A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin
Freescale Semiconductor (FSL's) primary concern in respect of removal of the Power Conditioning Units (PCUs) is the risk of production loss through the exposure of the tester and handler to unacceptable levels of power quality, voltage sag, and harmonic. In recent years, with the increase numbe...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | https://ir.uitm.edu.my/id/eprint/77920/1/77920.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-uitm-ir.77920 |
---|---|
record_format |
uketd_dc |
spelling |
my-uitm-ir.779202023-07-26T00:41:25Z A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin 2013 Zainal Abidin, Md Raziff TK Electrical engineering. Electronics. Nuclear engineering Freescale Semiconductor (FSL's) primary concern in respect of removal of the Power Conditioning Units (PCUs) is the risk of production loss through the exposure of the tester and handler to unacceptable levels of power quality, voltage sag, and harmonic. In recent years, with the increase number of testers drawing non-sinusoidal currents, power quality distortion has become a serious problem in FSL electrical power systems. In this paper, to access the impact voltage sag on the selected testers and their associated handler, evaluations of harmonic and the performance of the power conditioner have been studied. Then after theoretical study, harmonic and several power quality indices have been measured in a factory. The measurements show that based on the results of the tests conducted both the Piller and Datawave Power Conditioning Units (PCUs) offer good isolation of the input power supply from the harmonic loads and vice versa. Both also offer voltage sag correction and harmonic mitigation. 2013 Thesis https://ir.uitm.edu.my/id/eprint/77920/ https://ir.uitm.edu.my/id/eprint/77920/1/77920.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Che Mat Harris, Harizan |
institution |
Universiti Teknologi MARA |
collection |
UiTM Institutional Repository |
language |
English |
advisor |
Che Mat Harris, Harizan |
topic |
TK Electrical engineering Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering Electronics Nuclear engineering Zainal Abidin, Md Raziff A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
description |
Freescale Semiconductor (FSL's) primary concern in respect of removal of the Power Conditioning Units (PCUs) is the risk of production loss through the exposure of the tester and handler to unacceptable levels of power quality, voltage sag, and harmonic. In recent years, with the increase number of testers drawing non-sinusoidal currents, power quality distortion has become a serious problem in FSL electrical power systems. In this paper, to access the impact voltage sag on the selected testers and their associated handler, evaluations of harmonic and the performance of the power conditioner have been studied. Then after theoretical study, harmonic and several power quality indices have been measured in a factory. The measurements show that based on the results of the tests conducted both the Piller and Datawave Power Conditioning Units (PCUs) offer good isolation of the input power supply from the harmonic loads and vice versa. Both also offer voltage sag correction and harmonic mitigation. |
format |
Thesis |
qualification_level |
Bachelor degree |
author |
Zainal Abidin, Md Raziff |
author_facet |
Zainal Abidin, Md Raziff |
author_sort |
Zainal Abidin, Md Raziff |
title |
A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
title_short |
A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
title_full |
A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
title_fullStr |
A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
title_full_unstemmed |
A case study: the performance of power conditioning unit in freescale semiconductor Sg.Way Petaling Jaya Selangor / Md Raziff Zainal Abidin |
title_sort |
case study: the performance of power conditioning unit in freescale semiconductor sg.way petaling jaya selangor / md raziff zainal abidin |
granting_institution |
Universiti Teknologi MARA (UiTM) |
granting_department |
Faculty of Electrical Engineering |
publishDate |
2013 |
url |
https://ir.uitm.edu.my/id/eprint/77920/1/77920.pdf |
_version_ |
1783736181689679872 |