Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli

This study focused on designing and simulating alternative air inlet geometry of air cooling on a single channel (SSI) and multichannel (MS60) channel types for PEM fuel cell bipolar plate with a power rating of 3kW. Two air inlet geometry designs generated are nozzle type with three different angle...

Full description

Saved in:
Bibliographic Details
Main Author: Ramli, Nur Hamiza
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/67303/1/67303.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.67303
record_format uketd_dc
spelling my-uitm-ir.673032022-09-23T03:18:14Z Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli 2010 Ramli, Nur Hamiza Heating and ventilation. Air conditioning This study focused on designing and simulating alternative air inlet geometry of air cooling on a single channel (SSI) and multichannel (MS60) channel types for PEM fuel cell bipolar plate with a power rating of 3kW. Two air inlet geometry designs generated are nozzle type with three different angles and quarter circle type with three different radiuses. The designs were generated using CATIA software and simulation work using STAR-CCM; a CFD (Computational Fluid Dynamics) software type. The simulations were conducted to observe and determine whether these new inlet geometry designs give some improvement and better results in heat transfer rate of fuel cell compare to conventional design. The higher heat transfer rate of the fuel cell results in higher heat transfer efficiency of the fuel cell. Each design was simulated in four different velocities from 0.5 m/s to 3.0 m/s with similar boundary conditions such as laminar flow, air inlet temperature, and constant heat flux. The simulation results show that each design generates different flow field that gives higher heat transfer rate than conventional design. The simulated air inlet geometry shows 0.04% to 24.6% improvement on heat transfer rate of a bipolar plate fuel cell. The best design of air inlet geometry is 15 degree nozzle type. 2010 Thesis https://ir.uitm.edu.my/id/eprint/67303/ https://ir.uitm.edu.my/id/eprint/67303/1/67303.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Mechanical Engineering Atan, Rahim
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Atan, Rahim
topic Heating and ventilation
Air conditioning
spellingShingle Heating and ventilation
Air conditioning
Ramli, Nur Hamiza
Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
description This study focused on designing and simulating alternative air inlet geometry of air cooling on a single channel (SSI) and multichannel (MS60) channel types for PEM fuel cell bipolar plate with a power rating of 3kW. Two air inlet geometry designs generated are nozzle type with three different angles and quarter circle type with three different radiuses. The designs were generated using CATIA software and simulation work using STAR-CCM; a CFD (Computational Fluid Dynamics) software type. The simulations were conducted to observe and determine whether these new inlet geometry designs give some improvement and better results in heat transfer rate of fuel cell compare to conventional design. The higher heat transfer rate of the fuel cell results in higher heat transfer efficiency of the fuel cell. Each design was simulated in four different velocities from 0.5 m/s to 3.0 m/s with similar boundary conditions such as laminar flow, air inlet temperature, and constant heat flux. The simulation results show that each design generates different flow field that gives higher heat transfer rate than conventional design. The simulated air inlet geometry shows 0.04% to 24.6% improvement on heat transfer rate of a bipolar plate fuel cell. The best design of air inlet geometry is 15 degree nozzle type.
format Thesis
qualification_level Bachelor degree
author Ramli, Nur Hamiza
author_facet Ramli, Nur Hamiza
author_sort Ramli, Nur Hamiza
title Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
title_short Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
title_full Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
title_fullStr Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
title_full_unstemmed Analysis of cooling performance for air cooling channels of a PEM cell using CFD: inlet geometry design / Nur Hamiza Ramli
title_sort analysis of cooling performance for air cooling channels of a pem cell using cfd: inlet geometry design / nur hamiza ramli
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Mechanical Engineering
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/67303/1/67303.pdf