Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli

Impedance pump is a valve less pump emerging from the blood circulatory system of human that function without blade or propeller to transfer fluid. The impedance pump offers good characteristics as valve less pump to overcome clinical issues such as blood cell damaged by the rotational blades used i...

Full description

Saved in:
Bibliographic Details
Main Author: Rosli, Nazirul Izzati
Format: Thesis
Language:English
Published: 2019
Subjects:
Online Access:https://ir.uitm.edu.my/id/eprint/84314/1/84314.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.84314
record_format uketd_dc
spelling my-uitm-ir.843142024-07-11T08:46:24Z Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli 2019 Rosli, Nazirul Izzati QM Human anatomy Specialties of internal medicine Impedance pump is a valve less pump emerging from the blood circulatory system of human that function without blade or propeller to transfer fluid. The impedance pump offers good characteristics as valve less pump to overcome clinical issues such as blood cell damaged by the rotational blades used in mechanical circulatory support system. Thus, this research is to analyse the flow rate performance in valve less impedance pumps which generates a unidirectional flow of fluid around closed loop of soft viscoelastic tubing inspired by Liebau phenomenon. An experimental setup was prepared that consist of rigid and elastic tube with outer compression mechanism to generate wave flow at various frequencies. Parameters such as frequency, elastic tube diameter, pinching position and fluid viscosity were analysed to describe the influence on the flow rate throughout the experiment. Then, double compression on elastic tube section was performed to compare with single compression experiment. The difference on the flow rate was discussed further. To provide uniform and sequence compression, a DC electric motor was utilized as to convert rotational to vertical pinching. A long elastic balloon was used for elastic section with various diameter (32 mm, 16 mm, and 10 mm). 2019 Thesis https://ir.uitm.edu.my/id/eprint/84314/ https://ir.uitm.edu.my/id/eprint/84314/1/84314.pdf text en public masters Universiti Teknologi MARA (UiTM) Faculty of Mechanical Engineering Abd Razak, Azli
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Abd Razak, Azli
topic QM Human anatomy
Specialties of internal medicine
spellingShingle QM Human anatomy
Specialties of internal medicine
Rosli, Nazirul Izzati
Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
description Impedance pump is a valve less pump emerging from the blood circulatory system of human that function without blade or propeller to transfer fluid. The impedance pump offers good characteristics as valve less pump to overcome clinical issues such as blood cell damaged by the rotational blades used in mechanical circulatory support system. Thus, this research is to analyse the flow rate performance in valve less impedance pumps which generates a unidirectional flow of fluid around closed loop of soft viscoelastic tubing inspired by Liebau phenomenon. An experimental setup was prepared that consist of rigid and elastic tube with outer compression mechanism to generate wave flow at various frequencies. Parameters such as frequency, elastic tube diameter, pinching position and fluid viscosity were analysed to describe the influence on the flow rate throughout the experiment. Then, double compression on elastic tube section was performed to compare with single compression experiment. The difference on the flow rate was discussed further. To provide uniform and sequence compression, a DC electric motor was utilized as to convert rotational to vertical pinching. A long elastic balloon was used for elastic section with various diameter (32 mm, 16 mm, and 10 mm).
format Thesis
qualification_level Master's degree
author Rosli, Nazirul Izzati
author_facet Rosli, Nazirul Izzati
author_sort Rosli, Nazirul Izzati
title Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
title_short Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
title_full Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
title_fullStr Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
title_full_unstemmed Analysis on the effects of pulsation induced flow in mechanical circulatory support system / Nazirul Izzati Rosli
title_sort analysis on the effects of pulsation induced flow in mechanical circulatory support system / nazirul izzati rosli
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Mechanical Engineering
publishDate 2019
url https://ir.uitm.edu.my/id/eprint/84314/1/84314.pdf
_version_ 1804889721055215616