Study on an application of bioengineering by layer TIRF measurement

The nature inside bacterial cell has traditionally been viewed as an environment where intermolecular interactions are governed by isotropic diffusion. However, in latest studies, it is reported that the interactions are sub-diffusive. In order to have better understanding on this phenomenon, it is...

Full description

Saved in:
Bibliographic Details
Main Author: Syukran Hakim, Norazman
Format: Thesis
Language:English
Published: 2013
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9050/1/SYUKRAN%20HAKIM%20BIN%20NORAZMAN.PDF
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ump-ir.9050
record_format uketd_dc
spelling my-ump-ir.90502021-08-19T04:05:56Z Study on an application of bioengineering by layer TIRF measurement 2013-02 Syukran Hakim, Norazman TA Engineering (General). Civil engineering (General) The nature inside bacterial cell has traditionally been viewed as an environment where intermolecular interactions are governed by isotropic diffusion. However, in latest studies, it is reported that the interactions are sub-diffusive. In order to have better understanding on this phenomenon, it is necessary to conduct a 3-dimensional measurement of biological substance's high-speed motion at nano-scale. In recent years, measurement of biological substance has significantly advanced since the introduction of TI RFM (Total Internal Reflection Fluorescence Microscopy). TI RFM uses evanescent light to illuminate and capture images from samples located a few hundred nano-metersfrom the microscope glass plate. Originally, TIRFM can only be used to measure samples in 2-dimensional. However, a method to image samples in pseudo 3-dimensional, called layer TIRF has been developed. In this method, it is possible to calculate the pseudo z-coordinate by matching the decaying ratio of evanescent light to the particle's z-axis location. Up until now, only low-speed measurement has been made. In this work, a high speed measurement was achieved. First, calibration of static particles were conducted. Magnesium Fluoride (MgF 2 ) patterns with a width of 10[4m] and thickness of 100200 [nm] were fabricated onto a glass plate. Bio-nanoparticles were placed onto the plate and z-axis coordinate were calibrated. Then, 3-dimensional Brownian motion of the bionanoparticles near the glass wall were captured using a high speed EMCCD camera. A low pass filter algorithm was used to reduce noise in captured images. The diffusion coefficient of bionanoparticles were calculated and the result obtained was close to the theoretical values. 2013-02 Thesis http://umpir.ump.edu.my/id/eprint/9050/ http://umpir.ump.edu.my/id/eprint/9050/1/SYUKRAN%20HAKIM%20BIN%20NORAZMAN.PDF application/pdf en public masters Tokyo University of Science Department of Applied Electronics Satake Laboratory
institution Universiti Malaysia Pahang Al-Sultan Abdullah
collection UMPSA Institutional Repository
language English
topic TA Engineering (General)
Civil engineering (General)
spellingShingle TA Engineering (General)
Civil engineering (General)
Syukran Hakim, Norazman
Study on an application of bioengineering by layer TIRF measurement
description The nature inside bacterial cell has traditionally been viewed as an environment where intermolecular interactions are governed by isotropic diffusion. However, in latest studies, it is reported that the interactions are sub-diffusive. In order to have better understanding on this phenomenon, it is necessary to conduct a 3-dimensional measurement of biological substance's high-speed motion at nano-scale. In recent years, measurement of biological substance has significantly advanced since the introduction of TI RFM (Total Internal Reflection Fluorescence Microscopy). TI RFM uses evanescent light to illuminate and capture images from samples located a few hundred nano-metersfrom the microscope glass plate. Originally, TIRFM can only be used to measure samples in 2-dimensional. However, a method to image samples in pseudo 3-dimensional, called layer TIRF has been developed. In this method, it is possible to calculate the pseudo z-coordinate by matching the decaying ratio of evanescent light to the particle's z-axis location. Up until now, only low-speed measurement has been made. In this work, a high speed measurement was achieved. First, calibration of static particles were conducted. Magnesium Fluoride (MgF 2 ) patterns with a width of 10[4m] and thickness of 100200 [nm] were fabricated onto a glass plate. Bio-nanoparticles were placed onto the plate and z-axis coordinate were calibrated. Then, 3-dimensional Brownian motion of the bionanoparticles near the glass wall were captured using a high speed EMCCD camera. A low pass filter algorithm was used to reduce noise in captured images. The diffusion coefficient of bionanoparticles were calculated and the result obtained was close to the theoretical values.
format Thesis
qualification_level Master's degree
author Syukran Hakim, Norazman
author_facet Syukran Hakim, Norazman
author_sort Syukran Hakim, Norazman
title Study on an application of bioengineering by layer TIRF measurement
title_short Study on an application of bioengineering by layer TIRF measurement
title_full Study on an application of bioengineering by layer TIRF measurement
title_fullStr Study on an application of bioengineering by layer TIRF measurement
title_full_unstemmed Study on an application of bioengineering by layer TIRF measurement
title_sort study on an application of bioengineering by layer tirf measurement
granting_institution Tokyo University of Science
granting_department Department of Applied Electronics Satake Laboratory
publishDate 2013
url http://umpir.ump.edu.my/id/eprint/9050/1/SYUKRAN%20HAKIM%20BIN%20NORAZMAN.PDF
_version_ 1783731949951516672