Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique

Eddy Current Testing (ECT) technique is one of the Non-Destructive Testing (NDT) methods that is sensitive to the unintended signal such as the lift-off (LO) effect. For ECT technique, LO effect is one of the constraints due to the weakened detection that affected the output of the signals. This pre...

Full description

Saved in:
Bibliographic Details
Main Author: Salmia Santa
Format: Thesis
Language:English
English
Published: 2020
Subjects:
Online Access:https://eprints.ums.edu.my/id/eprint/40709/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40709/2/FULLTEXT.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-ums-ep.40709
record_format uketd_dc
spelling my-ums-ep.407092024-10-03T00:50:20Z Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique 2020 Salmia Santa TA401-492 Materials of engineering and construction. Mechanics of materials Eddy Current Testing (ECT) technique is one of the Non-Destructive Testing (NDT) methods that is sensitive to the unintended signal such as the lift-off (LO) effect. For ECT technique, LO effect is one of the constraints due to the weakened detection that affected the output of the signals. This presented research aims to develop a coil probe that generates eddy current signals by using an ECT technique to determine the optimum distance of LO height for three different chosen materials (e.g., copper, brass, and magnesium alloy) of three (3) different thickness which is 1.5 mm, 3.0 mm and 5.0 mm each. The output voltage of the defects signal of the tested materials can be determined from the optimum distance of LO height of the ECT technique. The coil probe used consists of an exciter-receiver coil, where 5.25 MHz is the optimal frequency. This frequency then generates the signal of the ECT technique. This technique was set up using a 50 ohms function generator and an established amplifier to boost up the output signals. The acquired optimum distance LO height for this research is approximately 2 mm. The findings from this established technique indicate that the determined LO height can be determined from the output voltage signal of the defects as well as to detect the thicknesses. The output voltage signal from the ECT technique was analysed and compared. As conclusion, the output voltage signals slightly increased for larger material defects and subsequently decreased with greater thickness detection. Hence, the LO height parameters of the ECT technique in this research can detect defect appropriately. 2020 Thesis https://eprints.ums.edu.my/id/eprint/40709/ https://eprints.ums.edu.my/id/eprint/40709/1/24%20PAGES.pdf text en public https://eprints.ums.edu.my/id/eprint/40709/2/FULLTEXT.pdf text en validuser masters Universiti Malaysia Sabah Faculty of Science and Natural Resources
institution Universiti Malaysia Sabah
collection UMS Institutional Repository
language English
English
topic TA401-492 Materials of engineering and construction
Mechanics of materials
spellingShingle TA401-492 Materials of engineering and construction
Mechanics of materials
Salmia Santa
Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
description Eddy Current Testing (ECT) technique is one of the Non-Destructive Testing (NDT) methods that is sensitive to the unintended signal such as the lift-off (LO) effect. For ECT technique, LO effect is one of the constraints due to the weakened detection that affected the output of the signals. This presented research aims to develop a coil probe that generates eddy current signals by using an ECT technique to determine the optimum distance of LO height for three different chosen materials (e.g., copper, brass, and magnesium alloy) of three (3) different thickness which is 1.5 mm, 3.0 mm and 5.0 mm each. The output voltage of the defects signal of the tested materials can be determined from the optimum distance of LO height of the ECT technique. The coil probe used consists of an exciter-receiver coil, where 5.25 MHz is the optimal frequency. This frequency then generates the signal of the ECT technique. This technique was set up using a 50 ohms function generator and an established amplifier to boost up the output signals. The acquired optimum distance LO height for this research is approximately 2 mm. The findings from this established technique indicate that the determined LO height can be determined from the output voltage signal of the defects as well as to detect the thicknesses. The output voltage signal from the ECT technique was analysed and compared. As conclusion, the output voltage signals slightly increased for larger material defects and subsequently decreased with greater thickness detection. Hence, the LO height parameters of the ECT technique in this research can detect defect appropriately.
format Thesis
qualification_level Master's degree
author Salmia Santa
author_facet Salmia Santa
author_sort Salmia Santa
title Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
title_short Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
title_full Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
title_fullStr Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
title_full_unstemmed Optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
title_sort optimum distance of lift-off height to detect defect on testing materials using eddy current testing technique
granting_institution Universiti Malaysia Sabah
granting_department Faculty of Science and Natural Resources
publishDate 2020
url https://eprints.ums.edu.my/id/eprint/40709/1/24%20PAGES.pdf
https://eprints.ums.edu.my/id/eprint/40709/2/FULLTEXT.pdf
_version_ 1818611369074753536