Microwave-Based Technique For Glucose Detection

Glucose biosensor is generally based on reaction between glucose and enzyme glucose oxidase (GOD) that produces gluconic acid and hydrogen peroxide. The gluconic acid is a conducting medium while hydrogen peroxide is a polar molecule. This work discovers the changes of dielectric properties due...

Full description

Saved in:
Bibliographic Details
Main Author: Md Salim, Nora Salina
Format: Thesis
Language:English
English
Published: 2010
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/12430/1/FS_2010_12A.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.12430
record_format uketd_dc
spelling my-upm-ir.124302013-10-29T04:32:50Z Microwave-Based Technique For Glucose Detection 2010-04 Md Salim, Nora Salina Glucose biosensor is generally based on reaction between glucose and enzyme glucose oxidase (GOD) that produces gluconic acid and hydrogen peroxide. The gluconic acid is a conducting medium while hydrogen peroxide is a polar molecule. This work discovers the changes of dielectric properties due to conductive loss below 4 GHz and dipole orientation of above 4 GHz of this reaction. The difference between the dielectric properties of an enzyme and glucose-enzyme reaction can be related to the glucose concentration in the sample. The dielectric properties of glucose solutions, enzyme GOD and glucose-enzyme reaction were measured using the Open Ended Coaxial Probe with frequency range from 200 MHz to 20 GHz at room temperature (25 'C). Two types of juice are used in this study; blackcurrant juice and lychee juice. The actual glucose content in juice samples were analyzed using High Performance Liquid Chromatography method. This technique has also been applied using the microstrip sensor for measuring glucose concentration in glucose solution, blackcurrant juice and lychee juice. The result shows that the highest sensitivity for the differences in dielectric changes with glucose concentrations due to the effect of ionic conductivity and dipole orientation were found at 0.99 GHz and 16.44 GHz respectively. The changes in dielectric loss are preferable for derivation of glucose concentration. In this proposed technique, the detection limit of glucose concentration is as low as 0.01 M (0.20 g/100 ml) with optimum ratio of 1:3 for an enzyme and glucose. Lychee juice has a higher dielectric loss difference for both frequencies followed by blackcurrant juice and glucose solution due to the contribution of free ions in the juice. The sensitivity of attenuation measurement using microstrip sensor is dependent on the dielectric loss of materials. The sensitivity of measurement about 0.002 dB/ (mg/ml) at 0.99 GHz and 0.004 dB/ (mg/ml) at 16.44 GHz which are comparable to the current microwave techniques. This technique gives benefit to the future development of microwave biosensor by which both ionic conductivity and dipole effects are occurred simultaneously. Glucose Glucose tolerance tests Microwaves 2010-04 Thesis http://psasir.upm.edu.my/id/eprint/12430/ http://psasir.upm.edu.my/id/eprint/12430/1/FS_2010_12A.pdf application/pdf en public masters Universiti Putra Malaysia Glucose Glucose tolerance tests Microwaves Faculty Of Science English
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
English
topic Glucose
Glucose tolerance tests
Microwaves
spellingShingle Glucose
Glucose tolerance tests
Microwaves
Md Salim, Nora Salina
Microwave-Based Technique For Glucose Detection
description Glucose biosensor is generally based on reaction between glucose and enzyme glucose oxidase (GOD) that produces gluconic acid and hydrogen peroxide. The gluconic acid is a conducting medium while hydrogen peroxide is a polar molecule. This work discovers the changes of dielectric properties due to conductive loss below 4 GHz and dipole orientation of above 4 GHz of this reaction. The difference between the dielectric properties of an enzyme and glucose-enzyme reaction can be related to the glucose concentration in the sample. The dielectric properties of glucose solutions, enzyme GOD and glucose-enzyme reaction were measured using the Open Ended Coaxial Probe with frequency range from 200 MHz to 20 GHz at room temperature (25 'C). Two types of juice are used in this study; blackcurrant juice and lychee juice. The actual glucose content in juice samples were analyzed using High Performance Liquid Chromatography method. This technique has also been applied using the microstrip sensor for measuring glucose concentration in glucose solution, blackcurrant juice and lychee juice. The result shows that the highest sensitivity for the differences in dielectric changes with glucose concentrations due to the effect of ionic conductivity and dipole orientation were found at 0.99 GHz and 16.44 GHz respectively. The changes in dielectric loss are preferable for derivation of glucose concentration. In this proposed technique, the detection limit of glucose concentration is as low as 0.01 M (0.20 g/100 ml) with optimum ratio of 1:3 for an enzyme and glucose. Lychee juice has a higher dielectric loss difference for both frequencies followed by blackcurrant juice and glucose solution due to the contribution of free ions in the juice. The sensitivity of attenuation measurement using microstrip sensor is dependent on the dielectric loss of materials. The sensitivity of measurement about 0.002 dB/ (mg/ml) at 0.99 GHz and 0.004 dB/ (mg/ml) at 16.44 GHz which are comparable to the current microwave techniques. This technique gives benefit to the future development of microwave biosensor by which both ionic conductivity and dipole effects are occurred simultaneously.
format Thesis
qualification_level Master's degree
author Md Salim, Nora Salina
author_facet Md Salim, Nora Salina
author_sort Md Salim, Nora Salina
title Microwave-Based Technique For Glucose Detection
title_short Microwave-Based Technique For Glucose Detection
title_full Microwave-Based Technique For Glucose Detection
title_fullStr Microwave-Based Technique For Glucose Detection
title_full_unstemmed Microwave-Based Technique For Glucose Detection
title_sort microwave-based technique for glucose detection
granting_institution Universiti Putra Malaysia
granting_department Faculty Of Science
publishDate 2010
url http://psasir.upm.edu.my/id/eprint/12430/1/FS_2010_12A.pdf
_version_ 1747811364503552000