Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging
Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tis...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2008
|
Subjects: | |
Online Access: | http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my-usm-ep.31141 |
---|---|
record_format |
uketd_dc |
spelling |
my-usm-ep.311412017-12-11T03:48:50Z Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging 2008-08 Zainon, Rafidah QC1 Physics (General) Phantom studies are an important part in medical imaging as it can evaluate the performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of this study is to, design, fabricate and develop a multipurpose smart phantom which includes the internal structures, water, human tissue equivalent materials and radioactive source for dual-modality Positron Emission Tomography/Computed Tomography (PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU), mass attenuation coefficient, elemental composition analysis and structure analysis were performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA), CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray (SEMlEDX) respectively. Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas -Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing. 2008-08 Thesis http://eprints.usm.my/31141/ http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Sains Fizik |
institution |
Universiti Sains Malaysia |
collection |
USM Institutional Repository |
language |
English |
topic |
QC1 Physics (General) |
spellingShingle |
QC1 Physics (General) Zainon, Rafidah Design And Fabrication Of Multipurpose Smart Phantom For Positron Emission Tomography/Computed Tomography Imaging |
description |
Phantom studies are an important part in medical imaging as it can evaluate the
performance and quality assurance (QA) test of dual-modality PET/CT. The purpose of
this study is to, design, fabricate and develop a multipurpose smart phantom which
includes the internal structures, water, human tissue equivalent materials and radioactive
source for dual-modality Positron Emission Tomography/Computed Tomography
(PET/CT) imaging. In this study, experimental determination of Hounsfield units (HU),
mass attenuation coefficient, elemental composition analysis and structure analysis were
performed on phantom materials using PET/CT scanner, Multichannel Analyser (MCA),
CI-INS analyser and Scanning Electron MicroscopelEnergy Dispersive X-Ray
(SEMlEDX) respectively.
Kajian fantom adalah bahagian yang penting dalam pengimejan perubatan kerana ia
dapat menilai pedaksanaan dan ujian jaminan kualiti (QA) dwi-modaliti Tomografi
Pancaran Positronffomografi Berkomputer {PETtCT). Tujuan kajian ini adalah untuk
merekabentuk, memfabrikasi dan membangunkan fantom pintar pelbagai tujuan yang
termasuk struktur dalaman, air, bahan-bahan setara dengan tisu manusia dan sumber
radioaktif untuk pengimejan dwi-modaliti PETtCT. Dalam kajian ini, penentuan secara
eksperimen Unit Hounsfield (HU), pekali atenuasi jisim, analisis komposisi elemen dan
analisis struktur telah dilakukan terhadap bahan-bahan fantom menggunakan PETtCT
skan, Penganalisis Berbilang Saluran (MCA), Penganalis CHNS dan Pengimbas
-Mikroskop ElektronIKeselerakan Tenaga X-ray (SEMlEDX) masing-masing. |
format |
Thesis |
qualification_level |
Master's degree |
author |
Zainon, Rafidah |
author_facet |
Zainon, Rafidah |
author_sort |
Zainon, Rafidah |
title |
Design And Fabrication Of Multipurpose Smart Phantom
For Positron Emission Tomography/Computed Tomography
Imaging
|
title_short |
Design And Fabrication Of Multipurpose Smart Phantom
For Positron Emission Tomography/Computed Tomography
Imaging
|
title_full |
Design And Fabrication Of Multipurpose Smart Phantom
For Positron Emission Tomography/Computed Tomography
Imaging
|
title_fullStr |
Design And Fabrication Of Multipurpose Smart Phantom
For Positron Emission Tomography/Computed Tomography
Imaging
|
title_full_unstemmed |
Design And Fabrication Of Multipurpose Smart Phantom
For Positron Emission Tomography/Computed Tomography
Imaging
|
title_sort |
design and fabrication of multipurpose smart phantom
for positron emission tomography/computed tomography
imaging |
granting_institution |
Universiti Sains Malaysia |
granting_department |
Pusat Pengajian Sains Fizik |
publishDate |
2008 |
url |
http://eprints.usm.my/31141/1/RAFIDAH_BINTI_ZAINON.pdf |
_version_ |
1747820397039976448 |