Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah

This paper presents the transmission line compensation to improve the system stability in power system. In order to achieve the objective, three methods of line compensation were implemented, series capacitor, shunt capacitor and shunt reactor to improve the voltage stability by looking at the volta...

Full description

Saved in:
Bibliographic Details
Main Author: Abdullah, Muhamad Qamarul Hafiz
Format: Thesis
Language:English
Published: 2009
Online Access:https://ir.uitm.edu.my/id/eprint/84488/1/84488.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.84488
record_format uketd_dc
spelling my-uitm-ir.844882024-02-19T04:00:33Z Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah 2009 Abdullah, Muhamad Qamarul Hafiz This paper presents the transmission line compensation to improve the system stability in power system. In order to achieve the objective, three methods of line compensation were implemented, series capacitor, shunt capacitor and shunt reactor to improve the voltage stability by looking at the voltage regulation. The location of weakest transmission line was identified using the sensitivity index (SI). The proposed method was applied to a 30 busbar IEEE systems to show its feasibility and capability. All simulation was done using the MATLAB version 7.5 programming. 2009 Thesis https://ir.uitm.edu.my/id/eprint/84488/ https://ir.uitm.edu.my/id/eprint/84488/1/84488.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Wan Abdullah, Wan Norainin
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Wan Abdullah, Wan Norainin
description This paper presents the transmission line compensation to improve the system stability in power system. In order to achieve the objective, three methods of line compensation were implemented, series capacitor, shunt capacitor and shunt reactor to improve the voltage stability by looking at the voltage regulation. The location of weakest transmission line was identified using the sensitivity index (SI). The proposed method was applied to a 30 busbar IEEE systems to show its feasibility and capability. All simulation was done using the MATLAB version 7.5 programming.
format Thesis
qualification_level Bachelor degree
author Abdullah, Muhamad Qamarul Hafiz
spellingShingle Abdullah, Muhamad Qamarul Hafiz
Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
author_facet Abdullah, Muhamad Qamarul Hafiz
author_sort Abdullah, Muhamad Qamarul Hafiz
title Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
title_short Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
title_full Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
title_fullStr Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
title_full_unstemmed Transmission line compensation for power system stability improvement / Muhamad Qamarul Hafiz Abdullah
title_sort transmission line compensation for power system stability improvement / muhamad qamarul hafiz abdullah
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Electrical Engineering
publishDate 2009
url https://ir.uitm.edu.my/id/eprint/84488/1/84488.pdf
_version_ 1794192007268139008