Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging

Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tis...

Full description

Saved in:
Bibliographic Details
Main Author: Zainon, Rafidah
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.31141
record_format uketd_dc
spelling my-usm-ep.311412017-12-11T03:48:50Z Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging 2008-08 Zainon, Rafidah QC1 Physics (General) Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tissue equivalent materials and radioactive source for dual-modality Positron Emission Tomography/Computed Tomography (PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU), mass attenuation coefficient, elemental composition analysis and structure analysis were performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA), CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray (SEMlEDX) respectively. Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas -Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing. 2008-08 Thesis http://eprints.usm.my/31141/ http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Fizik
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic QC1 Physics (General)
spellingShingle QC1 Physics (General)
Zainon, Rafidah
Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
description Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tissue equivalent materials and radioactive source for dual-modality Positron Emission Tomography/Computed Tomography (PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU), mass attenuation coefficient, elemental composition analysis and structure analysis were performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA), CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray (SEMlEDX) respectively. Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas -Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing.
format Thesis
qualification_level Master's degree
author Zainon, Rafidah
author_facet Zainon, Rafidah
author_sort Zainon, Rafidah
title Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_short Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_full Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_fullStr Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_full_unstemmed Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
title_sort design and fabrication of multipurpose smart phantom for positron emission tomography/computed tomography imaging
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Sains Fizik
publishDate 2008
url http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf
_version_ 1747820397039976448