Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor

Histamine levels have been suggested as a rapid fish spoilage indicator. Therefore, histamine biosensors based on immobilization of diamine oxidase (DAO) in photocurable poly (2-hydroxyethyl methacrylate) (photoHEMA) film was developed. Histamine was oxidized by immobilized DAO at 0.35 volt on the s...

Full description

Saved in:
Bibliographic Details
Main Author: Ching, Mai Keow
Format: Thesis
Language:English
English
Published: 2006
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/5359/1/IB_2006_12.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.5359
record_format uketd_dc
spelling my-upm-ir.53592013-05-27T07:22:15Z Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor 2006 Ching, Mai Keow Histamine levels have been suggested as a rapid fish spoilage indicator. Therefore, histamine biosensors based on immobilization of diamine oxidase (DAO) in photocurable poly (2-hydroxyethyl methacrylate) (photoHEMA) film was developed. Histamine was oxidized by immobilized DAO at 0.35 volt on the surface of carbon-paste screen-printed electrode (SPE) versus conventional Ag/AgCl reference, and with platinum rod as a counter electrode, which named as macro electrode system histamine biosensor. No leaching of the immobilized DAO was observed during histamine detection using the biosensor. The optimized histamine biosensor displayed a linear response over the range of 0 to 60 ppm histamine with correlation coefficient (R2) equals to 0.9946 (RSD < 11.19%). The sensitivity obtained was 5.56 nA ppm-1 and the limit of detection was 0.65 ppm of histamine with the response time of 50 seconds. The histamine biosensor exhibited repeatability and reproducibility characteristic with RSD values equals to 14.06 and 7.80% (n = 10) respectively. The histamine biosensor was applied to determine histamine in tiger prawns (Penaeus monodon) and the results were agreeable with a conventional high performance liquid chromatography (HPLC) method, where a correlation of R2 = 0.9612 (Y = 0.9614 x + 5.5813) was obtained. The developed histamine biosensor showed recovery of added histamine in the range of 93.11 to 100.58%. Home made miniaturized histamine biosensor (30 mm x 10 mm) was then developed by screen-printed of carbon as working and counter electrodes together with Ag/AgCl reference electrode on the polyester substrate {named SPE (i)}. Miniaturized histamine biosensor with SPE (i) operated at 0.25 volt exhibited a linear range from 0 to 100 ppm of histamine with R2 = 0.9577 (RSD < 9%) and sensitivity of 0.03 nAppm-1 with the limit of detection of 2.46 ppm of histamine. The miniaturized histamine biosensor with a SPE (ii) was operated at 0.35 volt and it showed a linear range from 0 to 50 ppm histamine with R2 of 0.9766 (RSD < 16%) and sensitivity of 0.40 nAppm-1. The limit of detection of histamine was 4.64 ppm. The miniaturized SPE (i) was then modified with K3Fe(CN)6 and operated at 0.35 volt. This biosensor could detect the histamine in the linear range of 0 to 80 ppm with the R2 = 0.9931 and sensitivity 5.31 nAppm-1. The limit of detection for this modified histamine biosensor was 2.11 ppm histamine. Histamine 2006 Thesis http://psasir.upm.edu.my/id/eprint/5359/ http://psasir.upm.edu.my/id/eprint/5359/1/IB_2006_12.pdf application/pdf en public masters Universiti Putra Malaysia Histamine Institute Bioscience English
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
English
topic Histamine


spellingShingle Histamine


Ching, Mai Keow
Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
description Histamine levels have been suggested as a rapid fish spoilage indicator. Therefore, histamine biosensors based on immobilization of diamine oxidase (DAO) in photocurable poly (2-hydroxyethyl methacrylate) (photoHEMA) film was developed. Histamine was oxidized by immobilized DAO at 0.35 volt on the surface of carbon-paste screen-printed electrode (SPE) versus conventional Ag/AgCl reference, and with platinum rod as a counter electrode, which named as macro electrode system histamine biosensor. No leaching of the immobilized DAO was observed during histamine detection using the biosensor. The optimized histamine biosensor displayed a linear response over the range of 0 to 60 ppm histamine with correlation coefficient (R2) equals to 0.9946 (RSD < 11.19%). The sensitivity obtained was 5.56 nA ppm-1 and the limit of detection was 0.65 ppm of histamine with the response time of 50 seconds. The histamine biosensor exhibited repeatability and reproducibility characteristic with RSD values equals to 14.06 and 7.80% (n = 10) respectively. The histamine biosensor was applied to determine histamine in tiger prawns (Penaeus monodon) and the results were agreeable with a conventional high performance liquid chromatography (HPLC) method, where a correlation of R2 = 0.9612 (Y = 0.9614 x + 5.5813) was obtained. The developed histamine biosensor showed recovery of added histamine in the range of 93.11 to 100.58%. Home made miniaturized histamine biosensor (30 mm x 10 mm) was then developed by screen-printed of carbon as working and counter electrodes together with Ag/AgCl reference electrode on the polyester substrate {named SPE (i)}. Miniaturized histamine biosensor with SPE (i) operated at 0.25 volt exhibited a linear range from 0 to 100 ppm of histamine with R2 = 0.9577 (RSD < 9%) and sensitivity of 0.03 nAppm-1 with the limit of detection of 2.46 ppm of histamine. The miniaturized histamine biosensor with a SPE (ii) was operated at 0.35 volt and it showed a linear range from 0 to 50 ppm histamine with R2 of 0.9766 (RSD < 16%) and sensitivity of 0.40 nAppm-1. The limit of detection of histamine was 4.64 ppm. The miniaturized SPE (i) was then modified with K3Fe(CN)6 and operated at 0.35 volt. This biosensor could detect the histamine in the linear range of 0 to 80 ppm with the R2 = 0.9931 and sensitivity 5.31 nAppm-1. The limit of detection for this modified histamine biosensor was 2.11 ppm histamine.
format Thesis
qualification_level Master's degree
author Ching, Mai Keow
author_facet Ching, Mai Keow
author_sort Ching, Mai Keow
title Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
title_short Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
title_full Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
title_fullStr Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
title_full_unstemmed Development and Characterization of a Diamine Oxidase-Based Histamine Biosensor
title_sort development and characterization of a diamine oxidase-based histamine biosensor
granting_institution Universiti Putra Malaysia
granting_department Institute Bioscience
publishDate 2006
url http://psasir.upm.edu.my/id/eprint/5359/1/IB_2006_12.pdf
_version_ 1747810407918075904