Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline

Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose...

Full description

Saved in:
Bibliographic Details
Main Author: Hassan, Muhammad Hishar
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.75302
record_format uketd_dc
spelling my-upm-ir.753022019-10-17T08:27:55Z Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline 2016-09 Hassan, Muhammad Hishar Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose (F-18 FDG) as there were few studies demonstrated the use of F-18 FDG was pointless in prostate cancer imaging. Thus, this current study presents development of convenient quality control analysis method and improvement performed on the azeotropic drying of no-carrier-added (n.c.a.) F-18 Fluorine to increase the F-18 Fluorocholine (F-18 FCH) radiochemical yield. From these studies, a convenient, efficient and reliable method for quality control analysis of F-18 FCH was successfully developed and validated to comply all the release criteria even in a limited equipment set-up. As most of the equipment set-up in the quality control laboratory in the present study was meant for the routine quality control analysis of F-18 FDG, several parameters were changed in order to adapt to the F-18 FCH quality control method without affecting the routine quality control analysis of F-18 FDG. The synthesis of F-18 FCH was successfully performed on a commercial synthesis module, GE TracerLab MxFDG with fairly good radiochemical yields, between 5 to 15%, which decay is not corrected. Interestingly, the finding from this study shows the potential of improvement on the azeotropic drying condition of n.c.a F-18 Fluorine as a preferred technique to improve the radiochemical yield of F-18 FCH. Radiochemistry Choline Quality Control 2016-09 Thesis http://psasir.upm.edu.my/id/eprint/75302/ http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf text en public masters Universiti Putra Malaysia Radiochemistry Choline Quality Control
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
topic Radiochemistry
Choline
Quality Control
spellingShingle Radiochemistry
Choline
Quality Control
Hassan, Muhammad Hishar
Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
description Prostate cancer continues to be the most prevalent cancer in men in Malaysia. It is anticipated that the number of prostate cancer sufferers’ will increase in future. In the case of Positron Emission Tomography / Computed Tomography (PET/CT), clinicians cannot solely rely on F-18 Fluorodeoxyglucose (F-18 FDG) as there were few studies demonstrated the use of F-18 FDG was pointless in prostate cancer imaging. Thus, this current study presents development of convenient quality control analysis method and improvement performed on the azeotropic drying of no-carrier-added (n.c.a.) F-18 Fluorine to increase the F-18 Fluorocholine (F-18 FCH) radiochemical yield. From these studies, a convenient, efficient and reliable method for quality control analysis of F-18 FCH was successfully developed and validated to comply all the release criteria even in a limited equipment set-up. As most of the equipment set-up in the quality control laboratory in the present study was meant for the routine quality control analysis of F-18 FDG, several parameters were changed in order to adapt to the F-18 FCH quality control method without affecting the routine quality control analysis of F-18 FDG. The synthesis of F-18 FCH was successfully performed on a commercial synthesis module, GE TracerLab MxFDG with fairly good radiochemical yields, between 5 to 15%, which decay is not corrected. Interestingly, the finding from this study shows the potential of improvement on the azeotropic drying condition of n.c.a F-18 Fluorine as a preferred technique to improve the radiochemical yield of F-18 FCH.
format Thesis
qualification_level Master's degree
author Hassan, Muhammad Hishar
author_facet Hassan, Muhammad Hishar
author_sort Hassan, Muhammad Hishar
title Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_short Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_full Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_fullStr Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_full_unstemmed Development of convenient quality control analysis method and improvement on the radiochemical yield using F-18-Labelled choline
title_sort development of convenient quality control analysis method and improvement on the radiochemical yield using f-18-labelled choline
granting_institution Universiti Putra Malaysia
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/75302/1/FPSK%28M%29%202016%2027%20IR.pdf
_version_ 1747813026833104896