Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control

The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustai...

Full description

Saved in:
Bibliographic Details
Main Author: Wan Nur Huda Aqilah, Alias
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/34630/1/PEMBANGUNAN%20MODEL%20KONSEPTUAL%20e-CAV%20SEBAGAI%20PENAMBAHBAIKAN.ir.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ump-ir.34630
record_format uketd_dc
spelling my-ump-ir.346302022-10-14T03:39:08Z Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control 2021-02 Wan Nur Huda Aqilah, Alias T Technology (General) TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method. 2021-02 Thesis http://umpir.ump.edu.my/id/eprint/34630/ http://umpir.ump.edu.my/id/eprint/34630/1/PEMBANGUNAN%20MODEL%20KONSEPTUAL%20e-CAV%20SEBAGAI%20PENAMBAHBAIKAN.ir.pdf pdf en public masters Universiti Malaysia Pahang Faculty of Electrical & Electronics Engineering Technology
institution Universiti Malaysia Pahang Al-Sultan Abdullah
collection UMPSA Institutional Repository
language English
topic T Technology (General)
T Technology (General)
T Technology (General)
spellingShingle T Technology (General)
T Technology (General)
T Technology (General)
Wan Nur Huda Aqilah, Alias
Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
description The advancement of technology and the increase in population have increased the demand for electrical supply as well. The drawbacks of electrical generating from nonrenewable energy to the environment have encouraged the researchers to produce clean and sustained power in vast quantities from sustainable energy. Recently, PV systems are frequently used owing to its light and easy-to-install characteristics. Although it was proven auspicious, faults can happen on the grid side of a grid-connected PV system, causing overshoot DC voltage and overcurrent. Thus, stressing the electrical component, lessening the system’s power quality and inverter’s trip. Therefore, many FRT strategies have been introduced to overcome these issues. This thesis proposed a new approach to alleviate this matter by controlling zero switching state of NPC inverter while injecting reactive current to the grid. First, the development of a two-stage grid-connected PV system was stated and the effects of grid faults were deliberated. Some conventional FRT strategies employed in the grid-connected PV system were studied. Furthermore, the efficiency of the scheme was verified by comparing it with a conventional method using DC chopper. The results showed the proposed method could lessen the overshoot DC voltage and injecting reactive current to the grid. Also, the results shown were similar to those of the conventional method.
format Thesis
qualification_level Master's degree
author Wan Nur Huda Aqilah, Alias
author_facet Wan Nur Huda Aqilah, Alias
author_sort Wan Nur Huda Aqilah, Alias
title Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
title_short Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
title_full Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
title_fullStr Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
title_full_unstemmed Performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
title_sort performance analysis on grid-connected pv system during grid faults with dc-link protection and decoupled current control
granting_institution Universiti Malaysia Pahang
granting_department Faculty of Electrical & Electronics Engineering Technology
publishDate 2021
url http://umpir.ump.edu.my/id/eprint/34630/1/PEMBANGUNAN%20MODEL%20KONSEPTUAL%20e-CAV%20SEBAGAI%20PENAMBAHBAIKAN.ir.pdf
_version_ 1783732199925743616