Design and development of single phase AC induction motor using copper rotor bars
In this thesis, the single phase AC induction motor have been investigated and analyzed in terms of the induction motor parameter, efficiency, power factor and loss segregation of different rotor bar material. A copper rotor bar is fabricated and compared with the existing aluminium rotor bar thr...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Subjects: | |
Online Access: | http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/20812/1/Full%20text.pdf http://dspace.unimap.edu.my:80/xmlui/bitstream/123456789/20812/2/p.1-24.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this thesis, the single phase AC induction motor have been investigated and analyzed in terms
of the induction motor parameter, efficiency, power factor and loss segregation of different rotor
bar material. A copper rotor bar is fabricated and compared with the existing aluminium rotor
bar through out this project. First aspect of comparison is done with software simulation using
Opera 2D between aluminium rotor bar and copper rotor bar for the same 1.5HP stator slot
design and winding configuration. The Opera 2D is compared in range of power loss, magnetic
flux density, torque vs. speed, torque vs. slip, power loss vs. speed and power loss vs. slip. The
second aspect is the hardware comparison between the fabricated copper rotor bars with the
existing aluminium rotor bar. In this part, the copper rotor bar and aluminium rotor bar are
tested using no load, blocked rotor, and DC resistance test to achive the difference of efficiency,
losses and power factor improvement. From the overall experiment of software and hardware,
results shows that copper rotor bar does increase the efficiency and power factor to 1.07 % and
reduce losses to 11 watts compare to aluminium rotor bar. An economical aspect is presented to
show the amount of energy and money that can be saved from replacing the aluminium rotor bar
with a copper rotor bar. As for the annual energy saving (AES) and total cost saving (TCS), the
copper rotor manage to save 124.51kWh per year and utility billing by RM41.76 per year per
motor. Finally a rough estimation of 100,000 pieces induction motor that have been replaced
with the copper rotor bars is assumed and shows that it will save approximately RM4.2 million. |
---|