Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition

Lightning has been a major concern to the power system researchers as it may cause damage to the connected electrical equipment especially to the transmission and distribution line. One of the most event is backflashover that will cause lightning overvoltage. For that reason, one study has been carr...

Full description

Saved in:
Bibliographic Details
Main Author: Mohd Nawi, Zawati
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/52044/1/FK%202012%20139RR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.52044
record_format uketd_dc
spelling my-upm-ir.520442017-04-20T07:51:12Z Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition 2012-11 Mohd Nawi, Zawati Lightning has been a major concern to the power system researchers as it may cause damage to the connected electrical equipment especially to the transmission and distribution line. One of the most event is backflashover that will cause lightning overvoltage. For that reason, one study has been carried out where values of backflashover rate (BFR) on underbuilt transmission structure with characteristic of distribution line and provide the optimum placement of line arresters on phases at the tower of a distribution line to protect the line from overvoltage events. The purpose of this project is to model a 33 kV overhead distribution line for insulation coordination studies in which the investigation only focused on an underbuilt on transmission structure where the tower is also used for distribution system where the system voltage, characteristic and insulation strength are based on distribution system. A sample of worst performance underbuilt transmission structure in Peninsular Malaysia i.e. 33 kV Pantai Remis to Trong distribution line data was obtained from Tenaga Nasional Berhad (TNB). Power System Computer Aided Design, PSCAD software was used to model underbuilt distribution line components such as footing resistances, tower, insulator gap, arrester followed by doing the backflashover simulation and analysis. Besides that, the effects of line parameters such as ground resistance, soil resistivity, tower height, number of shield wire and placement line arrester on phases at the tower in lightning performance study were also investigated. Findings from backflashover analysis of Pantai Remis – Trong line using PSCAD imply that the values of backflashover rate (BFR) and also the best place to install line arrester are influenced by the values of line parameters. Right selection of line parameters may reduce BFR and the best place for installation line arrester, thus improve the distribution line performance. Findings of this research can be useful guideline towards high voltage transmission and distribution overhead line design and planning in Malaysia. Electric power distribution Transients (Electricity) Lightning 2012-11 Thesis http://psasir.upm.edu.my/id/eprint/52044/ http://psasir.upm.edu.my/id/eprint/52044/1/FK%202012%20139RR.pdf application/pdf en public masters Universiti Putra Malaysia Electric power distribution Transients (Electricity) Lightning
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
topic Electric power distribution
Transients (Electricity)
Lightning
spellingShingle Electric power distribution
Transients (Electricity)
Lightning
Mohd Nawi, Zawati
Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
description Lightning has been a major concern to the power system researchers as it may cause damage to the connected electrical equipment especially to the transmission and distribution line. One of the most event is backflashover that will cause lightning overvoltage. For that reason, one study has been carried out where values of backflashover rate (BFR) on underbuilt transmission structure with characteristic of distribution line and provide the optimum placement of line arresters on phases at the tower of a distribution line to protect the line from overvoltage events. The purpose of this project is to model a 33 kV overhead distribution line for insulation coordination studies in which the investigation only focused on an underbuilt on transmission structure where the tower is also used for distribution system where the system voltage, characteristic and insulation strength are based on distribution system. A sample of worst performance underbuilt transmission structure in Peninsular Malaysia i.e. 33 kV Pantai Remis to Trong distribution line data was obtained from Tenaga Nasional Berhad (TNB). Power System Computer Aided Design, PSCAD software was used to model underbuilt distribution line components such as footing resistances, tower, insulator gap, arrester followed by doing the backflashover simulation and analysis. Besides that, the effects of line parameters such as ground resistance, soil resistivity, tower height, number of shield wire and placement line arrester on phases at the tower in lightning performance study were also investigated. Findings from backflashover analysis of Pantai Remis – Trong line using PSCAD imply that the values of backflashover rate (BFR) and also the best place to install line arrester are influenced by the values of line parameters. Right selection of line parameters may reduce BFR and the best place for installation line arrester, thus improve the distribution line performance. Findings of this research can be useful guideline towards high voltage transmission and distribution overhead line design and planning in Malaysia.
format Thesis
qualification_level Master's degree
author Mohd Nawi, Zawati
author_facet Mohd Nawi, Zawati
author_sort Mohd Nawi, Zawati
title Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
title_short Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
title_full Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
title_fullStr Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
title_full_unstemmed Backflashover rate of underbuilt 33 kV distribution overhead line under lightning condition
title_sort backflashover rate of underbuilt 33 kv distribution overhead line under lightning condition
granting_institution Universiti Putra Malaysia
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/52044/1/FK%202012%20139RR.pdf
_version_ 1747812084359364608