Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques
Magnetic thin films based on the giant magnetoresistance (GMR) and colossal magnetoresistance (CMR) effects are currently being used as head sensor in the magnetic data storage technology. With the technological revolution in the magnetic recording world of last decades, a need of better and more...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English |
Published: |
2002
|
Subjects: | |
Online Access: | http://psasir.upm.edu.my/id/eprint/9526/1/FSAS_2002_56_A.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-upm-ir.9526 |
---|---|
record_format |
uketd_dc |
spelling |
my-upm-ir.95262012-08-27T05:05:55Z Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques 2002-11 Lim, Kean Pah Magnetic thin films based on the giant magnetoresistance (GMR) and colossal magnetoresistance (CMR) effects are currently being used as head sensor in the magnetic data storage technology. With the technological revolution in the magnetic recording world of last decades, a need of better and more sensitive magnetoresistance material arises for head sensing. In the first part of this work, a series of Ag-Fe-Co granular films with different composition and thickness had been fabricated onto microscope glass slides using RF magnetron sputtering system. The crystalline analysis show that the as-deposited films consist of <111> and <200> silver texture. Negative GMR values have been obtained and no tendency to saturate at any temperature has been observed. The experimental results show that the GMR value is governed by the composition, microstructure, thickness and temperature. Under an optimum condition, formation of the right shape and size of magnetic cluster in the matrix will cause rapid increase of the GMR value. Magnetoresistance. 2002-11 Thesis http://psasir.upm.edu.my/id/eprint/9526/ http://psasir.upm.edu.my/id/eprint/9526/1/FSAS_2002_56_A.pdf application/pdf en public phd doctoral Universiti Putra Malaysia Magnetoresistance. Faculty of Science and Environmental Studies English |
institution |
Universiti Putra Malaysia |
collection |
PSAS Institutional Repository |
language |
English English |
topic |
Magnetoresistance. |
spellingShingle |
Magnetoresistance. Lim, Kean Pah Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
description |
Magnetic thin films based on the giant magnetoresistance (GMR) and colossal
magnetoresistance (CMR) effects are currently being used as head sensor in the
magnetic data storage technology. With the technological revolution in the magnetic
recording world of last decades, a need of better and more sensitive
magnetoresistance material arises for head sensing. In the first part of this work, a
series of Ag-Fe-Co granular films with different composition and thickness had been
fabricated onto microscope glass slides using RF magnetron sputtering system. The
crystalline analysis show that the as-deposited films consist of <111> and <200>
silver texture. Negative GMR values have been obtained and no tendency to saturate
at any temperature has been observed. The experimental results show that the GMR
value is governed by the composition, microstructure, thickness and temperature.
Under an optimum condition, formation of the right shape and size of magnetic
cluster in the matrix will cause rapid increase of the GMR value. |
format |
Thesis |
qualification_name |
Doctor of Philosophy (PhD.) |
qualification_level |
Doctorate |
author |
Lim, Kean Pah |
author_facet |
Lim, Kean Pah |
author_sort |
Lim, Kean Pah |
title |
Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
title_short |
Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
title_full |
Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
title_fullStr |
Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
title_full_unstemmed |
Studies on Giant and Colossal Magnetoresistance of Alloy and Ceramic Prepared by RF Magnetron Sputtering and Pulsed Laser Ablation Techniques |
title_sort |
studies on giant and colossal magnetoresistance of alloy and ceramic prepared by rf magnetron sputtering and pulsed laser ablation techniques |
granting_institution |
Universiti Putra Malaysia |
granting_department |
Faculty of Science and Environmental Studies |
publishDate |
2002 |
url |
http://psasir.upm.edu.my/id/eprint/9526/1/FSAS_2002_56_A.pdf |
_version_ |
1747810973680402432 |