Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode

A biosensor for simultaneous detection of Cd(II) and Hg(II) was developed by using MWCNT/peptides modified Au electrode using cyclic voltammetry (CV). It was observed that the MWCNT/peptide modified gold electrode has significant superior analytical performance in determination of Cd(II) and Hg(II)...

Full description

Saved in:
Bibliographic Details
Main Author: Abdul Rahman, Nadiah
Format: Thesis
Language:English
English
Published: 2011
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/19621/1/FS_2011_32.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.19621
record_format uketd_dc
spelling my-upm-ir.196212014-04-16T08:58:22Z Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode 2011-05 Abdul Rahman, Nadiah A biosensor for simultaneous detection of Cd(II) and Hg(II) was developed by using MWCNT/peptides modified Au electrode using cyclic voltammetry (CV). It was observed that the MWCNT/peptide modified gold electrode has significant superior analytical performance in determination of Cd(II) and Hg(II) compared to the unmodified gold electrode. The gold electrode surfaces are modified with peptides that were synthesized by self assembly of cysteine monomers in the presence of diphenylphosphoryl azide (DPPA). This self assembly approach leads to rapid access of cyclic dimer and linear tripeptide of cysteine. The yielded peptides together with the MWCNT are attached to the Au electrode for further characterization and optimization with CV. The experimental conditions such as pH, supporting electrolyte, reproducibility and scan rates of the modified Au electrode were optimized. Modification of peptide and MWCNT on the Au electrode surface has increased the sensitivity and selectivity of the electrochemical sensor for simultaneous determination of Cd(II) and Hg(II) ion. The reproducibility of the electrochemical sensor was good with relative standard deviation (R.S.D) value of 2.52%. The linear response for Cd(II)( in presence of borate buffer at pH 3) was obtained in the range of 0.1 ppm to 50.5 ppm whereas for Hg(II)( in presence of acetate buffer at pH 2) the linear response was obtained in the range of 0.1 ppm to 50.0 ppm. The slope value of log Ip versus log v is 0.61-0.85 demonstrate that the modified Au electrode undergoes diffusion-adsorption controlled process. The sensitivity expressed as the slope of linear region of calibration curve was 6 x 10-6 A/ppm in borate buffer (pH 3) and 8 x 10-7 A/ppm in acetate buffer (pH 2). The limit of detection (L.O.D) for Cd(II) is 2.75 x 10-8 M whereas the limit of detection for Hg(II) is 9.07 x 10-10 M. The developed electrochemical sensors were applied in analysis of electroplating and wood industrial waste water for simultaneous determination of toxic metal Cd(II) and Hg(II). The results of the waste water sample analysis based on the developed method showed a comparable result with the ICP-OES method. Biosensors Peptides Electrodes 2011-05 Thesis http://psasir.upm.edu.my/id/eprint/19621/ http://psasir.upm.edu.my/id/eprint/19621/1/FS_2011_32.pdf application/pdf en public masters Universiti Putra Malaysia Biosensors Peptides Electrodes Faculty of Science English
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
English
topic Biosensors
Peptides
Electrodes
spellingShingle Biosensors
Peptides
Electrodes
Abdul Rahman, Nadiah
Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
description A biosensor for simultaneous detection of Cd(II) and Hg(II) was developed by using MWCNT/peptides modified Au electrode using cyclic voltammetry (CV). It was observed that the MWCNT/peptide modified gold electrode has significant superior analytical performance in determination of Cd(II) and Hg(II) compared to the unmodified gold electrode. The gold electrode surfaces are modified with peptides that were synthesized by self assembly of cysteine monomers in the presence of diphenylphosphoryl azide (DPPA). This self assembly approach leads to rapid access of cyclic dimer and linear tripeptide of cysteine. The yielded peptides together with the MWCNT are attached to the Au electrode for further characterization and optimization with CV. The experimental conditions such as pH, supporting electrolyte, reproducibility and scan rates of the modified Au electrode were optimized. Modification of peptide and MWCNT on the Au electrode surface has increased the sensitivity and selectivity of the electrochemical sensor for simultaneous determination of Cd(II) and Hg(II) ion. The reproducibility of the electrochemical sensor was good with relative standard deviation (R.S.D) value of 2.52%. The linear response for Cd(II)( in presence of borate buffer at pH 3) was obtained in the range of 0.1 ppm to 50.5 ppm whereas for Hg(II)( in presence of acetate buffer at pH 2) the linear response was obtained in the range of 0.1 ppm to 50.0 ppm. The slope value of log Ip versus log v is 0.61-0.85 demonstrate that the modified Au electrode undergoes diffusion-adsorption controlled process. The sensitivity expressed as the slope of linear region of calibration curve was 6 x 10-6 A/ppm in borate buffer (pH 3) and 8 x 10-7 A/ppm in acetate buffer (pH 2). The limit of detection (L.O.D) for Cd(II) is 2.75 x 10-8 M whereas the limit of detection for Hg(II) is 9.07 x 10-10 M. The developed electrochemical sensors were applied in analysis of electroplating and wood industrial waste water for simultaneous determination of toxic metal Cd(II) and Hg(II). The results of the waste water sample analysis based on the developed method showed a comparable result with the ICP-OES method.
format Thesis
qualification_level Master's degree
author Abdul Rahman, Nadiah
author_facet Abdul Rahman, Nadiah
author_sort Abdul Rahman, Nadiah
title Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
title_short Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
title_full Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
title_fullStr Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
title_full_unstemmed Development of Biosensor for Determination of Cd(11) and Hg(11) Ion by Exploiting MWCNT/Peptide Nanohybrid Modified Au Electrode
title_sort development of biosensor for determination of cd(11) and hg(11) ion by exploiting mwcnt/peptide nanohybrid modified au electrode
granting_institution Universiti Putra Malaysia
granting_department Faculty of Science
publishDate 2011
url http://psasir.upm.edu.my/id/eprint/19621/1/FS_2011_32.pdf
_version_ 1747811426578202624