Numerical study on effect of vortex generator for t-junction pipe flow

Application of Computational fluid dynamics (CFD) in studying T-Junction water pipe flow have been growing steadily. This is due to the fact that experimental work will cost more time and money. In Kuwait however, the CFD tool is not fully utilised in the T- Junction case due to lack experts to...

Full description

Saved in:
Bibliographic Details
Main Author: Alazemi, Hamad R Dh A S
Format: Thesis
Language:English
Published: 2019
Subjects:
Online Access:http://psasir.upm.edu.my/id/eprint/85393/1/FK%202019%20149%20-%20ir.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-upm-ir.85393
record_format uketd_dc
spelling my-upm-ir.853932021-12-30T02:25:57Z Numerical study on effect of vortex generator for t-junction pipe flow 2019-08 Alazemi, Hamad R Dh A S Application of Computational fluid dynamics (CFD) in studying T-Junction water pipe flow have been growing steadily. This is due to the fact that experimental work will cost more time and money. In Kuwait however, the CFD tool is not fully utilised in the T- Junction case due to lack experts to perform the CFD work. The current work focused on the CFD simulation on the T-Junction water pipe system that is available in Kuwait. The objective of the work is to investigate the fundamental physical mixing effects of the Kuwaiti T-Junction pipe and investigate the effects of the flow control device inside the T-Junction. The RANS equation was used as the governing equation. The standard k- epsilon model will be used for the turbulent flow of the water pipe. Second order discretization method was used to solve the non-linear RANS equations. The CFD results have been validated with the published experimental data with good agreement. From the baseline simulation, it is found that the physics of water flow shows that there is significant reverse flow at the downstream of the T-junction pipe. From the parametric study, three cases have been tested namely case with two vortex generators, four vortex generators, and eight vortex generators. From the results, it was found that the case with four vortex generators outperformed the other cases. The area of the reverse flow have been decreased significantly. Another parametric study was the size of the vortex generator. It was found that the best size was the 75 mm. The last parametric study was the magnitude of the water pipe flow. From the results, it was found that the vortex generator performed the best at the magnitude of 5m/s. Fluid dynamics - Computer programs Vortex generators Fluid dynamics 2019-08 Thesis http://psasir.upm.edu.my/id/eprint/85393/ http://psasir.upm.edu.my/id/eprint/85393/1/FK%202019%20149%20-%20ir.pdf text en public doctoral Universiti Putra Malaysia Fluid dynamics - Computer programs Vortex generators Fluid dynamics Ahmad, Kamarul Arifin
institution Universiti Putra Malaysia
collection PSAS Institutional Repository
language English
advisor Ahmad, Kamarul Arifin
topic Fluid dynamics - Computer programs
Vortex generators
Fluid dynamics
spellingShingle Fluid dynamics - Computer programs
Vortex generators
Fluid dynamics
Alazemi, Hamad R Dh A S
Numerical study on effect of vortex generator for t-junction pipe flow
description Application of Computational fluid dynamics (CFD) in studying T-Junction water pipe flow have been growing steadily. This is due to the fact that experimental work will cost more time and money. In Kuwait however, the CFD tool is not fully utilised in the T- Junction case due to lack experts to perform the CFD work. The current work focused on the CFD simulation on the T-Junction water pipe system that is available in Kuwait. The objective of the work is to investigate the fundamental physical mixing effects of the Kuwaiti T-Junction pipe and investigate the effects of the flow control device inside the T-Junction. The RANS equation was used as the governing equation. The standard k- epsilon model will be used for the turbulent flow of the water pipe. Second order discretization method was used to solve the non-linear RANS equations. The CFD results have been validated with the published experimental data with good agreement. From the baseline simulation, it is found that the physics of water flow shows that there is significant reverse flow at the downstream of the T-junction pipe. From the parametric study, three cases have been tested namely case with two vortex generators, four vortex generators, and eight vortex generators. From the results, it was found that the case with four vortex generators outperformed the other cases. The area of the reverse flow have been decreased significantly. Another parametric study was the size of the vortex generator. It was found that the best size was the 75 mm. The last parametric study was the magnitude of the water pipe flow. From the results, it was found that the vortex generator performed the best at the magnitude of 5m/s.
format Thesis
qualification_level Doctorate
author Alazemi, Hamad R Dh A S
author_facet Alazemi, Hamad R Dh A S
author_sort Alazemi, Hamad R Dh A S
title Numerical study on effect of vortex generator for t-junction pipe flow
title_short Numerical study on effect of vortex generator for t-junction pipe flow
title_full Numerical study on effect of vortex generator for t-junction pipe flow
title_fullStr Numerical study on effect of vortex generator for t-junction pipe flow
title_full_unstemmed Numerical study on effect of vortex generator for t-junction pipe flow
title_sort numerical study on effect of vortex generator for t-junction pipe flow
granting_institution Universiti Putra Malaysia
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/85393/1/FK%202019%20149%20-%20ir.pdf
_version_ 1747813537145683968