Correlation of vascular stenosis with hemodialysis parameters in native arterio-venous fistula (AVF), pre and post percutaneous transluminal angioplasty (PTA)

Introduction: Stenosis and thrombosis of Arterio-Venous Fistula (AVF) has been an ongoing problem in hemodialysis patients. Early treatment by Percutaneous Transluminal Angioplasty (PTA) helps in maintaining AVF patency. However, how much PTA would improve the hemodialysis function was still ques...

全面介紹

Saved in:
書目詳細資料
主要作者: Halim, Ani Darwina
格式: Thesis
語言:English
出版: 2016
主題:
在線閱讀:http://eprints.usm.my/41568/1/Dr._Ani_Darwina_Abd_Halim-24_pages.pdf
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Introduction: Stenosis and thrombosis of Arterio-Venous Fistula (AVF) has been an ongoing problem in hemodialysis patients. Early treatment by Percutaneous Transluminal Angioplasty (PTA) helps in maintaining AVF patency. However, how much PTA would improve the hemodialysis function was still questionable and only few literatures discussed on this matter. Hence, we performed a study on “Correlation of Vascular Stenosis with Hemodialysis Parameters in Native Arteriovenous Fistula (AVF), Pre and Post Percutaneous Transluminal Angioplasty”. Objective: To determine association between percentage of residual stenosis with hemodialysis success. Methodology: A total of 47 patients underwent Percutaneous Transluminal Angioplasty (PTA) in AMIEN Unit HUSM from June 2014 till October 2015; 14 were excluded and 19 lost to follow up leaving 14 subjects to study. All measurements of stenosis diameter were made from the PACS system whereas hemodialysis parameters were gathered through phone call to the subjects’ regular hemodialysis centre. Results: This study has revealed a weak correlation between percentage of stenosis with blood pump flow rate (Qb) in pre and post PTA. No correlation between percentage of stenosis with venous dialysis pressure (Vp) in pre and post PTA. The achieved technical success was 57.1% (P = 0.001). Conclusion: There is weak correlation between degree of stenosis with blood pump flow rate (Qb) but not observed in venous dialysis pressure (Vp).