
url https://ir.uitm.edu.my/id/eprint/60877/1/60877.pdf
_version_ 1783735180510363648