Optimization on radiation dose and image quality in paediatric computed tomography examination

Computed tomography (CT) scan examinations have been acknowledged for its high dose exposure contribution. This is troublesome for paediatric as they are susceptibility to radiation and receives higher probability of radiation - induced cancer risk. Lowering the radiation dose while maintaining pati...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad, Nor Azura
Format: Thesis
Language:English
Published: 2021
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/104199/1/FS%202022%2034%20IR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.104199
record_format uketd_dc
spelling my-upm-ir.1041992023-08-07T07:26:26Z Optimization on radiation dose and image quality in paediatric computed tomography examination 2021-09 Muhammad, Nor Azura Computed tomography (CT) scan examinations have been acknowledged for its high dose exposure contribution. This is troublesome for paediatric as they are susceptibility to radiation and receives higher probability of radiation - induced cancer risk. Lowering the radiation dose while maintaining patient diagnostic value is a vital feature of all dose management practices. Henceforth, the first phase of this study is to establish the local Diagnostic Reference Levels (DRLs) for paediatric CT examination with consideration of the noise index. This retrospective study was approved by Medical Research Ethics Committee (MREC) of University of Malaya Medical Center (approval no: MREC id no 2018920-6690). One thousand one hundred and ninety-two (1192) paediatric patients underwent CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were recorded. For each group, data such as scanning acquisition parameters and dose information, volume weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were evaluated. The CT dose values between all age groups have differed significantly with p-value = 0.0001. There was a significant variation in doses and noise intensity among children of different ages. The second phase of this study involves adoption of ICRP Publication 103 report and Biological Effects of Ionizing Radiation (BEIR) VII report to determine the radiation-induced cancer risk among subjects. Notably, the highest incidence lifetime attributable risk (LAR) of liver cancer is found in the age group (10-15) with 5.9 out of 100,000 and 2.5 out of 100,000 respectively. The highest cancer risk was in the liver based on the ICRP 103 recommendations for both genders in age group of (1 - < 5) were 3.6 and 1.5 per 100,000 procedures in male and female respectively. The final phase of this study observed the impact of dose in radiosensitive organ and its influence towards image quality in CT Chest-Abdomen-Pelvis (CAP) examination after applying CT optimization process. The organ doses were evaluated by using a 1-year-old anthropomorphic phantom with a thermoluminescence dosimeter (TLD) as a passive dosimeter. In a whole, nine CT protocols were applied for optimization process and the image quality was evaluated by determine the signal to noise ratio (SNR) and contrast to noise ratio (CNR) of phantom images. Notably, the optimization process indicates a potential reduction in a dose up to 20 % to 50 % along with reducing tube voltage, tube current and with increasing slice collimation without compromising the diagnostic value. By turning off the Automatic Tube Current Modulation (ATCM) feature increases the radiation absorbed dose by 80%. Hence, regular CT dose monitoring and optimization procedures will reduce the probability of radiation-induced cancer risk and provide safer imaging practices. Radiation - Dosage Pediatric tomography Tomography - Image quality 2021-09 Thesis http://psasir.upm.edu.my/id/eprint/104199/ http://psasir.upm.edu.my/id/eprint/104199/1/FS%202022%2034%20IR.pdf text en public doctoral Universiti Putra Malaysia Radiation - Dosage Pediatric tomography Tomography - Image quality Abdul Karim, Muhammad Khalis
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
advisor Abdul Karim, Muhammad Khalis
topic Radiation - Dosage
Pediatric tomography
Tomography - Image quality
spellingShingle Radiation - Dosage
Pediatric tomography
Tomography - Image quality
Muhammad, Nor Azura
Optimization on radiation dose and image quality in paediatric computed tomography examination
description Computed tomography (CT) scan examinations have been acknowledged for its high dose exposure contribution. This is troublesome for paediatric as they are susceptibility to radiation and receives higher probability of radiation - induced cancer risk. Lowering the radiation dose while maintaining patient diagnostic value is a vital feature of all dose management practices. Henceforth, the first phase of this study is to establish the local Diagnostic Reference Levels (DRLs) for paediatric CT examination with consideration of the noise index. This retrospective study was approved by Medical Research Ethics Committee (MREC) of University of Malaya Medical Center (approval no: MREC id no 2018920-6690). One thousand one hundred and ninety-two (1192) paediatric patients underwent CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were recorded. For each group, data such as scanning acquisition parameters and dose information, volume weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were evaluated. The CT dose values between all age groups have differed significantly with p-value = 0.0001. There was a significant variation in doses and noise intensity among children of different ages. The second phase of this study involves adoption of ICRP Publication 103 report and Biological Effects of Ionizing Radiation (BEIR) VII report to determine the radiation-induced cancer risk among subjects. Notably, the highest incidence lifetime attributable risk (LAR) of liver cancer is found in the age group (10-15) with 5.9 out of 100,000 and 2.5 out of 100,000 respectively. The highest cancer risk was in the liver based on the ICRP 103 recommendations for both genders in age group of (1 - < 5) were 3.6 and 1.5 per 100,000 procedures in male and female respectively. The final phase of this study observed the impact of dose in radiosensitive organ and its influence towards image quality in CT Chest-Abdomen-Pelvis (CAP) examination after applying CT optimization process. The organ doses were evaluated by using a 1-year-old anthropomorphic phantom with a thermoluminescence dosimeter (TLD) as a passive dosimeter. In a whole, nine CT protocols were applied for optimization process and the image quality was evaluated by determine the signal to noise ratio (SNR) and contrast to noise ratio (CNR) of phantom images. Notably, the optimization process indicates a potential reduction in a dose up to 20 % to 50 % along with reducing tube voltage, tube current and with increasing slice collimation without compromising the diagnostic value. By turning off the Automatic Tube Current Modulation (ATCM) feature increases the radiation absorbed dose by 80%. Hence, regular CT dose monitoring and optimization procedures will reduce the probability of radiation-induced cancer risk and provide safer imaging practices.
format Thesis
qualification_level Doctorate
author Muhammad, Nor Azura
author_facet Muhammad, Nor Azura
author_sort Muhammad, Nor Azura
title Optimization on radiation dose and image quality in paediatric computed tomography examination
title_short Optimization on radiation dose and image quality in paediatric computed tomography examination
title_full Optimization on radiation dose and image quality in paediatric computed tomography examination
title_fullStr Optimization on radiation dose and image quality in paediatric computed tomography examination
title_full_unstemmed Optimization on radiation dose and image quality in paediatric computed tomography examination
title_sort optimization on radiation dose and image quality in paediatric computed tomography examination
granting_institution Universiti Putra Malaysia
publishDate 2021
url http://psasir.upm.edu.my/id/eprint/104199/1/FS%202022%2034%20IR.pdf
_version_ 1776100417348829184