Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements

Surface Electromyography (SEMG) is a technique to detect and monitor the muscles contraction during movements. Applying SEMG signal has difficulties due to complexity nature of this signal. Different type of noise like location of electrodes can affect SEMG signal during data acquisition. Electrode...

Full description

Saved in:
Bibliographic Details
Main Author: Zadeh, Hossein Ghapanchi
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/70479/1/FK%202016%2086%20IR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.70479
record_format uketd_dc
spelling my-upm-ir.704792019-08-21T04:02:43Z Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements 2016-02 Zadeh, Hossein Ghapanchi Surface Electromyography (SEMG) is a technique to detect and monitor the muscles contraction during movements. Applying SEMG signal has difficulties due to complexity nature of this signal. Different type of noise like location of electrodes can affect SEMG signal during data acquisition. Electrode location can significantly important to conquer different type of noises during data collection. There are two ways to overcome this difficulty; 1) finding the best electrode position and 2) finding inter-electrode distance. To find the best electrode location in bipolar recording mode, it was designed and implemented a 6 channel SEMG acquisition system to detect and acquire the upper limb muscles’ SEMG signal. After that, the present study investigated electrode position and inter-electrode distance (IED) for wrist movements over forearm muscles. This study is based on the muscle physiology such as origin, innervation zone (IZ) and tendon zone (TZ) location. Three different electrode positions and three different IED are investigated over thirty volunteers participated during seven daily wrist movements such as wrist extension, flexion, radial deviation, ulnar deviation, wrist rotation and fingers extension and flexion. To find out the best electrode position, the collected signal were analyzed in time and frequency domain. The best electrode location selected where SEMG signal had higher value in time and frequency domain (Mean Absolute Value, Root Mean Square, Power Spectra Density) with lower cross-talk value (Cross-Correlation). The results show a significant differences between various electrode positions in both time and frequency domain. This study recommends the best electrode position over FCR, ECR and ED muscles near muscle origin and IZ with 40mm IED. The best electrode position for ECU and FCU recommend between muscle origin and IZ with 20mm IED. This study also suggests the electrode site for FD muscle is between IZ and TZ with 20mm IED. The presented method should be observed as an important step in every SEMG application and research to guarantee the signal quality. Electromyography Electrodes - Therapeutic use Time-series analysis 2016-02 Thesis http://psasir.upm.edu.my/id/eprint/70479/ http://psasir.upm.edu.my/id/eprint/70479/1/FK%202016%2086%20IR.pdf text en public masters Universiti Putra Malaysia Electromyography Electrodes - Therapeutic use Time-series analysis
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
topic Electromyography
Electrodes - Therapeutic use
Time-series analysis
spellingShingle Electromyography
Electrodes - Therapeutic use
Time-series analysis
Zadeh, Hossein Ghapanchi
Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
description Surface Electromyography (SEMG) is a technique to detect and monitor the muscles contraction during movements. Applying SEMG signal has difficulties due to complexity nature of this signal. Different type of noise like location of electrodes can affect SEMG signal during data acquisition. Electrode location can significantly important to conquer different type of noises during data collection. There are two ways to overcome this difficulty; 1) finding the best electrode position and 2) finding inter-electrode distance. To find the best electrode location in bipolar recording mode, it was designed and implemented a 6 channel SEMG acquisition system to detect and acquire the upper limb muscles’ SEMG signal. After that, the present study investigated electrode position and inter-electrode distance (IED) for wrist movements over forearm muscles. This study is based on the muscle physiology such as origin, innervation zone (IZ) and tendon zone (TZ) location. Three different electrode positions and three different IED are investigated over thirty volunteers participated during seven daily wrist movements such as wrist extension, flexion, radial deviation, ulnar deviation, wrist rotation and fingers extension and flexion. To find out the best electrode position, the collected signal were analyzed in time and frequency domain. The best electrode location selected where SEMG signal had higher value in time and frequency domain (Mean Absolute Value, Root Mean Square, Power Spectra Density) with lower cross-talk value (Cross-Correlation). The results show a significant differences between various electrode positions in both time and frequency domain. This study recommends the best electrode position over FCR, ECR and ED muscles near muscle origin and IZ with 40mm IED. The best electrode position for ECU and FCU recommend between muscle origin and IZ with 20mm IED. This study also suggests the electrode site for FD muscle is between IZ and TZ with 20mm IED. The presented method should be observed as an important step in every SEMG application and research to guarantee the signal quality.
format Thesis
qualification_level Master's degree
author Zadeh, Hossein Ghapanchi
author_facet Zadeh, Hossein Ghapanchi
author_sort Zadeh, Hossein Ghapanchi
title Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
title_short Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
title_full Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
title_fullStr Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
title_full_unstemmed Influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
title_sort influence of surface electromyography electrode placement on signal accuracy at forearm muscles during wrist movements
granting_institution Universiti Putra Malaysia
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/70479/1/FK%202016%2086%20IR.pdf
_version_ 1747812847681798144