Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events

This thesis presents low velocity impact testing and high velocity impact testing on fibreglass reinforced polymer. The materials used in this experiment are Type Cglass/ Epoxy 600 g/m² and Type E-glass/Epoxy 800 g/m². The ultimate objective of this research is to conduct an experimental investiga...

Full description

Saved in:
Bibliographic Details
Main Author: Safri, Syafiqah Nur Azrie
Format: Thesis
Language:English
Published: 2014
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/64182/1/FK%202014%20115IR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.64182
record_format uketd_dc
spelling my-upm-ir.641822018-06-06T07:18:55Z Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events 2014-11 Safri, Syafiqah Nur Azrie This thesis presents low velocity impact testing and high velocity impact testing on fibreglass reinforced polymer. The materials used in this experiment are Type Cglass/ Epoxy 600 g/m² and Type E-glass/Epoxy 800 g/m². The ultimate objective of this research is to conduct an experimental investigation using low velocity impact testing and high velocity impact testing to detect and quantify impact damage for Glass Fibre Reinforced Polymer Type C-glass/Epoxy 600 g/m² and Type Eglass/Epoxy 800 g/m² plate. The purpose of this research is to choose the best material for structural application by comparing the mechanical properties and damage characteristics of GFRP Type C-glass/Epoxy 600 g/m² and Type Eglass/Epoxy 800 g/m². The experimental results of low-energy drop-weight impact tests on woven-roving Glass Fibre Reinforced Polymer (GFRP) type C-glass/Epoxy 600 g/m² and Type Eglass/ Epoxy 800 g/m² are presented. The effects of specimen thickness based on the number of plies and impact energy are investigated. Impact damage and response was observed for eight levels of impact energies, 6, 12, 18, 24, 30, 36, 42 and 48 J. From the experimental studies, it can be concluded that for each type of GFRP, the impact energy showed excellent correlation with the impact response. The difference in the number of plies fabricated and the mechanical properties for both types of GFRP do affect the impact response and impact damage of the specimens tested. The experimental results of the high velocity impact test using a Single Stage Gas Gun (SSGG) show that both types of GFRP exhibit damage in terms of fibre cracking, and fibre pull out after being tested with four different gas gun pressures. Before fibre failure occurs, they undergo matrix cracking and delamination processes first. As the gas gun pressure increases, the initial velocity of the projectile increases,the projectile kinetic energy increases, the maximum force exerted on the specimen increases, and the energy absorbed by the specimen also increases. Most of the impacted specimens show that GFRP type E-glass/Epoxy 800 g/m² experienced a smaller damage area compared to type C-glass/Epoxy 600 g/m². From the test, the effect of the shape of the projectile, the target thickness and the gas gun pressure affected the performance of GFRP. It can be concluded that GFRP type E-glass/Epoxy 800 g/m² is stronger compared to GFRP type C-glass/Epoxy 600 g/m² since it has more fibre volume since it is higher in density and has good mechanical properties. Therefore, GFRP type E-glass/Epoxy 800 g/m² is recommended to be used in structural applications. Glass fibers Polymers 2014-11 Thesis http://psasir.upm.edu.my/id/eprint/64182/ http://psasir.upm.edu.my/id/eprint/64182/1/FK%202014%20115IR.pdf text en public masters Universiti Putra Malaysia Glass fibers Polymers
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
topic Glass fibers
Polymers

spellingShingle Glass fibers
Polymers

Safri, Syafiqah Nur Azrie
Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
description This thesis presents low velocity impact testing and high velocity impact testing on fibreglass reinforced polymer. The materials used in this experiment are Type Cglass/ Epoxy 600 g/m² and Type E-glass/Epoxy 800 g/m². The ultimate objective of this research is to conduct an experimental investigation using low velocity impact testing and high velocity impact testing to detect and quantify impact damage for Glass Fibre Reinforced Polymer Type C-glass/Epoxy 600 g/m² and Type Eglass/Epoxy 800 g/m² plate. The purpose of this research is to choose the best material for structural application by comparing the mechanical properties and damage characteristics of GFRP Type C-glass/Epoxy 600 g/m² and Type Eglass/Epoxy 800 g/m². The experimental results of low-energy drop-weight impact tests on woven-roving Glass Fibre Reinforced Polymer (GFRP) type C-glass/Epoxy 600 g/m² and Type Eglass/ Epoxy 800 g/m² are presented. The effects of specimen thickness based on the number of plies and impact energy are investigated. Impact damage and response was observed for eight levels of impact energies, 6, 12, 18, 24, 30, 36, 42 and 48 J. From the experimental studies, it can be concluded that for each type of GFRP, the impact energy showed excellent correlation with the impact response. The difference in the number of plies fabricated and the mechanical properties for both types of GFRP do affect the impact response and impact damage of the specimens tested. The experimental results of the high velocity impact test using a Single Stage Gas Gun (SSGG) show that both types of GFRP exhibit damage in terms of fibre cracking, and fibre pull out after being tested with four different gas gun pressures. Before fibre failure occurs, they undergo matrix cracking and delamination processes first. As the gas gun pressure increases, the initial velocity of the projectile increases,the projectile kinetic energy increases, the maximum force exerted on the specimen increases, and the energy absorbed by the specimen also increases. Most of the impacted specimens show that GFRP type E-glass/Epoxy 800 g/m² experienced a smaller damage area compared to type C-glass/Epoxy 600 g/m². From the test, the effect of the shape of the projectile, the target thickness and the gas gun pressure affected the performance of GFRP. It can be concluded that GFRP type E-glass/Epoxy 800 g/m² is stronger compared to GFRP type C-glass/Epoxy 600 g/m² since it has more fibre volume since it is higher in density and has good mechanical properties. Therefore, GFRP type E-glass/Epoxy 800 g/m² is recommended to be used in structural applications.
format Thesis
qualification_level Master's degree
author Safri, Syafiqah Nur Azrie
author_facet Safri, Syafiqah Nur Azrie
author_sort Safri, Syafiqah Nur Azrie
title Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
title_short Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
title_full Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
title_fullStr Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
title_full_unstemmed Damage detection and characterization in C-glass and E-glass fibre-reinforced polymer due to low and high velocity impact events
title_sort damage detection and characterization in c-glass and e-glass fibre-reinforced polymer due to low and high velocity impact events
granting_institution Universiti Putra Malaysia
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/64182/1/FK%202014%20115IR.pdf
_version_ 1747812290570223616