A surface-based study on andrassy geothermal prospect for power generation

This surface-based geothermal study was conducted in the Andrassy geothermal prospect in Tawau and it consists of three parts. Firstly, the current state of geothermal activity was assessed through reconnaissance and geochemical study. Secondly, the ground surface thermal profile of the most prob...

Full description

Saved in:
Bibliographic Details
Main Author: Chong, Harry Lye Hin
Format: Thesis
Language:English
Published: 2001
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/19695/1/A%20surface-based%20study%20on%20andrassy.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ums-ep.19695
record_format uketd_dc
spelling my-ums-ep.196952018-04-02T06:16:48Z A surface-based study on andrassy geothermal prospect for power generation 2001 Chong, Harry Lye Hin TK Electrical engineering. Electronics Nuclear engineering This surface-based geothermal study was conducted in the Andrassy geothermal prospect in Tawau and it consists of three parts. Firstly, the current state of geothermal activity was assessed through reconnaissance and geochemical study. Secondly, the ground surface thermal profile of the most probable resource area was investigated via field measurements and satellite data analysis. Thirdly, the ambient environment of the most probable resource area was surveyed and its data were then applied to simple calculation models to foresee the potential environmental impacts in the absence of a binary geothermal power plant. Five new geothermal manifestations were discovered and another ten active manifestations were redocumented during this study. These manifestations were 43.3 - 78.2 °C in temperature and 6.01 - 7.12 in pH. They appeared to be NW aligned, suggesting structural control. The geothermometry results gave calculated reservoir temperature in the range of 180 - 238°C that warrant geothermal power generation. However, no ground surface thermal anomaly was detected in the most probable resource area and its vicinity; the ground surface temperature ranged from 26.6 - 33.0 °C. No significant on-going-operational environmental impact was foreseen. Based on the reconnaissance and geochemical study results, the current geothermal activity is concluded to be more active than it was in 1989 when it was assessed by Lim et. a/. (1991). Nonetheless, there is insufficient evidence to conclude that the resource is in the most probable resource area as claimed by PLN (1993), further geophysical study is required. The minor on-going-operational environmental impacts foreseen, however, do encourage the development of geothermal binary power plant in the Andrassy prospect. In addition, this study has foreseen some other options of geothermal development. 2001 Thesis https://eprints.ums.edu.my/id/eprint/19695/ https://eprints.ums.edu.my/id/eprint/19695/1/A%20surface-based%20study%20on%20andrassy.pdf text en public masters Universiti Malaysia Sabah Faculty of Science and Natural Resources
institution Universiti Malaysia Sabah
collection UMS Institutional Repository
language English
topic TK Electrical engineering
Electronics Nuclear engineering
spellingShingle TK Electrical engineering
Electronics Nuclear engineering
Chong, Harry Lye Hin
A surface-based study on andrassy geothermal prospect for power generation
description This surface-based geothermal study was conducted in the Andrassy geothermal prospect in Tawau and it consists of three parts. Firstly, the current state of geothermal activity was assessed through reconnaissance and geochemical study. Secondly, the ground surface thermal profile of the most probable resource area was investigated via field measurements and satellite data analysis. Thirdly, the ambient environment of the most probable resource area was surveyed and its data were then applied to simple calculation models to foresee the potential environmental impacts in the absence of a binary geothermal power plant. Five new geothermal manifestations were discovered and another ten active manifestations were redocumented during this study. These manifestations were 43.3 - 78.2 °C in temperature and 6.01 - 7.12 in pH. They appeared to be NW aligned, suggesting structural control. The geothermometry results gave calculated reservoir temperature in the range of 180 - 238°C that warrant geothermal power generation. However, no ground surface thermal anomaly was detected in the most probable resource area and its vicinity; the ground surface temperature ranged from 26.6 - 33.0 °C. No significant on-going-operational environmental impact was foreseen. Based on the reconnaissance and geochemical study results, the current geothermal activity is concluded to be more active than it was in 1989 when it was assessed by Lim et. a/. (1991). Nonetheless, there is insufficient evidence to conclude that the resource is in the most probable resource area as claimed by PLN (1993), further geophysical study is required. The minor on-going-operational environmental impacts foreseen, however, do encourage the development of geothermal binary power plant in the Andrassy prospect. In addition, this study has foreseen some other options of geothermal development.
format Thesis
qualification_level Master's degree
author Chong, Harry Lye Hin
author_facet Chong, Harry Lye Hin
author_sort Chong, Harry Lye Hin
title A surface-based study on andrassy geothermal prospect for power generation
title_short A surface-based study on andrassy geothermal prospect for power generation
title_full A surface-based study on andrassy geothermal prospect for power generation
title_fullStr A surface-based study on andrassy geothermal prospect for power generation
title_full_unstemmed A surface-based study on andrassy geothermal prospect for power generation
title_sort surface-based study on andrassy geothermal prospect for power generation
granting_institution Universiti Malaysia Sabah
granting_department Faculty of Science and Natural Resources
publishDate 2001
url https://eprints.ums.edu.my/id/eprint/19695/1/A%20surface-based%20study%20on%20andrassy.pdf
_version_ 1747836520924971008