Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman

My Final Project course under Prof. Dr. Azni Zain Ahmed is to perform a field evaluation and an analysis of energy efficiency by using daylighting technology as the main source of illumination and as a replacement for the usage of conventional artificial light due to energy savings at the Wilayah Mo...

Full description

Saved in:
Bibliographic Details
Main Author: Othman, Abdul Halim
Format: Thesis
Language:English
Published: 2002
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/76483/1/76483.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.76483
record_format uketd_dc
spelling my-uitm-ir.764832023-09-12T07:47:49Z Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman 2002 Othman, Abdul Halim Illumination. Lighting My Final Project course under Prof. Dr. Azni Zain Ahmed is to perform a field evaluation and an analysis of energy efficiency by using daylighting technology as the main source of illumination and as a replacement for the usage of conventional artificial light due to energy savings at the Wilayah Mosque, Jalan Duta, Kuala Lumpur. The efficiency of the daylight illumination and indoor thermal comfort, which spread out in the prayer hall for prayer activities, reading and gathering is the main objective of my analysis. My methodology is to measure indoor illumination by using lux meter for direct and global illumination, indoor thermal comfort such as relative humidity, temperature, wind speed by using RH meter, thermocouple and anemometer. This evaluation and analysis were performed at the main prayer hall only. From my analysis it was found that the daylighting system functioned efficiently to ligl1t up most of the entire prayer hall. This illumination level was within the accepted level and more than enough for religious activities following Malaysia Standard MS 1525:2001 (page 16). It was found that air conditioning system provided good level of relative humidity due to human comfort for sweat evaporation process but the temperature was too cold. New settings of air condition temperature are needed to provide better condition for any religious activities. 2002 Thesis https://ir.uitm.edu.my/id/eprint/76483/ https://ir.uitm.edu.my/id/eprint/76483/1/76483.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Mechanical Engineering Ahmed, Azni Zain
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Ahmed, Azni Zain
topic Illumination
Lighting
spellingShingle Illumination
Lighting
Othman, Abdul Halim
Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
description My Final Project course under Prof. Dr. Azni Zain Ahmed is to perform a field evaluation and an analysis of energy efficiency by using daylighting technology as the main source of illumination and as a replacement for the usage of conventional artificial light due to energy savings at the Wilayah Mosque, Jalan Duta, Kuala Lumpur. The efficiency of the daylight illumination and indoor thermal comfort, which spread out in the prayer hall for prayer activities, reading and gathering is the main objective of my analysis. My methodology is to measure indoor illumination by using lux meter for direct and global illumination, indoor thermal comfort such as relative humidity, temperature, wind speed by using RH meter, thermocouple and anemometer. This evaluation and analysis were performed at the main prayer hall only. From my analysis it was found that the daylighting system functioned efficiently to ligl1t up most of the entire prayer hall. This illumination level was within the accepted level and more than enough for religious activities following Malaysia Standard MS 1525:2001 (page 16). It was found that air conditioning system provided good level of relative humidity due to human comfort for sweat evaporation process but the temperature was too cold. New settings of air condition temperature are needed to provide better condition for any religious activities.
format Thesis
qualification_level Bachelor degree
author Othman, Abdul Halim
author_facet Othman, Abdul Halim
author_sort Othman, Abdul Halim
title Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
title_short Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
title_full Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
title_fullStr Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
title_full_unstemmed Daylighting technology for energy efficiency and thermal comfort for Wilayah Mosque in Kuala Lumpur / Abdul Halim Othman
title_sort daylighting technology for energy efficiency and thermal comfort for wilayah mosque in kuala lumpur / abdul halim othman
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Mechanical Engineering
publishDate 2002
url https://ir.uitm.edu.my/id/eprint/76483/1/76483.pdf