Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa

The switching of shunt capacitor banks at utility substations and on distribution feeders creates voltage and current transients in the power system which may be damaging to power system equipment. Transient over voltages due to the energizing of capacitor banks are the most common source of over vo...

Full description

Saved in:
Bibliographic Details
Main Author: Mustafa, Muhammad Hasanol
Format: Thesis
Language:English
Published: 2009
Online Access:https://ir.uitm.edu.my/id/eprint/84472/1/84472.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.84472
record_format uketd_dc
spelling my-uitm-ir.844722024-02-23T03:27:45Z Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa 2009 Mustafa, Muhammad Hasanol The switching of shunt capacitor banks at utility substations and on distribution feeders creates voltage and current transients in the power system which may be damaging to power system equipment. Transient over voltages due to the energizing of capacitor banks are the most common source of over voltages on many power systems. The high incidence of capacitor-switching induced over voltages is a result of a marked increase in the number of shunt capacitor banks used on transmission and distribution systems as well as the frequent switching thereof (in most instances at least one close open operation per day).The utility industry has undergone many changes over the years and one of the major power quality problems to utilities and their consumers is the transient voltages that are a result of capacitor bank switching. The energizing transient is important because it is one of the most frequent system switching operations. Distorted waveforms along with the harmonic pollution introduced to the system, may cause undesirable effects such as instability of converter control, increased system losses, an increase in motor losses, overheating in transformers, switchgear, capacitors and miss operation of protective relays, fuses, and metering devices. This paper explores the suitable calculated value for reactor in capacitor switching and the effect of inrush current in power distribution substation. 2009 Thesis https://ir.uitm.edu.my/id/eprint/84472/ https://ir.uitm.edu.my/id/eprint/84472/1/84472.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Nik Ismail, Nik Fasdi
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Nik Ismail, Nik Fasdi
description The switching of shunt capacitor banks at utility substations and on distribution feeders creates voltage and current transients in the power system which may be damaging to power system equipment. Transient over voltages due to the energizing of capacitor banks are the most common source of over voltages on many power systems. The high incidence of capacitor-switching induced over voltages is a result of a marked increase in the number of shunt capacitor banks used on transmission and distribution systems as well as the frequent switching thereof (in most instances at least one close open operation per day).The utility industry has undergone many changes over the years and one of the major power quality problems to utilities and their consumers is the transient voltages that are a result of capacitor bank switching. The energizing transient is important because it is one of the most frequent system switching operations. Distorted waveforms along with the harmonic pollution introduced to the system, may cause undesirable effects such as instability of converter control, increased system losses, an increase in motor losses, overheating in transformers, switchgear, capacitors and miss operation of protective relays, fuses, and metering devices. This paper explores the suitable calculated value for reactor in capacitor switching and the effect of inrush current in power distribution substation.
format Thesis
qualification_level Bachelor degree
author Mustafa, Muhammad Hasanol
spellingShingle Mustafa, Muhammad Hasanol
Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
author_facet Mustafa, Muhammad Hasanol
author_sort Mustafa, Muhammad Hasanol
title Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
title_short Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
title_full Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
title_fullStr Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
title_full_unstemmed Determining inrush current limiting reactor for capacitor switching using PSCAD / Muhammad Hasanol Mustafa
title_sort determining inrush current limiting reactor for capacitor switching using pscad / muhammad hasanol mustafa
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Electrical Engineering
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/84472/1/84472.pdf
_version_ 1794192004358340608