2 MHz electrical resistance tomography for static liquid solid profile measurement

Tomography is a technique used to reconstruct cross-sectional image of a pipeline for flow monitoring applications. There are several types of tomography system such as X-ray tomography, ultrasonic tomography, and electrical resistance tomography (ERT). ERT has many advantages compared to other type...

Full description

Saved in:
Bibliographic Details
Main Author: Yasmin, Abdul Wahab
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/31315/1/2%20mhz%20electrical%20resistance%20tomography%20for%20static%20liquid%20solid%20profile%20measurement.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ump-ir.31315
record_format uketd_dc
spelling my-ump-ir.313152023-01-12T03:06:50Z 2 MHz electrical resistance tomography for static liquid solid profile measurement 2017-05 Yasmin, Abdul Wahab TK Electrical engineering. Electronics Nuclear engineering Tomography is a technique used to reconstruct cross-sectional image of a pipeline for flow monitoring applications. There are several types of tomography system such as X-ray tomography, ultrasonic tomography, and electrical resistance tomography (ERT). ERT has many advantages compared to other types of tomography such as low cost, robust and no radiation. Thus, it becomes particularly suitable for industrial applications. However, it has been observed that the conventional practice of ERT through invasive sensing technique has exposed the ERT metal sensor to corrosion and limited its application because of inaccurate measurement of the data. Consequently, non-invasive ERT has also been introduced in low frequency (in kHz) applied to the ERT system. The low frequency ERT makes use of the phase-sensitive demodulation (PSD) approach and is a complicated technique to implement. Hence, the goal of this research is to design and develop a non-invasive ERT system with a high frequency (2 MHz) source. A total impedance of coupling capacitances (between metal electrode and conductive medium) series with resistance (conductive medium) for each pair of electrodes was assumed in the research. Based on the mathematical equation of the total impedance, a real part that is the resistance (conductive medium) must be larger than an imaginary part (capacitances), so that it easily to detect the concentration profile of the conductive medium. Therefore, the minimum frequency to ensure the real part is bigger than the imaginary one is 2 MHz. Simultaneously, the independent and flexible sixteen ERT electrodes designed for the system make it easier to replace and troubleshoot any problems with the sensor. In addition, the system carried out an experimental two-phase static liquid–solid regime for a linear back-projection algorithm using online configuration, with MATLAB as a software platform. It was also able to detect and visualize the non homogenous system of the two-phase regime. Later, the reconstructed image was improved using a global threshold technique through offline configuration. The experiment results indicate that it could detect obstacles in a vertical pipe with minimum 12 mm in diameter and 4.5 cm in height, and above. 2017-05 Thesis http://umpir.ump.edu.my/id/eprint/31315/ http://umpir.ump.edu.my/id/eprint/31315/1/2%20mhz%20electrical%20resistance%20tomography%20for%20static%20liquid%20solid%20profile%20measurement.pdf pdf en public phd doctoral Universiti Teknologi Malaysia Faculty of Electrical Engineering Ruzairi, Abdul Rahim
institution Universiti Malaysia Pahang Al-Sultan Abdullah
collection UMPSA Institutional Repository
language English
advisor Ruzairi, Abdul Rahim
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Yasmin, Abdul Wahab
2 MHz electrical resistance tomography for static liquid solid profile measurement
description Tomography is a technique used to reconstruct cross-sectional image of a pipeline for flow monitoring applications. There are several types of tomography system such as X-ray tomography, ultrasonic tomography, and electrical resistance tomography (ERT). ERT has many advantages compared to other types of tomography such as low cost, robust and no radiation. Thus, it becomes particularly suitable for industrial applications. However, it has been observed that the conventional practice of ERT through invasive sensing technique has exposed the ERT metal sensor to corrosion and limited its application because of inaccurate measurement of the data. Consequently, non-invasive ERT has also been introduced in low frequency (in kHz) applied to the ERT system. The low frequency ERT makes use of the phase-sensitive demodulation (PSD) approach and is a complicated technique to implement. Hence, the goal of this research is to design and develop a non-invasive ERT system with a high frequency (2 MHz) source. A total impedance of coupling capacitances (between metal electrode and conductive medium) series with resistance (conductive medium) for each pair of electrodes was assumed in the research. Based on the mathematical equation of the total impedance, a real part that is the resistance (conductive medium) must be larger than an imaginary part (capacitances), so that it easily to detect the concentration profile of the conductive medium. Therefore, the minimum frequency to ensure the real part is bigger than the imaginary one is 2 MHz. Simultaneously, the independent and flexible sixteen ERT electrodes designed for the system make it easier to replace and troubleshoot any problems with the sensor. In addition, the system carried out an experimental two-phase static liquid–solid regime for a linear back-projection algorithm using online configuration, with MATLAB as a software platform. It was also able to detect and visualize the non homogenous system of the two-phase regime. Later, the reconstructed image was improved using a global threshold technique through offline configuration. The experiment results indicate that it could detect obstacles in a vertical pipe with minimum 12 mm in diameter and 4.5 cm in height, and above.
format Thesis
qualification_name Doctor of Philosophy (PhD.)
qualification_level Doctorate
author Yasmin, Abdul Wahab
author_facet Yasmin, Abdul Wahab
author_sort Yasmin, Abdul Wahab
title 2 MHz electrical resistance tomography for static liquid solid profile measurement
title_short 2 MHz electrical resistance tomography for static liquid solid profile measurement
title_full 2 MHz electrical resistance tomography for static liquid solid profile measurement
title_fullStr 2 MHz electrical resistance tomography for static liquid solid profile measurement
title_full_unstemmed 2 MHz electrical resistance tomography for static liquid solid profile measurement
title_sort 2 mhz electrical resistance tomography for static liquid solid profile measurement
granting_institution Universiti Teknologi Malaysia
granting_department Faculty of Electrical Engineering
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/31315/1/2%20mhz%20electrical%20resistance%20tomography%20for%20static%20liquid%20solid%20profile%20measurement.pdf
_version_ 1783732165059543040