Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak

In power quality, voltage sag is the one of the problem issue in the power distribution system and Dynamic voltage Restorer (DVR) is used for mitigation of the sag problem. Voltage sags are normally caused by switching factors or faults at the transmission line. The fault can be occurring in terms o...

Full description

Saved in:
Bibliographic Details
Main Author: Sahak, Muhammad Salman
Format: Thesis
Language:English
Published: 2010
Online Access:https://ir.uitm.edu.my/id/eprint/84793/1/84793.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.84793
record_format uketd_dc
spelling my-uitm-ir.847932024-02-23T03:56:37Z Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak 2010 Sahak, Muhammad Salman In power quality, voltage sag is the one of the problem issue in the power distribution system and Dynamic voltage Restorer (DVR) is used for mitigation of the sag problem. Voltage sags are normally caused by switching factors or faults at the transmission line. The fault can be occurring in terms of balance and unbalanced fault. Unbalance fault sag are commonly occur in the distribution system while the balance faults often seen as the worst case and however it seldom occurs. Since voltage sag is creating worse affect, the researches almost keen to find the solution for this problem. According to this problem an effective devices has been designed in order to mitigate the voltage sag problems. Nowadays, a lot of devices have been developed to mitigate voltage sag such as Dynamic Voltage Restorer (DVR), Voltage Dip Compensator (VDC), and Voltage Dip Proofing Inverter (DIP). In this study, focus is given only on the DVR system that will be simulated by using MATLAB SIMULINK software in order to mitigate and overcome the immunization of the sag problem that is occurred by the faults. This device will be connected in series to the problem circuit and it will improve the problem of the sag. At the same time simple calculation for voltage sag and voltage injection by DVR system also described. Finally the DVR system also will improved by increasing the value of MVA rating and secondary transformer in certain specific condition as to ensure that this device has more opportunity to mitigate voltage sag in long duration. The increasing of the capability of DVR also is very important for future development in order to analyze the impact of the DVR to the power distribution system. 2010 Thesis https://ir.uitm.edu.my/id/eprint/84793/ https://ir.uitm.edu.my/id/eprint/84793/1/84793.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Hamzah, Noraliza
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Hamzah, Noraliza
description In power quality, voltage sag is the one of the problem issue in the power distribution system and Dynamic voltage Restorer (DVR) is used for mitigation of the sag problem. Voltage sags are normally caused by switching factors or faults at the transmission line. The fault can be occurring in terms of balance and unbalanced fault. Unbalance fault sag are commonly occur in the distribution system while the balance faults often seen as the worst case and however it seldom occurs. Since voltage sag is creating worse affect, the researches almost keen to find the solution for this problem. According to this problem an effective devices has been designed in order to mitigate the voltage sag problems. Nowadays, a lot of devices have been developed to mitigate voltage sag such as Dynamic Voltage Restorer (DVR), Voltage Dip Compensator (VDC), and Voltage Dip Proofing Inverter (DIP). In this study, focus is given only on the DVR system that will be simulated by using MATLAB SIMULINK software in order to mitigate and overcome the immunization of the sag problem that is occurred by the faults. This device will be connected in series to the problem circuit and it will improve the problem of the sag. At the same time simple calculation for voltage sag and voltage injection by DVR system also described. Finally the DVR system also will improved by increasing the value of MVA rating and secondary transformer in certain specific condition as to ensure that this device has more opportunity to mitigate voltage sag in long duration. The increasing of the capability of DVR also is very important for future development in order to analyze the impact of the DVR to the power distribution system.
format Thesis
qualification_level Bachelor degree
author Sahak, Muhammad Salman
spellingShingle Sahak, Muhammad Salman
Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
author_facet Sahak, Muhammad Salman
author_sort Sahak, Muhammad Salman
title Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
title_short Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
title_full Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
title_fullStr Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
title_full_unstemmed Mitigation techniques for voltage SAG in power distribution system by using dynamic voltage restorer / Muhammad Salman Sahak
title_sort mitigation techniques for voltage sag in power distribution system by using dynamic voltage restorer / muhammad salman sahak
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Electrical Engineering
publishDate 2010
url https://ir.uitm.edu.my/id/eprint/84793/1/84793.pdf
_version_ 1794192051360759808