Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials
This research is carried out mainly to study the defect by comparing thermal images obtained from PPE setup and dual-beam mode-mismatched thermal lens method setup. The laser beam is optimized first to select the most suitable laser beam for thermal imaging process for PPE setup and dual-beam mo...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2019
|
Subjects: | |
Online Access: | http://psasir.upm.edu.my/id/eprint/90035/1/FS%202020%2010%20ir.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-upm-ir.90035 |
---|---|
record_format |
uketd_dc |
spelling |
my-upm-ir.900352021-12-03T01:15:22Z Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials 2019-12 Ting, Lee Mon This research is carried out mainly to study the defect by comparing thermal images obtained from PPE setup and dual-beam mode-mismatched thermal lens method setup. The laser beam is optimized first to select the most suitable laser beam for thermal imaging process for PPE setup and dual-beam mode-mismatched thermal lens method setup. Blue laser is chosen as the main laser source for thermal imaging process. Thermal imaging process is performed using PPE setup and dual-beam modemismatched thermal lens method setup to obtain the thermal images for samples of no defect, crack defect, line defect and hole defect. Comparison between thermal images obtained from PPE setup, two mirrors dual-beam mode-mismatched thermal lens setup and one mirror dual-beam mode-mismatched thermal lens setup are performed. Thermal images from PPE show the most stable results, two mirrors dual-beam mode-mismatched thermal lens setup show slightly fluctuate thermal images but with better view for defect studying, whereas one mirror dual-beam mode-mismatched thermal lens setup show the most fluctuation thermal images with an easier in data collecting when compare to two mirror dual-beam mode-mismatched thermal lens setup. Imaging systems Photoelectricity 2019-12 Thesis http://psasir.upm.edu.my/id/eprint/90035/ http://psasir.upm.edu.my/id/eprint/90035/1/FS%202020%2010%20ir.pdf text en public masters Universiti Putra Malaysia Imaging systems Photoelectricity Sa’at, Nor Kamilah |
institution |
Universiti Putra Malaysia |
collection |
PSAS Institutional Repository |
language |
English |
advisor |
Sa’at, Nor Kamilah |
topic |
Imaging systems Photoelectricity |
spellingShingle |
Imaging systems Photoelectricity Ting, Lee Mon Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
description |
This research is carried out mainly to study the defect by comparing thermal
images obtained from PPE setup and dual-beam mode-mismatched thermal
lens method setup.
The laser beam is optimized first to select the most suitable laser beam for
thermal imaging process for PPE setup and dual-beam mode-mismatched
thermal lens method setup. Blue laser is chosen as the main laser source for
thermal imaging process.
Thermal imaging process is performed using PPE setup and dual-beam modemismatched
thermal lens method setup to obtain the thermal images for
samples of no defect, crack defect, line defect and hole defect.
Comparison between thermal images obtained from PPE setup, two mirrors
dual-beam mode-mismatched thermal lens setup and one mirror dual-beam
mode-mismatched thermal lens setup are performed. Thermal images from
PPE show the most stable results, two mirrors dual-beam mode-mismatched
thermal lens setup show slightly fluctuate thermal images but with better view
for defect studying, whereas one mirror dual-beam mode-mismatched thermal
lens setup show the most fluctuation thermal images with an easier in data
collecting when compare to two mirror dual-beam mode-mismatched thermal
lens setup. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Ting, Lee Mon |
author_facet |
Ting, Lee Mon |
author_sort |
Ting, Lee Mon |
title |
Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
title_short |
Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
title_full |
Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
title_fullStr |
Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
title_full_unstemmed |
Photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
title_sort |
photothermal imaging using photopyroelectric and dual-beam mode-mismatched thermal lens method for defect study on transparent materials |
granting_institution |
Universiti Putra Malaysia |
publishDate |
2019 |
url |
http://psasir.upm.edu.my/id/eprint/90035/1/FS%202020%2010%20ir.pdf |
_version_ |
1747813603317121024 |