Study of operating conditions on fabrication of a kaolin hollow fibre membrane

A high surface to volume ratio and harsh environments stability of a ceramic hollow fibre membrane attracts its current use. Currently, it is produced using expensive advanced ceramics (Al2O3, Ti2O, ZrO2 etc.). In this research, the inexpensive kaolin was proposed as hollow fibre membrane material....

Full description

Saved in:
Bibliographic Details
Main Author: Zykamilia Kamin
Format: Thesis
Language:English
English
Published: 2011
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/40573/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40573/2/FULLTEXT.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ums-ep.40573
record_format uketd_dc
spelling my-ums-ep.405732024-08-07T00:39:20Z Study of operating conditions on fabrication of a kaolin hollow fibre membrane 2011 Zykamilia Kamin TA401-492 Materials of engineering and construction. Mechanics of materials A high surface to volume ratio and harsh environments stability of a ceramic hollow fibre membrane attracts its current use. Currently, it is produced using expensive advanced ceramics (Al2O3, Ti2O, ZrO2 etc.). In this research, the inexpensive kaolin was proposed as hollow fibre membrane material. However, available spinning condition for hollow fibre membrane (HFM) preparation of the existing materials is not suitable for kaolin. Therefore this study reveals the fundamental knowledge to prepare kaolin HFM. Morphology study is important as an indicator for ceramic HFM applications either in separation or deposition of catalyst. In this study, various suspensions were prepared containing kaolin, polyethersulfone (PESf) and n-methyl-2-pyrrolidone (NMP) as ceramic powder, polymer binder and solvent respectively, spun at 0, 3 and 6 cm air gaps and later sintered between 1100 and 1600 °C. The results showed that suspensions viscosity between 1.280 x 103 and 3.310 x 105 cp were obtained. Fibres with regular cross-section were achieved at 3 and 6 cm air gaps. Subsequently, an increased in spinneret dimension required for a higher air gap to form a continuously nascent fibre. By scanning electron microscopy, asymmetric fibres were obtained; with outer finger-like voids and inner finger-like voids dominated the fibre cross-section at a low viscosity and a low air gap respectively. At increasing viscosity and air gap heights, the voids growth were inhibited by their respective contrast voids, due to the increased of kaolin particles amount at distributed particle size coupled with the gravitational effect and a retention time for particles orientation. Sponge region were seen to dominate the fibre cross-section in the most viscous (ratio of kaolin/PESf 3.5 (S6)) fibres spun at 6 cm (the longest air gap). After sintering, fibres asymmetric structures were retained; however, the S6 fibre outer finger-like voids sintered at 1600 °C were eliminated. The kaolin fibre morphology showed versatile structures depending on the process condition used. 2011 Thesis https://eprints.ums.edu.my/id/eprint/40573/ https://eprints.ums.edu.my/id/eprint/40573/1/24%20PAGES.pdf text en public https://eprints.ums.edu.my/id/eprint/40573/2/FULLTEXT.pdf text en validuser masters Universiti Malaysia Sabah Sekolah Kejuruteraan dan Teknologi Maklumat
institution Universiti Malaysia Sabah
collection UMS Institutional Repository
language English
English
topic TA401-492 Materials of engineering and construction
Mechanics of materials
spellingShingle TA401-492 Materials of engineering and construction
Mechanics of materials
Zykamilia Kamin
Study of operating conditions on fabrication of a kaolin hollow fibre membrane
description A high surface to volume ratio and harsh environments stability of a ceramic hollow fibre membrane attracts its current use. Currently, it is produced using expensive advanced ceramics (Al2O3, Ti2O, ZrO2 etc.). In this research, the inexpensive kaolin was proposed as hollow fibre membrane material. However, available spinning condition for hollow fibre membrane (HFM) preparation of the existing materials is not suitable for kaolin. Therefore this study reveals the fundamental knowledge to prepare kaolin HFM. Morphology study is important as an indicator for ceramic HFM applications either in separation or deposition of catalyst. In this study, various suspensions were prepared containing kaolin, polyethersulfone (PESf) and n-methyl-2-pyrrolidone (NMP) as ceramic powder, polymer binder and solvent respectively, spun at 0, 3 and 6 cm air gaps and later sintered between 1100 and 1600 °C. The results showed that suspensions viscosity between 1.280 x 103 and 3.310 x 105 cp were obtained. Fibres with regular cross-section were achieved at 3 and 6 cm air gaps. Subsequently, an increased in spinneret dimension required for a higher air gap to form a continuously nascent fibre. By scanning electron microscopy, asymmetric fibres were obtained; with outer finger-like voids and inner finger-like voids dominated the fibre cross-section at a low viscosity and a low air gap respectively. At increasing viscosity and air gap heights, the voids growth were inhibited by their respective contrast voids, due to the increased of kaolin particles amount at distributed particle size coupled with the gravitational effect and a retention time for particles orientation. Sponge region were seen to dominate the fibre cross-section in the most viscous (ratio of kaolin/PESf 3.5 (S6)) fibres spun at 6 cm (the longest air gap). After sintering, fibres asymmetric structures were retained; however, the S6 fibre outer finger-like voids sintered at 1600 °C were eliminated. The kaolin fibre morphology showed versatile structures depending on the process condition used.
format Thesis
qualification_level Master's degree
author Zykamilia Kamin
author_facet Zykamilia Kamin
author_sort Zykamilia Kamin
title Study of operating conditions on fabrication of a kaolin hollow fibre membrane
title_short Study of operating conditions on fabrication of a kaolin hollow fibre membrane
title_full Study of operating conditions on fabrication of a kaolin hollow fibre membrane
title_fullStr Study of operating conditions on fabrication of a kaolin hollow fibre membrane
title_full_unstemmed Study of operating conditions on fabrication of a kaolin hollow fibre membrane
title_sort study of operating conditions on fabrication of a kaolin hollow fibre membrane
granting_institution Universiti Malaysia Sabah
granting_department Sekolah Kejuruteraan dan Teknologi Maklumat
publishDate 2011
url https://eprints.ums.edu.my/id/eprint/40573/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40573/2/FULLTEXT.pdf
_version_ 1811770533829672960