Optimization of a low wind speed horrizontal axis wind turbine generator system.

Most commercial wind turbines are designed for high wind speeds (>10m/s) making them inappropriate for use in most areas of South East Asia which are located in a low wind speed region. The purpose of this work is to optimize a small wind turbine and generator for lower wind speeds prevalent in M...

Full description

Saved in:
Bibliographic Details
Main Author: Chong , Chuong Leong
Format: Thesis
Language:English
Published: 2011
Subjects:
Online Access:http://eprints.usm.my/41154/1/Chong_Chuong_Leong_24_Pages.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my-usm-ep.41154
record_format uketd_dc
spelling my-usm-ep.411542018-07-25T08:34:51Z Optimization of a low wind speed horrizontal axis wind turbine generator system. 2011 Chong , Chuong Leong TJ1-1570 Mechanical engineering and machinery Most commercial wind turbines are designed for high wind speeds (>10m/s) making them inappropriate for use in most areas of South East Asia which are located in a low wind speed region. The purpose of this work is to optimize a small wind turbine and generator for lower wind speeds prevalent in Malaysia. An axial flux permanent magnet generator was designed and developed. This generator was optimized to achieve high power at low rotational speeds. The generator is capable of producing 200W of electrical power at a rotational speed of 300rpm. Wind turbine is investigated as a function of angle of attack and load on a 4.6 m diameter 3–blade horizontal axis wind turbine. The wooden blades used a NACA (National Advisory Committee for Aeronautics) 4415 profile. A total of 16 various combinations of load and attack angle were carried out. These tests were performed with the turbine mounted atop of the Mechanical Engineering building which is located in a representative low wind speed region. A data logger was used to collect power, temperature, wind speed and wind direction data. In a 2 month study, the average wind speed was 0.2m/s with peak power wind speed of 3m/s and a maximum wind speed recorded was 9 m/s. Average daily energy production of 150Wh was recorded. A 9 degree angle attack and 6 ohm load produced the maximum power of 200W at 4.2m/s wind speed. The coefficient of performance of the wind turbine was measured to be 0.27. 2011 Thesis http://eprints.usm.my/41154/ http://eprints.usm.my/41154/1/Chong_Chuong_Leong_24_Pages.pdf application/pdf en public masters Universiti Sains Malaysia Pusat Pengajian Kejuruteraan Mekanik
institution Universiti Sains Malaysia
collection USM Institutional Repository
language English
topic TJ1-1570 Mechanical engineering and machinery
spellingShingle TJ1-1570 Mechanical engineering and machinery
Chong , Chuong Leong
Optimization of a low wind speed horrizontal axis wind turbine generator system.
description Most commercial wind turbines are designed for high wind speeds (>10m/s) making them inappropriate for use in most areas of South East Asia which are located in a low wind speed region. The purpose of this work is to optimize a small wind turbine and generator for lower wind speeds prevalent in Malaysia. An axial flux permanent magnet generator was designed and developed. This generator was optimized to achieve high power at low rotational speeds. The generator is capable of producing 200W of electrical power at a rotational speed of 300rpm. Wind turbine is investigated as a function of angle of attack and load on a 4.6 m diameter 3–blade horizontal axis wind turbine. The wooden blades used a NACA (National Advisory Committee for Aeronautics) 4415 profile. A total of 16 various combinations of load and attack angle were carried out. These tests were performed with the turbine mounted atop of the Mechanical Engineering building which is located in a representative low wind speed region. A data logger was used to collect power, temperature, wind speed and wind direction data. In a 2 month study, the average wind speed was 0.2m/s with peak power wind speed of 3m/s and a maximum wind speed recorded was 9 m/s. Average daily energy production of 150Wh was recorded. A 9 degree angle attack and 6 ohm load produced the maximum power of 200W at 4.2m/s wind speed. The coefficient of performance of the wind turbine was measured to be 0.27.
format Thesis
qualification_level Master's degree
author Chong , Chuong Leong
author_facet Chong , Chuong Leong
author_sort Chong , Chuong Leong
title Optimization of a low wind speed horrizontal axis wind turbine generator system.
title_short Optimization of a low wind speed horrizontal axis wind turbine generator system.
title_full Optimization of a low wind speed horrizontal axis wind turbine generator system.
title_fullStr Optimization of a low wind speed horrizontal axis wind turbine generator system.
title_full_unstemmed Optimization of a low wind speed horrizontal axis wind turbine generator system.
title_sort optimization of a low wind speed horrizontal axis wind turbine generator system.
granting_institution Universiti Sains Malaysia
granting_department Pusat Pengajian Kejuruteraan Mekanik
publishDate 2011
url http://eprints.usm.my/41154/1/Chong_Chuong_Leong_24_Pages.pdf
_version_ 1747820884127645696