Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site

This project aimed to harness mechanical energy of exhaust cooling water running continuously in a discharge weir of a base load power plant. However, three major problems were encountered: the site is an operating artificial site, the exhaust cooling water is heated sea water, and the custom syste...

Full description

Saved in:
Bibliographic Details
Main Author: Tian, Chuan Min
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://ir.unimas.my/id/eprint/21009/1/Chuan.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-unimas-ir.21009
record_format uketd_dc
spelling my-unimas-ir.210092023-08-23T07:02:42Z Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site 2016 Tian, Chuan Min TJ Mechanical engineering and machinery This project aimed to harness mechanical energy of exhaust cooling water running continuously in a discharge weir of a base load power plant. However, three major problems were encountered: the site is an operating artificial site, the exhaust cooling water is heated sea water, and the custom system is required to be flexible. These problems necessitate a custom design. This custom system was developed from scratch; it was designed, fabricated and installed very differently compared to other micro hydros. As a novel system, it was evaluated in two aspects – through economic and performance study. Due to safety reasons, the system underwent proof run for a three-month period, without involving extensive on-site experimentation. Therefore, physical and mathematical modeling, as well as parametric study, were carried out to complement the evaluation. Results obtained showed that the hybrid turbine was indeed a reaction turbine, the custom system was capable of reaching 45% efficiency, and its payback period was estimated as 4.23 years. All in all, the system is feasible for the sensitive site application. unimas 2016 Thesis http://ir.unimas.my/id/eprint/21009/ http://ir.unimas.my/id/eprint/21009/1/Chuan.pdf text en validuser masters UNIMAS
institution Universiti Malaysia Sarawak
collection UNIMAS Institutional Repository
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Tian, Chuan Min
Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
description This project aimed to harness mechanical energy of exhaust cooling water running continuously in a discharge weir of a base load power plant. However, three major problems were encountered: the site is an operating artificial site, the exhaust cooling water is heated sea water, and the custom system is required to be flexible. These problems necessitate a custom design. This custom system was developed from scratch; it was designed, fabricated and installed very differently compared to other micro hydros. As a novel system, it was evaluated in two aspects – through economic and performance study. Due to safety reasons, the system underwent proof run for a three-month period, without involving extensive on-site experimentation. Therefore, physical and mathematical modeling, as well as parametric study, were carried out to complement the evaluation. Results obtained showed that the hybrid turbine was indeed a reaction turbine, the custom system was capable of reaching 45% efficiency, and its payback period was estimated as 4.23 years. All in all, the system is feasible for the sensitive site application.
format Thesis
qualification_level Master's degree
author Tian, Chuan Min
author_facet Tian, Chuan Min
author_sort Tian, Chuan Min
title Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
title_short Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
title_full Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
title_fullStr Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
title_full_unstemmed Design, Develop And Techno-Economical Study of a Run-of-the-Weir Micro Hydro System for a Sensitive Site
title_sort design, develop and techno-economical study of a run-of-the-weir micro hydro system for a sensitive site
granting_institution UNIMAS
publishDate 2016
url http://ir.unimas.my/id/eprint/21009/1/Chuan.pdf
_version_ 1783728219637153792