Evaluation of residential sprinkler system in the Klang Valley

Fire awareness in residential units m Malaysia remams low compared to developed countries. Fire safety awareness is not improved through campaigns not other methods, and as such, is expected to remain low. This study aims to gauge the level of fire safety awareness through a survey in the Klang Va...

Full description

Saved in:
Bibliographic Details
Main Author: Thin, Voon Tuck
Format: Thesis
Language:English
Published: 1999
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/105927/1/FK%201999%2044%20UPM%20IR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.105927
record_format uketd_dc
spelling my-upm-ir.1059272024-06-10T03:59:30Z Evaluation of residential sprinkler system in the Klang Valley 1999-11 Thin, Voon Tuck Fire awareness in residential units m Malaysia remams low compared to developed countries. Fire safety awareness is not improved through campaigns not other methods, and as such, is expected to remain low. This study aims to gauge the level of fire safety awareness through a survey in the Klang Valley. In addition, the main focus of study is on the effectiveness of residential sprinkler systems and how these systems can be implemented in Malaysia. A specific design will be effected for the HRC housing project undertaken by Universiti Putra Malaysia. The study has concluded that fire safety awareness in residential units m Malaysia. This is based on the incidences of smoke detector usage, sprinkler system usage and evacuation plans in the event of fires. Both smoke detector usage and sprinkler systems in residential units are proven to reduce the fatality rate when a fire does break out. As such, implementation of these systems can significantly improve the life safety from fire of Malaysian homes. Unfortunately, the costs of fire protection systems in Malaysia can be prohibitive, and potential cost savings from reduction m insurance premiums are unlikely to be able to offset the initial investment required. The design developed for the HRC houses to be built by Universiti Putra Malaysia can incorporate residential sprinklers and smoke detectors to improve fire safety. Realisation of the entire fire strategy and design concept is however not done yet, especially as to the siting of the water storage requirements. Fire sprinklers Fire prevention Fire extinction 1999-11 Thesis http://psasir.upm.edu.my/id/eprint/105927/ http://psasir.upm.edu.my/id/eprint/105927/1/FK%201999%2044%20UPM%20IR.pdf text en public masters Universiti Putra Malaysia Fire sprinklers Fire prevention Fire extinction Adam, Nor Mariah
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
advisor Adam, Nor Mariah
topic Fire sprinklers
Fire prevention
Fire extinction
spellingShingle Fire sprinklers
Fire prevention
Fire extinction
Thin, Voon Tuck
Evaluation of residential sprinkler system in the Klang Valley
description Fire awareness in residential units m Malaysia remams low compared to developed countries. Fire safety awareness is not improved through campaigns not other methods, and as such, is expected to remain low. This study aims to gauge the level of fire safety awareness through a survey in the Klang Valley. In addition, the main focus of study is on the effectiveness of residential sprinkler systems and how these systems can be implemented in Malaysia. A specific design will be effected for the HRC housing project undertaken by Universiti Putra Malaysia. The study has concluded that fire safety awareness in residential units m Malaysia. This is based on the incidences of smoke detector usage, sprinkler system usage and evacuation plans in the event of fires. Both smoke detector usage and sprinkler systems in residential units are proven to reduce the fatality rate when a fire does break out. As such, implementation of these systems can significantly improve the life safety from fire of Malaysian homes. Unfortunately, the costs of fire protection systems in Malaysia can be prohibitive, and potential cost savings from reduction m insurance premiums are unlikely to be able to offset the initial investment required. The design developed for the HRC houses to be built by Universiti Putra Malaysia can incorporate residential sprinklers and smoke detectors to improve fire safety. Realisation of the entire fire strategy and design concept is however not done yet, especially as to the siting of the water storage requirements.
format Thesis
qualification_level Master's degree
author Thin, Voon Tuck
author_facet Thin, Voon Tuck
author_sort Thin, Voon Tuck
title Evaluation of residential sprinkler system in the Klang Valley
title_short Evaluation of residential sprinkler system in the Klang Valley
title_full Evaluation of residential sprinkler system in the Klang Valley
title_fullStr Evaluation of residential sprinkler system in the Klang Valley
title_full_unstemmed Evaluation of residential sprinkler system in the Klang Valley
title_sort evaluation of residential sprinkler system in the klang valley
granting_institution Universiti Putra Malaysia
publishDate 1999
url http://psasir.upm.edu.my/id/eprint/105927/1/FK%201999%2044%20UPM%20IR.pdf
_version_ 1804888724870266880