Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab

This thesis presents an automatic voltage stability analysis in the presence of contingency. In this case, the study was conducted under generator and/ or line outage contingency. The study aims to evaluate the bifurcation point when voltage stability is highly affected by reactive power generation...

Full description

Saved in:
Bibliographic Details
Main Author: Ab. Wahab, Nor Ayuni Ahadiah
Format: Thesis
Language:English
Published: 2011
Online Access:https://ir.uitm.edu.my/id/eprint/85174/1/85174.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-uitm-ir.85174
record_format uketd_dc
spelling my-uitm-ir.851742024-02-06T12:06:14Z Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab 2011 Ab. Wahab, Nor Ayuni Ahadiah This thesis presents an automatic voltage stability analysis in the presence of contingency. In this case, the study was conducted under generator and/ or line outage contingency. The study aims to evaluate the bifurcation point when voltage stability is highly affected by reactive power generation saturation phenomena. The reactive power generation saturation of a unit can change the system voltage immediately from stable to unstable. The value is determined using MATLAB programming that uses fast voltage stability index (FVSI) as an indicator. The results of the index before and after the contingency are compared to show the effect of contingency to the system. The method was tested on the IEEE 30-Bus Reliability Test System (RTS) system and results have been compared using the V-Q curves. Results obtained from study would be beneficial as future referring for researchers and students in power system. 2011 Thesis https://ir.uitm.edu.my/id/eprint/85174/ https://ir.uitm.edu.my/id/eprint/85174/1/85174.pdf text en public degree Universiti Teknologi MARA (UiTM) Faculty of Electrical Engineering Musirin, Ismail
institution Universiti Teknologi MARA
collection UiTM Institutional Repository
language English
advisor Musirin, Ismail
description This thesis presents an automatic voltage stability analysis in the presence of contingency. In this case, the study was conducted under generator and/ or line outage contingency. The study aims to evaluate the bifurcation point when voltage stability is highly affected by reactive power generation saturation phenomena. The reactive power generation saturation of a unit can change the system voltage immediately from stable to unstable. The value is determined using MATLAB programming that uses fast voltage stability index (FVSI) as an indicator. The results of the index before and after the contingency are compared to show the effect of contingency to the system. The method was tested on the IEEE 30-Bus Reliability Test System (RTS) system and results have been compared using the V-Q curves. Results obtained from study would be beneficial as future referring for researchers and students in power system.
format Thesis
qualification_level Bachelor degree
author Ab. Wahab, Nor Ayuni Ahadiah
spellingShingle Ab. Wahab, Nor Ayuni Ahadiah
Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
author_facet Ab. Wahab, Nor Ayuni Ahadiah
author_sort Ab. Wahab, Nor Ayuni Ahadiah
title Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
title_short Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
title_full Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
title_fullStr Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
title_full_unstemmed Automatic voltage stability analysis in the presence of contingency / Nor Ayuni Ahadiah Ab. Wahab
title_sort automatic voltage stability analysis in the presence of contingency / nor ayuni ahadiah ab. wahab
granting_institution Universiti Teknologi MARA (UiTM)
granting_department Faculty of Electrical Engineering
publishDate 2011
url https://ir.uitm.edu.my/id/eprint/85174/1/85174.pdf
_version_ 1794192077743980544